Location of the heavily loaded building on the ground of the small load capacity requires application of the appropriate foundation structure. The required foundation system is most often deep, it is expensive and its...Location of the heavily loaded building on the ground of the small load capacity requires application of the appropriate foundation structure. The required foundation system is most often deep, it is expensive and its cost increases significantly when the building is located in earthquake area or in mining damage sector. The proposed structural system of the combined foundation makes possible to design and to construct a very stable and relative inexpensive foundation structure, which can obtain an extremely large horizontal surface and which can be placed not deeply beneath the terrain level. It can be a very solid support structure for a tall building placed on very weak subsoil and at the same time located in seismic area. This system can be applied not only for new buildings but it can be used for the existing buildings and moreover for straighten of the inclined objects. Due to special arrangement of component parts the combined foundation possesses inherent features of a vibration damper, what is highly desirable if buildings have to be located in earthquake areas. When the aboveground storeys structure has some similar patterns with structural form of the combined foundation then the structural system of the whole building obtains coherent structural characteristics and it is called the combined structural system of the tall building. Suitable application of this system makes possible to design high-rise buildings having interesting and unique architectonic forms, what is presented on a selected example.展开更多
Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan.The analysis results show that this kind of composite wall panel works very w...Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan.The analysis results show that this kind of composite wall panel works very well,and can be regarded as a solid panel.The composite wall panel with a hidden frame is essential for bringing its effect on shear resistance into full play.Comprehensive analysis of the shear-resistant behavior of the composite wall panel suggests that the shear of the composite shear wall panel can be controlled by the cracking strength of the web shearing diagonal crack.展开更多
文摘Location of the heavily loaded building on the ground of the small load capacity requires application of the appropriate foundation structure. The required foundation system is most often deep, it is expensive and its cost increases significantly when the building is located in earthquake area or in mining damage sector. The proposed structural system of the combined foundation makes possible to design and to construct a very stable and relative inexpensive foundation structure, which can obtain an extremely large horizontal surface and which can be placed not deeply beneath the terrain level. It can be a very solid support structure for a tall building placed on very weak subsoil and at the same time located in seismic area. This system can be applied not only for new buildings but it can be used for the existing buildings and moreover for straighten of the inclined objects. Due to special arrangement of component parts the combined foundation possesses inherent features of a vibration damper, what is highly desirable if buildings have to be located in earthquake areas. When the aboveground storeys structure has some similar patterns with structural form of the combined foundation then the structural system of the whole building obtains coherent structural characteristics and it is called the combined structural system of the tall building. Suitable application of this system makes possible to design high-rise buildings having interesting and unique architectonic forms, what is presented on a selected example.
基金Project(50948036)supported by the National Natural Science Foundation of ChinaProject(2012H0028)supported by Key Scientific and Technological Planning Project of Fujian Province,China+2 种基金Projects(2013J01192,2013J01196)supported by Natural Science Foundation Planning Project of Fujian Province,ChinaProject(2013Z37)supported by Key Scientific and Technological Planning Project of Quanzhou City,ChinaProject(2014KJTD05)supported by Program for Scientific and Technological Innovation Team and Leading Talent of Huaqiao University,China
文摘Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan.The analysis results show that this kind of composite wall panel works very well,and can be regarded as a solid panel.The composite wall panel with a hidden frame is essential for bringing its effect on shear resistance into full play.Comprehensive analysis of the shear-resistant behavior of the composite wall panel suggests that the shear of the composite shear wall panel can be controlled by the cracking strength of the web shearing diagonal crack.