The broad application of virtual reality (VR) to medicine has been of great value. The virtual surgery is one of technically difficult applications. With the expansion of the increasingly fine and complicated ear micr...The broad application of virtual reality (VR) to medicine has been of great value. The virtual surgery is one of technically difficult applications. With the expansion of the increasingly fine and complicated ear microsurgery, new methods are required to train the doctors. It is necessary and of practical significance to apply VR to the ear micro-operation, which is a functional operation with high precision and great difficulties. In this article, medical VR applications were reviewed. The application of VR to the ear microsurgery was discussed and the virtual ear microsurgery system was designed.展开更多
Objective To investigate the association between preoperative,operative,and postoperative factors and persistent pleural effusion after the extracardiac Fontan procedure. Methods Ninety-five consecutive patients diagn...Objective To investigate the association between preoperative,operative,and postoperative factors and persistent pleural effusion after the extracardiac Fontan procedure. Methods Ninety-five consecutive patients diagnosed with univentricular heart underwent extracardiac connection using Gore-Tax conduits at the Department of Children’s Heart Centre,Justus-Liebig-University Giessen in Germany from June 1996 to July 2007. The outcome measures were duration and volume of chest tube drainage after surgical intervention. The investigated factors included age and weight at the time of operation,anatomical diagnosis,preoperative oxygen saturation,mean pulmonary artery pressure,ventricular end-diastolic pressure,fenestration,cardiopulmonary bypass time,conduit size,postoperative pulmonary artery pressure,administration of angiotensin-converting enzyme inhibitors,and postoperative infection. Associations between these factors and persistent pleural effusion after the extracardiac Fontan procedure were analyzed. Results Every patient suffered postoperative effusion. The median duration of postoperative chest tube drainage was 9 days (range,3-69 days),and the median volume was 12 mL·kg-1·d-1 (range,2.0-37.5 mL·kg-1·d-1). Thirty-seven (38.9%) patients had pleural drainage for more than 15 days,and the volume in 35 (36.8%) patients exceeded 25 mL·kg-1·d-1. Nineteen (20%) patients required placement of additional chest tubes for re-accumulation of pleural effusion after removal of previous chest tubes. Fifteen (17.8%) patients were hospitalized again due to pleural effusion after discharge. The median length of hospital stay after the operation was 14 days (range,4-78 days). Multivariate analysis results showed that non-fenestration,low preoperative oxygen saturation,and postoperative infections were independent risk factors for prolonged duration of pleural drainage (P<0.05). Long cardiopulmonary bypass time,non-fenestration,small conduit size,and low preoperative oxygen saturation were independent risk factors for excessive volume of pleural drainage (P<0.05).Conclusions For reduing postoperative duration and volume of pleural drainage following Fontan procedure,it seems to be important to improve the preoperative oxygen saturation,use large size of conduit,shorten cardiopulmonary bypass time,and make fenestration during the operation,as well as avoid postoperative infections.展开更多
To investigated the hemostatic ability of the S and F1-10 methods in clinical and ex vivo studies. METHODSThe hemostatic abilities of the two methods were analyzed retrospectively in all six gastric endoscopic submuco...To investigated the hemostatic ability of the S and F1-10 methods in clinical and ex vivo studies. METHODSThe hemostatic abilities of the two methods were analyzed retrospectively in all six gastric endoscopic submucosal dissection cases. The treated vessel diameter, compressed vessel frequency, and bleeding frequency after cutting the vessels were noted by the recorded videos. The coagulation mechanism of the two power settings was evaluated using the data recording program and histological examination on macro- and microscopic levels in the ex vivo experiments using porcine tissues. RESULTSF1-10 method showed a significantly better hemostatic ability for vessels ≥ 2 mm in diameter and a trend of overall better coagulation effect, evaluated by the bleeding rate after cutting the vessels. F1-10 method could sustain electrical current longer and effectively coagulate the tissue wider and deeper than the S method in the porcine model. CONCLUSIONF1-10 method is suggested to achieve a stronger hemostatic effect than the S method in clinical procedures and ex vivo models.展开更多
基金The Scientific Research Fund of ShanghaiScience Committee( 0 3 411980 8) and the Science and TechnologySpecial Fund of Pudong New District( PKJ2 0 0 3 -4 1)
文摘The broad application of virtual reality (VR) to medicine has been of great value. The virtual surgery is one of technically difficult applications. With the expansion of the increasingly fine and complicated ear microsurgery, new methods are required to train the doctors. It is necessary and of practical significance to apply VR to the ear micro-operation, which is a functional operation with high precision and great difficulties. In this article, medical VR applications were reviewed. The application of VR to the ear microsurgery was discussed and the virtual ear microsurgery system was designed.
文摘Objective To investigate the association between preoperative,operative,and postoperative factors and persistent pleural effusion after the extracardiac Fontan procedure. Methods Ninety-five consecutive patients diagnosed with univentricular heart underwent extracardiac connection using Gore-Tax conduits at the Department of Children’s Heart Centre,Justus-Liebig-University Giessen in Germany from June 1996 to July 2007. The outcome measures were duration and volume of chest tube drainage after surgical intervention. The investigated factors included age and weight at the time of operation,anatomical diagnosis,preoperative oxygen saturation,mean pulmonary artery pressure,ventricular end-diastolic pressure,fenestration,cardiopulmonary bypass time,conduit size,postoperative pulmonary artery pressure,administration of angiotensin-converting enzyme inhibitors,and postoperative infection. Associations between these factors and persistent pleural effusion after the extracardiac Fontan procedure were analyzed. Results Every patient suffered postoperative effusion. The median duration of postoperative chest tube drainage was 9 days (range,3-69 days),and the median volume was 12 mL·kg-1·d-1 (range,2.0-37.5 mL·kg-1·d-1). Thirty-seven (38.9%) patients had pleural drainage for more than 15 days,and the volume in 35 (36.8%) patients exceeded 25 mL·kg-1·d-1. Nineteen (20%) patients required placement of additional chest tubes for re-accumulation of pleural effusion after removal of previous chest tubes. Fifteen (17.8%) patients were hospitalized again due to pleural effusion after discharge. The median length of hospital stay after the operation was 14 days (range,4-78 days). Multivariate analysis results showed that non-fenestration,low preoperative oxygen saturation,and postoperative infections were independent risk factors for prolonged duration of pleural drainage (P<0.05). Long cardiopulmonary bypass time,non-fenestration,small conduit size,and low preoperative oxygen saturation were independent risk factors for excessive volume of pleural drainage (P<0.05).Conclusions For reduing postoperative duration and volume of pleural drainage following Fontan procedure,it seems to be important to improve the preoperative oxygen saturation,use large size of conduit,shorten cardiopulmonary bypass time,and make fenestration during the operation,as well as avoid postoperative infections.
文摘To investigated the hemostatic ability of the S and F1-10 methods in clinical and ex vivo studies. METHODSThe hemostatic abilities of the two methods were analyzed retrospectively in all six gastric endoscopic submucosal dissection cases. The treated vessel diameter, compressed vessel frequency, and bleeding frequency after cutting the vessels were noted by the recorded videos. The coagulation mechanism of the two power settings was evaluated using the data recording program and histological examination on macro- and microscopic levels in the ex vivo experiments using porcine tissues. RESULTSF1-10 method showed a significantly better hemostatic ability for vessels ≥ 2 mm in diameter and a trend of overall better coagulation effect, evaluated by the bleeding rate after cutting the vessels. F1-10 method could sustain electrical current longer and effectively coagulate the tissue wider and deeper than the S method in the porcine model. CONCLUSIONF1-10 method is suggested to achieve a stronger hemostatic effect than the S method in clinical procedures and ex vivo models.