This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicabi...This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation.展开更多
So far, numerous numerical studies have been conducted on the behavior of Composite Reinforced Concrete-Steel (RCS) beam-to-column connections. However, the lack of studies regarding the steel joist-concrete girder ...So far, numerous numerical studies have been conducted on the behavior of Composite Reinforced Concrete-Steel (RCS) beam-to-column connections. However, the lack of studies regarding the steel joist-concrete girder connection has yet to be addressed through comprehensive finite element methods to get an understanding of influential parameters. Hence, in this paper, composite connection of embedded steel joist in concrete girder is investigated with an appropriate finite element software, namely, ABAQUS. The validity of the proposed model is examined by the comparison made with the test data in literature. Results indicate that maximum bending capacity of the connection is achieved when embedment ratio is 1.78. Moreover, double web angles in the embedment region significantly reduce the embedment length required to achieve the maximum bending capacity. Finally, damage analyses show that bending capacity of concrete girder is slightly reduced in the connection zone.展开更多
基金supported by the Basic Science Research Program of the National Research Foundation of Korea (NRF) and funded by the Ministry of Education,Science and Technology (2011-0009227)
文摘This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation.
文摘So far, numerous numerical studies have been conducted on the behavior of Composite Reinforced Concrete-Steel (RCS) beam-to-column connections. However, the lack of studies regarding the steel joist-concrete girder connection has yet to be addressed through comprehensive finite element methods to get an understanding of influential parameters. Hence, in this paper, composite connection of embedded steel joist in concrete girder is investigated with an appropriate finite element software, namely, ABAQUS. The validity of the proposed model is examined by the comparison made with the test data in literature. Results indicate that maximum bending capacity of the connection is achieved when embedment ratio is 1.78. Moreover, double web angles in the embedment region significantly reduce the embedment length required to achieve the maximum bending capacity. Finally, damage analyses show that bending capacity of concrete girder is slightly reduced in the connection zone.