The paper presents an experimental study on the heat transfer and flow friction characteristics in a solar air heater channel fitted with delta-winglet type vortex generators (DWs). The experiments are conducted by ...The paper presents an experimental study on the heat transfer and flow friction characteristics in a solar air heater channel fitted with delta-winglet type vortex generators (DWs). The experiments are conducted by varying the airflow rate for Reynolds number in the range of 5000 to 24000 in the test section with a uniform heat-flux applied on the upper channel wall. Firstly, the DW pairs are mounted only at the entrance of the lower wall of the test channel (called DW-E) to create multiple vortex flows at the entry. The effect of two transverse pitches (Re= Pt/H= 1 and 2) at three attack angles (a= 30°, 45° and 60°) of the DW-E with its relative height, b/H= 0.5 (half height of channel) is examined. Secondly, the 30° DWs with three different relative heights (blH = 0.3, 0.4 and 0.5) are placed on the upper wall only (absorber plate, called DW-A) of the test channel. The experimental result reveals that in the first case, the 60° DW-E at Rp = 1 provides the highest heat transfer and friction factor while the 30° DW-E at Rp = 1 performs overall better than the others. In the second case, the 30° DW-A at b/H= 0.5 yields the highest heat transfer and friction factor but the best thermal performance is found at b/H = 0.4.展开更多
An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and...An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45°. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within ± 2 ℃. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within ± 2 ℃. The heater performed better as inclination increased.展开更多
An experimental study was conducted on three models of solar collectors having an absorber made of concrete designed and built in the TPL (Thermal Process Laboratory). A sequence of tests was performed on these mode...An experimental study was conducted on three models of solar collectors having an absorber made of concrete designed and built in the TPL (Thermal Process Laboratory). A sequence of tests was performed on these models for the two air circulation models (forced and natural) in order to compare their thermal performance. The results are presented in terms of useful energy, stored energy and thermal efficiency of each model.展开更多
文摘The paper presents an experimental study on the heat transfer and flow friction characteristics in a solar air heater channel fitted with delta-winglet type vortex generators (DWs). The experiments are conducted by varying the airflow rate for Reynolds number in the range of 5000 to 24000 in the test section with a uniform heat-flux applied on the upper channel wall. Firstly, the DW pairs are mounted only at the entrance of the lower wall of the test channel (called DW-E) to create multiple vortex flows at the entry. The effect of two transverse pitches (Re= Pt/H= 1 and 2) at three attack angles (a= 30°, 45° and 60°) of the DW-E with its relative height, b/H= 0.5 (half height of channel) is examined. Secondly, the 30° DWs with three different relative heights (blH = 0.3, 0.4 and 0.5) are placed on the upper wall only (absorber plate, called DW-A) of the test channel. The experimental result reveals that in the first case, the 60° DW-E at Rp = 1 provides the highest heat transfer and friction factor while the 30° DW-E at Rp = 1 performs overall better than the others. In the second case, the 30° DW-A at b/H= 0.5 yields the highest heat transfer and friction factor but the best thermal performance is found at b/H = 0.4.
文摘An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45°. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within ± 2 ℃. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within ± 2 ℃. The heater performed better as inclination increased.
文摘An experimental study was conducted on three models of solar collectors having an absorber made of concrete designed and built in the TPL (Thermal Process Laboratory). A sequence of tests was performed on these models for the two air circulation models (forced and natural) in order to compare their thermal performance. The results are presented in terms of useful energy, stored energy and thermal efficiency of each model.