The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental s...The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental system with the method of optical heterodyne, using the refraction light beam from a prism, and made the experiment. The experimental results are in accordance with the theoretical calculation. It is very useful in some particular case, such as in Negative- Index Materials(NIM), to verify the Doppler Effect with this method.展开更多
A numerical study has been carried out to investigate the effect of aspect ratio on heat transfer by natural convection of nanofluid taking Cu nano particles and the water as based fluid. The flow is laminar, steady s...A numerical study has been carried out to investigate the effect of aspect ratio on heat transfer by natural convection of nanofluid taking Cu nano particles and the water as based fluid. The flow is laminar, steady state, axisymmetric two-dimensional in a vertical cylindrical channel filled with porous media. Heat is generated uniformly along the center of the channel with its vertical surface remain with cooled constant wall temperature and insulated horizontal top and bottom surfaces. The governing equations which used are continuity, momentum and energy equations using Darcy law and Boussinesq's approximation which are transformed to dimensionless equations. The finite difference approach is used to obtain all the computational results using the MATLAB-7 program. The parameters affected on the system are Rayleigh number ranging within (10≤ Ra ≤ 103), aspect ratio (1 ≤ As 〈 5) and the volume fraction (0 ≤0 〈 0.2). The results obtained are presented graphically in the form of streamline and isotherm contour plots and the results show that as ~ increase from 0.01 to 0.2 the value of the mean Nusselt number increase 50.4% for Ra = 1,000.展开更多
Consensus methods have presented promising tools for improving the reliability of quantitative models in near-infrared(NIR) spectroscopic analysis.A strategy for improving the performance of consensus methods in multi...Consensus methods have presented promising tools for improving the reliability of quantitative models in near-infrared(NIR) spectroscopic analysis.A strategy for improving the performance of consensus methods in multivariate calibration of NIR spectra is proposed.In the approach,a subset of non-collinear variables is generated using successive projections algorithm(SPA) for each variable in the reduced spectra by uninformative variables elimination(UVE).Then sub-models are built using the variable subsets and the calibration subsets determined by Monte Carlo(MC) re-sampling,and the sub-model that produces minimal error in cross validation is selected as a member model.With repetition of the MC re-sampling,a series of member models are built and a consensus model is achieved by averaging all the member models.Since member models are built with the best variable subset and the randomly selected calibration subset,both the quality and the diversity of the member models are insured for the consensus model.Two NIR spectral datasets of tobacco lamina are used to investigate the proposed method.The superiority of the method in both accuracy and reliability is demonstrated.展开更多
文摘The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental system with the method of optical heterodyne, using the refraction light beam from a prism, and made the experiment. The experimental results are in accordance with the theoretical calculation. It is very useful in some particular case, such as in Negative- Index Materials(NIM), to verify the Doppler Effect with this method.
文摘A numerical study has been carried out to investigate the effect of aspect ratio on heat transfer by natural convection of nanofluid taking Cu nano particles and the water as based fluid. The flow is laminar, steady state, axisymmetric two-dimensional in a vertical cylindrical channel filled with porous media. Heat is generated uniformly along the center of the channel with its vertical surface remain with cooled constant wall temperature and insulated horizontal top and bottom surfaces. The governing equations which used are continuity, momentum and energy equations using Darcy law and Boussinesq's approximation which are transformed to dimensionless equations. The finite difference approach is used to obtain all the computational results using the MATLAB-7 program. The parameters affected on the system are Rayleigh number ranging within (10≤ Ra ≤ 103), aspect ratio (1 ≤ As 〈 5) and the volume fraction (0 ≤0 〈 0.2). The results obtained are presented graphically in the form of streamline and isotherm contour plots and the results show that as ~ increase from 0.01 to 0.2 the value of the mean Nusselt number increase 50.4% for Ra = 1,000.
基金supported by the National Natural Science Foundation of China (20835002)
文摘Consensus methods have presented promising tools for improving the reliability of quantitative models in near-infrared(NIR) spectroscopic analysis.A strategy for improving the performance of consensus methods in multivariate calibration of NIR spectra is proposed.In the approach,a subset of non-collinear variables is generated using successive projections algorithm(SPA) for each variable in the reduced spectra by uninformative variables elimination(UVE).Then sub-models are built using the variable subsets and the calibration subsets determined by Monte Carlo(MC) re-sampling,and the sub-model that produces minimal error in cross validation is selected as a member model.With repetition of the MC re-sampling,a series of member models are built and a consensus model is achieved by averaging all the member models.Since member models are built with the best variable subset and the randomly selected calibration subset,both the quality and the diversity of the member models are insured for the consensus model.Two NIR spectral datasets of tobacco lamina are used to investigate the proposed method.The superiority of the method in both accuracy and reliability is demonstrated.