The frequency offset information is extracted from local pilot amplitude characteristics, which suffer much less distortion in frequency-selective fading channels than those utilizing frequency domain correlation tech...The frequency offset information is extracted from local pilot amplitude characteristics, which suffer much less distortion in frequency-selective fading channels than those utilizing frequency domain correlation techniques. Simulation shows that the performance of this scheme has better performance than the existing frequency domain pilot-based frequency offset detection scheme.展开更多
Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowinten...Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowintensity ultrasound stimulation on the proliferation and reproductivity of Hep G2 and 3T3 cells in vitro was examined with a 1.06 MHz-generator by changing the parameters(including intensity, pulse repetition frequency and duty cycle)in a wide range. Cell viability and reproductivity at different time after sonication were measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)and colony formation assay to indicate timerelated proliferation. The results illustrate that ultrasound irradiation at 0.4—0.8 W/cm^2 and high pulse repetition frequency(100 Hz)can facilitate cell proliferation, while above 0.8 W/cm^2 would resist it. The extent of resistance closely correlated with duty cycle and pulse repetition frequency. Resistance effect at low pulse repetition frequency(1 Hz)is greater than that at high pulse repetition frequency(100 Hz)and not time-related. The influence of high pulse repetition frequency is time-accumulated, indicating cellular process involved. These findings would provide valuable guidelines for the application of low-intensity ultrasound in stem cell transformation and tissue engineering.展开更多
A novel approach, which can handle ambiguous data from weak targets, is proposed within the randomized Hough transform track-before-detect(RHT-TBD) framework. The main idea is that, without the pre-detection and ambig...A novel approach, which can handle ambiguous data from weak targets, is proposed within the randomized Hough transform track-before-detect(RHT-TBD) framework. The main idea is that, without the pre-detection and ambiguity resolution step at each time step, the ambiguous measurements are mapped by the multiple hypothesis ranging(MHR) procedure. In this way, all the information, based on the relativity in time and pulse repetition frequency(PRF) domains, can be gathered among different PRFs and integrated over time via a batch procedure. The final step is to perform the RHT with all the extended measurements, and the ambiguous data is unfolded while the detection decision is confirmed at the end of the processing chain.Unlike classic methods, the new approach resolves the problem of range ambiguity and detects the true track for targets. Finally, its application is illustrated to analyze and compare the performance between the proposed approach and the existing approach. Simulation results exhibit the effectiveness of this approach.展开更多
文摘The frequency offset information is extracted from local pilot amplitude characteristics, which suffer much less distortion in frequency-selective fading channels than those utilizing frequency domain correlation techniques. Simulation shows that the performance of this scheme has better performance than the existing frequency domain pilot-based frequency offset detection scheme.
基金Supported by the Natural Science Foundation of Tianjin(No.12JCYBJC18300)
文摘Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowintensity ultrasound stimulation on the proliferation and reproductivity of Hep G2 and 3T3 cells in vitro was examined with a 1.06 MHz-generator by changing the parameters(including intensity, pulse repetition frequency and duty cycle)in a wide range. Cell viability and reproductivity at different time after sonication were measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)and colony formation assay to indicate timerelated proliferation. The results illustrate that ultrasound irradiation at 0.4—0.8 W/cm^2 and high pulse repetition frequency(100 Hz)can facilitate cell proliferation, while above 0.8 W/cm^2 would resist it. The extent of resistance closely correlated with duty cycle and pulse repetition frequency. Resistance effect at low pulse repetition frequency(1 Hz)is greater than that at high pulse repetition frequency(100 Hz)and not time-related. The influence of high pulse repetition frequency is time-accumulated, indicating cellular process involved. These findings would provide valuable guidelines for the application of low-intensity ultrasound in stem cell transformation and tissue engineering.
基金supported by National Natural Science Foundation of China (Grant Nos. 61179018, 61372027, 61501489)Special Foundation for Mountain Tai Scholars
文摘A novel approach, which can handle ambiguous data from weak targets, is proposed within the randomized Hough transform track-before-detect(RHT-TBD) framework. The main idea is that, without the pre-detection and ambiguity resolution step at each time step, the ambiguous measurements are mapped by the multiple hypothesis ranging(MHR) procedure. In this way, all the information, based on the relativity in time and pulse repetition frequency(PRF) domains, can be gathered among different PRFs and integrated over time via a batch procedure. The final step is to perform the RHT with all the extended measurements, and the ambiguous data is unfolded while the detection decision is confirmed at the end of the processing chain.Unlike classic methods, the new approach resolves the problem of range ambiguity and detects the true track for targets. Finally, its application is illustrated to analyze and compare the performance between the proposed approach and the existing approach. Simulation results exhibit the effectiveness of this approach.