期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
基于立体封装技术的复合电子系统模块应用
1
作者 占连样 王烈洋 +3 位作者 黄小虎 蒋晓华 李光 彭杰 《电子产品世界》 2014年第9期58-60,共3页
本文在SIP立体封装技术的基础上,设计了基于DSP、FPGA的复合电子系统模块。重点介绍了模块的功能构成及模块接口应用,为基于SIP小型化封装的复合电子系统(功能可订制)提供应用基础。
关键词 复合电子系统 RS422
下载PDF
Development of Chloride Electrode Coated Wire and Composite Systems for Determination Chloride Ion in Gunungkidul Spring Water
2
作者 Suyanta Sunarto Susila Kristianingrum Tanti Hidayah 《Journal of Chemistry and Chemical Engineering》 2014年第7期662-667,共6页
The purpose of this research was to fmd out effectiveness of chloride solid membrane electrode of coated wire system compared to solid membrane electrode of composite system, the Nernstian response and character's po... The purpose of this research was to fmd out effectiveness of chloride solid membrane electrode of coated wire system compared to solid membrane electrode of composite system, the Nernstian response and character's potential response (detection limit, selectivity and response time). The chloride ISEs (ion selective electrodes) in this research were the solid membrane chloride ISEs based AgC1. There were two types of chloride ISEs that were developed, namely the chloride ISEs of coated wire and composite systems. Both types of electrodes were characterized. The selectivity was done by comparing Esel of the chloride standard solutions and Esel of the interference ions (Br- and I-). The measurement of chloride ions in water samples was done by using the coated wire chloride ISE, the composite chloride ISE and the Mohr method. We compared the result of the two chloride ISE methods to that of standard method for chloride determination (Mohr) by using F-test and Post Hoc Test LSD (least significant difference) and Duncan. Analysis by using F-test and Post Hoc Test (LSD and Duncan) and characterization results of both the methods showed that coated wire chloride ISE was more effective compared to composite chloride ISE. Nemstian response was 59.83 mV/decade, linier range measurement was 10-1-10-5 M, limit detection was 1.23 × 10-5 M, response time along was 25 s and interfering ion was 10-4 M Br-. 展开更多
关键词 Chloride ISEs coated wire electrode composite electrode Gunungkidul spring water.
下载PDF
Assessment of nanocomposite photonic systems with the X-ray photoelectron spectroscopy
3
作者 L. Minati G. Speranza +3 位作者 M. Anderle M. Ferrari A. Chiasera G. C. Righini 《Optoelectronics Letters》 EI 2007年第3期192-194,共3页
The chemical compositions of Ag-Er co-doped phosphate and silicate glasses were investigated with X-ray photoelectron spectroscopy with the purpose to identify the chemical state of silver. The analysis of the Ag 3d c... The chemical compositions of Ag-Er co-doped phosphate and silicate glasses were investigated with X-ray photoelectron spectroscopy with the purpose to identify the chemical state of silver. The analysis of the Ag 3d core lines show the presence of nanometer-sized silver particles in each of the annealed samples,even if these Ag 3d lines appear to be very different from each other. We explain these results as a different interaction of silver with the two glasses matrix,which leads to a different nucleation rate of the Ag clusters. 展开更多
关键词 纳米复合子系统 评价 X线光电子光谱学 磷酸盐玻璃 硅酸盐玻璃 Ag-Er共掺杂
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部