The property of multi-band operation has been studied and investigated analytically through the design of a rectangular patch microstrip antenna having different numbers of wide slots arranged at both the radiating ed...The property of multi-band operation has been studied and investigated analytically through the design of a rectangular patch microstrip antenna having different numbers of wide slots arranged at both the radiating edges. The analyses were carried out using the method of moments simulation software. It is shown that a patch with three slots has a multi-band feature with four resonant frequencies at 1.6, 1.8, 2.65, and 4.83 GHz and adequate values of return loss and gain. It is also shown that a patch with two pairs of wide slots arranged at both the radiating edges has the dual band feature with resonant frequencies at 1.64 and 1.8 GHz and good values of return loss and gain.展开更多
Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique i...Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique is described and demonstrated by analyzing data from both simulated and real plant data of a chemical process plant. Results show that the proposed approach can map multiple oscillatory sources onto the most appropriate control loops,and has superior performance in terms of reconstruction accuracy and intuitive understanding compared with spectral independent component analysis(ICA).展开更多
In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator a...In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation.展开更多
文摘The property of multi-band operation has been studied and investigated analytically through the design of a rectangular patch microstrip antenna having different numbers of wide slots arranged at both the radiating edges. The analyses were carried out using the method of moments simulation software. It is shown that a patch with three slots has a multi-band feature with four resonant frequencies at 1.6, 1.8, 2.65, and 4.83 GHz and adequate values of return loss and gain. It is also shown that a patch with two pairs of wide slots arranged at both the radiating edges has the dual band feature with resonant frequencies at 1.64 and 1.8 GHz and good values of return loss and gain.
基金Supported by the Scientific Research Foundation for the Returned Overseas Chinese Scholars,State Education Ministry.
文摘Constrained spectral non-negative matrix factorization(NMF)analysis of perturbed oscillatory process control loop variable data is performed for the isolation of multiple plant-wide oscillatory sources.The technique is described and demonstrated by analyzing data from both simulated and real plant data of a chemical process plant. Results show that the proposed approach can map multiple oscillatory sources onto the most appropriate control loops,and has superior performance in terms of reconstruction accuracy and intuitive understanding compared with spectral independent component analysis(ICA).
文摘In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation.