The transient plane source(TPS)method is developed recently to measure the thermal conductivity of materials.In the measurement,the heating power is influenced by the heat which is transferred via the probe electrical...The transient plane source(TPS)method is developed recently to measure the thermal conductivity of materials.In the measurement,the heating power is influenced by the heat which is transferred via the probe electrical leads.This fact further influences the measurement accuracy of thermal conductivity.To solve this problem,the influence of heat loss through the electrical leads on the heating power is studied theoretically.The mathematical formula of heat loss is deduced,and the corresponding correction model is presented.A series of measurement experiments on different materials have been conducted by using the hot disk thermal constant analyzer.The results show that the influence of the heat loss on the measurement is sensitive to different test materials and probes with different sizes.When the thermal conductivity of the material is greater than 0.2 W/(m·K),the influence of the heat loss is less than 0.16%,which can be ignored.As to the lower thermal conductivity materials,it is necessary to compensate the heat loss through the electrical leads,and the accuracy of thermal conductivity measurement can be effectively improved.展开更多
The paper presents an experimental investigation on enhanced heat transfer and pressure loss characteristics by using single, double, triple, and quadruple twisted-tape inserts in a round tube having a uniform heat-fl...The paper presents an experimental investigation on enhanced heat transfer and pressure loss characteristics by using single, double, triple, and quadruple twisted-tape inserts in a round tube having a uniform heat-fluxed wall. The investigation has been conducted in the heat exchanger tube inserted with various twisted-tape numbers for co- and counter-twist arrangements for the turbulent air flow, Reynolds number (Re) from 5300 to 24000. The typical single twisted-tape inserts at two twist ratios, y/w = 4 and 5, are used as the base case, while the other multiple twisted-tape inserts are aty/w = 4 only. The experimental results of heat transfer and pressure drop in terms of Nusselt number (Nu) and friction factor 00, respectively, reveal that Nu increases with the increment of Re and of twisted-tape number. The values of Nu for the inserted tube are in a range of 1.15-2.12 times that for the plain tube while f is 1.9-4.1 times. The thermal enhancement factor of the inserted tube under similar pumping power is evaluated and found to be above unity except for the single and the double co-twisted tapes. The quadruple counter-twisted tape insert provides the maximum thermal performance.展开更多
文摘The transient plane source(TPS)method is developed recently to measure the thermal conductivity of materials.In the measurement,the heating power is influenced by the heat which is transferred via the probe electrical leads.This fact further influences the measurement accuracy of thermal conductivity.To solve this problem,the influence of heat loss through the electrical leads on the heating power is studied theoretically.The mathematical formula of heat loss is deduced,and the corresponding correction model is presented.A series of measurement experiments on different materials have been conducted by using the hot disk thermal constant analyzer.The results show that the influence of the heat loss on the measurement is sensitive to different test materials and probes with different sizes.When the thermal conductivity of the material is greater than 0.2 W/(m·K),the influence of the heat loss is less than 0.16%,which can be ignored.As to the lower thermal conductivity materials,it is necessary to compensate the heat loss through the electrical leads,and the accuracy of thermal conductivity measurement can be effectively improved.
基金the Thailand Research Fund(TRF)(Grant No.Ph D/0143/2552)
文摘The paper presents an experimental investigation on enhanced heat transfer and pressure loss characteristics by using single, double, triple, and quadruple twisted-tape inserts in a round tube having a uniform heat-fluxed wall. The investigation has been conducted in the heat exchanger tube inserted with various twisted-tape numbers for co- and counter-twist arrangements for the turbulent air flow, Reynolds number (Re) from 5300 to 24000. The typical single twisted-tape inserts at two twist ratios, y/w = 4 and 5, are used as the base case, while the other multiple twisted-tape inserts are aty/w = 4 only. The experimental results of heat transfer and pressure drop in terms of Nusselt number (Nu) and friction factor 00, respectively, reveal that Nu increases with the increment of Re and of twisted-tape number. The values of Nu for the inserted tube are in a range of 1.15-2.12 times that for the plain tube while f is 1.9-4.1 times. The thermal enhancement factor of the inserted tube under similar pumping power is evaluated and found to be above unity except for the single and the double co-twisted tapes. The quadruple counter-twisted tape insert provides the maximum thermal performance.