期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
浅谈建设工程“多测合一”的应用
1
作者 莫玛璐 《浙江测绘》 2020年第4期47-49,46,共4页
建设工程测绘涉及多项内容,传统测绘没有统一标准,重复测绘,严重浪费测绘资源,增加工程间接费用及时间成本,不利于建设市场资本投资及行政审批决策。为优化建设市场营商环境,推进政府“简政放权”,进一步深化“放管服”改革,各地推出“... 建设工程测绘涉及多项内容,传统测绘没有统一标准,重复测绘,严重浪费测绘资源,增加工程间接费用及时间成本,不利于建设市场资本投资及行政审批决策。为优化建设市场营商环境,推进政府“简政放权”,进一步深化“放管服”改革,各地推出“多测合一”模式,实行建设工程项目统一测绘、成果共享,节约建设成本,提高工作效率,提升政府服务水平。 展开更多
关键词 建设工程 规划 多测'一■
下载PDF
Mapping methods for output-based objective speech quality assessment using data mining 被引量:2
2
作者 王晶 赵胜辉 +1 位作者 谢湘 匡镜明 《Journal of Central South University》 SCIE EI CAS 2014年第5期1919-1926,共8页
Objective speech quality is difficult to be measured without the input reference speech.Mapping methods using data mining are investigated and designed to improve the output-based speech quality assessment algorithm.T... Objective speech quality is difficult to be measured without the input reference speech.Mapping methods using data mining are investigated and designed to improve the output-based speech quality assessment algorithm.The degraded speech is firstly separated into three classes(unvoiced,voiced and silence),and then the consistency measurement between the degraded speech signal and the pre-trained reference model for each class is calculated and mapped to an objective speech quality score using data mining.Fuzzy Gaussian mixture model(GMM)is used to generate the artificial reference model trained on perceptual linear predictive(PLP)features.The mean opinion score(MOS)mapping methods including multivariate non-linear regression(MNLR),fuzzy neural network(FNN)and support vector regression(SVR)are designed and compared with the standard ITU-T P.563 method.Experimental results show that the assessment methods with data mining perform better than ITU-T P.563.Moreover,FNN and SVR are more efficient than MNLR,and FNN performs best with 14.50% increase in the correlation coefficient and 32.76% decrease in the root-mean-square MOS error. 展开更多
关键词 objective speech quality data mining multivariate non-linear regression fuzzy neural network support vector regression
下载PDF
Simultaneous determination of five phenylethanoid glycosides in Cistanches Herba using quantitative analysis of multi-components by single marker 被引量:9
3
作者 Ruiyan Li Mingbo Zhao +1 位作者 Pengfei Tu Yong Jiang 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2019年第8期537-546,共10页
In the present study, a method for the quantitative analysis of multi-components by single marker(QAMS) has been developed and validated for the simultaneous determination of echinacoside(ECH), tubuloside A, acteoside... In the present study, a method for the quantitative analysis of multi-components by single marker(QAMS) has been developed and validated for the simultaneous determination of echinacoside(ECH), tubuloside A, acteoside, isoacteoside, and2’-acetylacteoside in Cistanches Herba. ECH was used as the internal standard(IS) to obtain the relative correction factors(RCFs) of the other four phenylethanoid glycosides(PhGs);meanwhile, various influencing factors on RCFs were investigated under different conditions. The content of each component was calculated with RCF. The results were compared with those obtained by the external standard method(ESM) to verify the feasibility and accuracy of the established QAMS method. No significant difference was found in the quantitative results of 10 batches of Cistanches Herba between QAMS and ESM. The proposed QAMS method for simultaneous determination of PhGs in Cistanches Herba is accurate and feasible, providing an efficient and economical approach for the quality control of Cistanches Herba. 展开更多
关键词 Cistanches Herba Phenylethanoid glycosides Quantitative analysis of multi-components by single-marker Relative correction factors
原文传递
Disposable paper-based bipolar electrode array for multiplexed electrochemiluminescence detection of pathogenic DNAs 被引量:2
4
作者 Qiumei Feng Hongyuan Chen Jingjuan Xu 《Science China Chemistry》 SCIE EI CAS CSCD 2015年第5期810-818,共9页
A novel disposable paper-based bipolar electrode (BPE) array is fabricated for multiplexed electrochemiluminescence (ECL) detection of pathogenic DNAs. This proposed BPE array device consists of 15 units, each con... A novel disposable paper-based bipolar electrode (BPE) array is fabricated for multiplexed electrochemiluminescence (ECL) detection of pathogenic DNAs. This proposed BPE array device consists of 15 units, each consisting of six sensing cells and two reporting cells patterned using hydrophobic wax. A hairpin structure DNA assembled on the cathodes of BPEs hybridizes with Pt nanoparticles (NPs) labeled probe DNA in the presence of complementary target DNA. The introduction of Pt NPs catalyzes the reduction of dissolved 02 at cathodes and induces an enhanced ECL signal from Ru(bpy)32+/tripropylamine (TPrA) at the anodes of BPEs. The dissolved 02 lost in reduction reaction could be promptly replenished due to the relatively large contact area of the paper-based cells with air, which ensures the stability of ECL signal. This obtained paper-based BPE array sensor showed excellent performances for the multiplexed analysis of the syphilis (Treponema pallidum) gene, the immunodeficiency virus gene (HIV) and hepatitis B virus gene (HBV). 展开更多
关键词 paper-based device bipolar electrode array pathogenic DNAs multiple detection ELECTROCHEMILUMINESCENCE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部