It is impossible to plan in advance unpredictable phenomena at monitoring, diagnosis and control of industrial batch and continuous equipment and processes such as chemical composition of the raw materials, the proces...It is impossible to plan in advance unpredictable phenomena at monitoring, diagnosis and control of industrial batch and continuous equipment and processes such as chemical composition of the raw materials, the process leads to unexpected reactions and changes its parameters, etc. The agent is active, a program entity, has its own ideas how to perform the tasks of the own agenda. Agents perceive, behave "reasonably", communicate with other agents. Agents can represent equipment and operations in batch processes as recommended by the ISA $88. Jadex system is based on Java language and on FIPA org. recommendations. The description of ripening tank T406 and recipe for yogurt production in the holding of MADETA Corp. in the Czech Rep. It is described modeling and displaying of"normal" and error, fault unit state of the ripening tank. Agents are within the Jadex system and describing the behavior of ripening tank T406 with state diagrams-automata and assist in diagnosing of fault states. States are described in XML language-SCXML (State Charts XML). Jadex Control Center-JCC represents a major access point to use for operating in real time.展开更多
In chronic stage of stroke, it is necessary to pay attention to the complex spatial movements training along with the traditional restoration of balance, strength of particular muscles, and paretic limb joints mobilit...In chronic stage of stroke, it is necessary to pay attention to the complex spatial movements training along with the traditional restoration of balance, strength of particular muscles, and paretic limb joints mobility. The aim of the study was to evaluate the effectiveness of robotic therapy in the recovery of upper limb function in the chronic stage of stroke. The study involved 52 patients with ischemic stroke in the middle cerebral artery. The patients were divided randomly into 2 groups. All patients (5 days/wk × 3 wk) got gymnastics by the standard technique, massage, laser, and pulsed currents therapy. Main group patients (n = 36) extra received complex spatial movements, speed, fluidity, precision and agility training by the robotic electromechanical device Multi Joint System (MJS) (40 minutes, 5 days/wk × 3 wk). Analysis of the results of the study showed a statistically significant difference in improving ROM of the elbow and shoulder joints, speed and accuracy of movement in the main group compared with the control. Hardware recovery of complex spatial upper limb movements in the chronic stage of stroke increases the functionality and independence of the patient's domestic skills.展开更多
文摘It is impossible to plan in advance unpredictable phenomena at monitoring, diagnosis and control of industrial batch and continuous equipment and processes such as chemical composition of the raw materials, the process leads to unexpected reactions and changes its parameters, etc. The agent is active, a program entity, has its own ideas how to perform the tasks of the own agenda. Agents perceive, behave "reasonably", communicate with other agents. Agents can represent equipment and operations in batch processes as recommended by the ISA $88. Jadex system is based on Java language and on FIPA org. recommendations. The description of ripening tank T406 and recipe for yogurt production in the holding of MADETA Corp. in the Czech Rep. It is described modeling and displaying of"normal" and error, fault unit state of the ripening tank. Agents are within the Jadex system and describing the behavior of ripening tank T406 with state diagrams-automata and assist in diagnosing of fault states. States are described in XML language-SCXML (State Charts XML). Jadex Control Center-JCC represents a major access point to use for operating in real time.
文摘In chronic stage of stroke, it is necessary to pay attention to the complex spatial movements training along with the traditional restoration of balance, strength of particular muscles, and paretic limb joints mobility. The aim of the study was to evaluate the effectiveness of robotic therapy in the recovery of upper limb function in the chronic stage of stroke. The study involved 52 patients with ischemic stroke in the middle cerebral artery. The patients were divided randomly into 2 groups. All patients (5 days/wk × 3 wk) got gymnastics by the standard technique, massage, laser, and pulsed currents therapy. Main group patients (n = 36) extra received complex spatial movements, speed, fluidity, precision and agility training by the robotic electromechanical device Multi Joint System (MJS) (40 minutes, 5 days/wk × 3 wk). Analysis of the results of the study showed a statistically significant difference in improving ROM of the elbow and shoulder joints, speed and accuracy of movement in the main group compared with the control. Hardware recovery of complex spatial upper limb movements in the chronic stage of stroke increases the functionality and independence of the patient's domestic skills.