AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT) scanning for detection of small hepatocellular carcinoma (HCC). METHODS: M...AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT) scanning for detection of small hepatocellular carcinoma (HCC). METHODS: MDCT scanning and baseline MRI with SE T1-WI and T2-WI sequence combined with FMPSPGR sequence were performed in 37 patients with 43 small HCCs. Receiver operating characteristic (ROC) curves were plotted to analyze the results for modality. RESULTS: The areas below ROC curve (Az) were calculated. There was no statistical difference in dynamic enhancement MDCT and MRI. The detection rate of small HCC was 97.5%-97.6% on multiphase MDCT scanning and 90.7%-94.7% on MRI, respectively. The sensitivity of detection for small HCC on MDCT scanning was higher than that on dynamic enhancement MRI. The sensitivity of detection for minute HCC (tumor diameter ≤ 1 cm) was 90.0%-95.0% on MDCT scanning and 70.0%-85.0% on MRI, respectively. CONCLUSION: MDCT scanning should be performed for early detection and effective treatment of small HCC in patients with chronic hepatitis and cirrhosis during follow-up.展开更多
The single fault and multiple fault detections for multiple-valued logic circuits are studied in this paper. Firstly, it is shown that the cardinality of optimal single fault test set for fanout-free m-valued circuits...The single fault and multiple fault detections for multiple-valued logic circuits are studied in this paper. Firstly, it is shown that the cardinality of optimal single fault test set for fanout-free m-valued circuits with n primary inputs is not more than n + 1, for linear tree circuits is two, and for multiplication modulo circuits is two if n is an odd number or if n is an even number and m > 3, where the optimal test set of a circuit has minimal number of test vectors. Secondly,it is indicated that the cardinality of optimal multiple fault test set for linear tree circuits with n primary inputs is 1 + [n/(m - 1)], for multiplication modulo circuits is n+ 1, for fanout-free circuits that consist of 2-input linear tree circuits and 2-input multiplication modulo circuits is not greater than n+ 1, where [x] denotes the smallest integer greater than or equal to x. Finally,the single fault location approaches of linear tree circuits and multiplication modulo circuits are presented, and all faults in the two types of circuits can be located by using a test set with n + 1 vectors.展开更多
基金a financial assistance from Zhuhai Technology Bureau, No. PC20052025
文摘AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT) scanning for detection of small hepatocellular carcinoma (HCC). METHODS: MDCT scanning and baseline MRI with SE T1-WI and T2-WI sequence combined with FMPSPGR sequence were performed in 37 patients with 43 small HCCs. Receiver operating characteristic (ROC) curves were plotted to analyze the results for modality. RESULTS: The areas below ROC curve (Az) were calculated. There was no statistical difference in dynamic enhancement MDCT and MRI. The detection rate of small HCC was 97.5%-97.6% on multiphase MDCT scanning and 90.7%-94.7% on MRI, respectively. The sensitivity of detection for small HCC on MDCT scanning was higher than that on dynamic enhancement MRI. The sensitivity of detection for minute HCC (tumor diameter ≤ 1 cm) was 90.0%-95.0% on MDCT scanning and 70.0%-85.0% on MRI, respectively. CONCLUSION: MDCT scanning should be performed for early detection and effective treatment of small HCC in patients with chronic hepatitis and cirrhosis during follow-up.
基金Supported by the National Natural Science Foundation of China (No.60006002) Education Department of Guangdong Province of China (No. Z02019)
文摘The single fault and multiple fault detections for multiple-valued logic circuits are studied in this paper. Firstly, it is shown that the cardinality of optimal single fault test set for fanout-free m-valued circuits with n primary inputs is not more than n + 1, for linear tree circuits is two, and for multiplication modulo circuits is two if n is an odd number or if n is an even number and m > 3, where the optimal test set of a circuit has minimal number of test vectors. Secondly,it is indicated that the cardinality of optimal multiple fault test set for linear tree circuits with n primary inputs is 1 + [n/(m - 1)], for multiplication modulo circuits is n+ 1, for fanout-free circuits that consist of 2-input linear tree circuits and 2-input multiplication modulo circuits is not greater than n+ 1, where [x] denotes the smallest integer greater than or equal to x. Finally,the single fault location approaches of linear tree circuits and multiplication modulo circuits are presented, and all faults in the two types of circuits can be located by using a test set with n + 1 vectors.