Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base...Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.展开更多
Objective: To study the pharmacokinetics of native r SAK in rabbit's femoral artery thrombosis model, the “lytic circle' method was used to determine plasma levels of r SAK. Methods: Thirty New Zealand rabb...Objective: To study the pharmacokinetics of native r SAK in rabbit's femoral artery thrombosis model, the “lytic circle' method was used to determine plasma levels of r SAK. Methods: Thirty New Zealand rabbits were randomly assigned to the control (saline 10 ml, 30 min), r SAK low dose (0.25 mg/kg, 30 min), medial dose (0.50 mg/kg, 30 min), high dose (1.00 mg/kg, 30 min), single bolus (0.50 mg/kg, 2 min) and conjunctive therapy (initiated with heparin 200 U/kg, followed by infusion of r SAK 0.50 mg/kg for 30 min, and subsequently infused heparin 50 U/(kg·h) to endpoint) groups. The right femoral artery thrombosis model in rabbit was made by balloon injury, then the thrombolytic agents were infused through parallel ear vein and the blood samples were collected pre thrombolysis and at different time post thrombolysis to determine the plasma levels of r SAK by “lytic circle' method, the plasma levels of r SAK were processed by pharmacokinetic computing procedure to fit the model. Results: The plasma levels of r SAK and the diameters of lytic circles showed a pretty good linear correlation under the scope of 2.0×10 4 2.0×10 6 U/L, and the averaged recycle rate was (96.05±11.35)%(RSD =±11.82%).All peak concentration time in each infusion group was 30 min, and the peak concentrations positively correlated with the doses administrated in infusion groups(r=0.999 98, P <0.000 1). In single bolus group, Peak concentration time was 2 min, and the peak concentration reached (5.16±1.02) mg/L, which was significant higher than that in the same dose r SAK infusion group ( P <0.01). In conjunctive therapy group, the peak concentration showed no significant difference from that in the same dose r SAK infusion group ( P >0.05). The plasma levels of r SAK fit in two compartment model as processed by pharmacokinetic computing procedure in each group. Conclusion: The “lytic circle' method is a simple, practical and reliable method to determine the plasma level of r SAK, and the pharmacokinetics of native r SAK infusion fits in two compartment model in rabbit's femoral artery thrombosis model.展开更多
Aim To prepare a self-emulsifying microemulsion of 9-nitrocamptothecin (9-NC ME) for intravenous injection and investi- gation of its pharmacokinetic profiles in normal SD rats. Methods 9-NC ME was optimized in term...Aim To prepare a self-emulsifying microemulsion of 9-nitrocamptothecin (9-NC ME) for intravenous injection and investi- gation of its pharmacokinetic profiles in normal SD rats. Methods 9-NC ME was optimized in terms of droplet size and lack of drug precipitation following aqueous dilution using a pseudo-ternary phase diagram. Physicochemical properties of 9-NC ME were evaluated. 9-NC ME was intravenously administered via tail vein in healthy rats. Results A stable microemulsion was formulated consisted of soybean oil as oil phase, EPC/Tween-80 as emulsifier, and anhydrous ethanol as co-emulsifier. The droplets of the microemulsion were spherical shape with mean diameter of 38.3 ± 4.0 nm after 1:20 dilution with 5% glucose injection. The pharmacokinetic parameters of 9-NC ME after intravenous administration in rats were t1/2 of 0.97 ± 0.14 h, A UC0-8 of 372.77 ±49.62 ng·h·mL^-1 and MRT of 1.40 ± 0.21 h which were 1.4-fold, 1.65-fold, and 1.4-fold more than those of 9-NC solution (P〈0.01). Conclusion The results suggested that 9-NC ME was a promising drug delivery system and it was expected to provide a novel 9-NC injection for cancer patients.展开更多
The effects of current pulsing on the microstructure, hardness and tensile properties at different temperatures of gas tungsten arc (GTA) weldments of titanium matrix composites were studied. Full-penetration butt j...The effects of current pulsing on the microstructure, hardness and tensile properties at different temperatures of gas tungsten arc (GTA) weldments of titanium matrix composites were studied. Full-penetration butt joints were made with or without current pulsing. Optical microscopy, hardness test and scanning electron microscopy were employed to evaluate the metallurgical characteristics of welded joints. Tensile properties of weldments at different temperatures were studied and correlated with the microstructure. The results exhibit that current pulsing leads to the refinement of the weld microstrucmre and TiB whisker and the redistribution of reinforcements resulting in higher hardness, tensile strength and ductility of weldments in the as-welded condition.展开更多
The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw...The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.展开更多
AIM: To identify the criteria for the differentiation of hilar cholangiocarcinoma (HCCA) from benign strictures. METHODS: A total of 68 patients underwent resection of lesions suspicious for HCCA between 1998 and 2006...AIM: To identify the criteria for the differentiation of hilar cholangiocarcinoma (HCCA) from benign strictures. METHODS: A total of 68 patients underwent resection of lesions suspicious for HCCA between 1998 and 2006. The results of laboratory investigations, imaging studies and brush cytology were collected. These fi ndings were analyzed to obtain the fi nal diagnosis. RESULTS: Histological examination of the resected specimens confirmed HCCA in 58 patients (85%, group Ⅰ) whereas 10 patients (15%, groupⅡ) were diagnosed to have benign strictures. The most common presenting symptom was obstructive jaundice in 77% patients (79% group Ⅰvs 60% group Ⅱ P = 0.23). Laboratory findings showed greater elevation of transaminase levels in group Ⅰcompared to group Ⅱ The various imaging modalities showed vascular involvement exclusively in the malignant group (36%,P < 0.05). Brush cytology was positive for malignant cells in only 50% patients in group Ⅰ whereas none in group Ⅱ showed malignant cells. CONCLUSION: Despite improvements in imaging techniques, 10 patients (15%) with a presumptive diagnosis of HCCA were ultimately found to have benign strictures. Except for vascular involvement which was associated significantly with malignancy, there were no conclusive features of malignancy on regular imaging modalities. This uncertainty should be taken into account when patients with a suspicious lesion at the liver hilum are considered for resection.展开更多
This paper proposes a kind of least square modeling method based on typical signal response to enhance modeling accuracy of heat engineering process and adapts the environment that modeling experiment conditions are l...This paper proposes a kind of least square modeling method based on typical signal response to enhance modeling accuracy of heat engineering process and adapts the environment that modeling experiment conditions are limited. The principle of this method is, under the condition of known typical pulse, step and slope signal response and model structure, to give algorithm of model parameters of identified continuous system by least square mode through derivation. The method is applied to the identification of heat exchange process for a consumer substation, and identification result obtained is compared with that of other conventional methods. After the comparison the result shows that identification accuracy is improved obviously. In addition to the good identification accuracy, this method has the characteristics such as it can identify directly continuous system model, pure lagging time, and is not sensitive to data length in the identification process. All these characteristics show that this method is simple, easy to implement and has good practicability.展开更多
AIM: To prospectively assess the changes in parameters of computed tomography (CT) perfusion pre- and post-transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) in different treatment respons...AIM: To prospectively assess the changes in parameters of computed tomography (CT) perfusion pre- and post-transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) in different treatment response groups, and to correlate the changes with various responses of HCC to TACE. METHODS: Thirty-nine HCC patients underwent CT perfusion examinations pre-(1 d before TACE) and post-treatment (4 wk after TACE). The response evaluation criteria for solid tumors (RECIST) were referred to when treatment responses were distributed. Wilcoxon-signed ranks test was used to compare the differences in CT perfusion parameters pre- and post- TACE for different response groups. RESULTS: Only one case had treatment response to CR and the CT perfusion maps of post-treatment lesion displayed complete absence of signals. In the PR treatment response group, hepatic artery perfusion (HAP), hepatic arterial fracture (HAF) and hepatic blood volume (HBV) of viable tumors post-TACE were reduced compared with pre-TACE (P = 0.001, 0.030 and 0.001, respectively). In the SD group, all CT perfusion parameters were not significantly different pre- and post-TACE. In the PD group, HAP, HAl=, portal vein perfusion (PVP) and hepatic blood flow (HBF) of viable tumors post-TACE were significantly increased compared with pre-TACE (P = 0.005, 0.012, 0.035 and 0.005, respectively). CONCLUSION: Changes in CT perfusion parameters of viable tumors are correlated with different responses of HCC to TACE. Therefore, CT perfusion imaging is a feasible technique for monitoring response of HCC to TACE.展开更多
Batch experiments tively evaluate the inhibition were conducted to compara- effects and mechanisms of a low-concentration (1%) proline solution cover on the release of pollutants from high-sulfur coal gangue. High- ...Batch experiments tively evaluate the inhibition were conducted to compara- effects and mechanisms of a low-concentration (1%) proline solution cover on the release of pollutants from high-sulfur coal gangue. High- sulfur coal gangue was continuously immersed in a proline solution and in deionized water (as a control treatment) for 540 days. The results showed that the coal gangue in the control treatment was oxidized and generated leachate with poor water qualities, i.e., the leachate exhibited lower pH values, higher redox potential values, higher pollutant concentrations (804^2-, Fe, Mn, Cu, and Zn), and high levels of acidophilic sulfur-oxidizing bacteria. However, compared to the control treatment, the addition of the proline solution (1%) significantly improved the water quality of the leachate by significantly reducing the Eh values, the pollutant concentrations (804^2-, Fe^2+, Fe, Mn, Cu, and Zn), and the activity of acidophilic sulfur-oxidiz- ing bacteria and by significantly increasing the pH value to neutral. The proline treatment significantly inhibited the oxidation of coal gangue and the release of pollutants, mainly by inhibiting the activity of acidophilic sulfur-ox- idizing bacteria and by altering the heavy metal fractions and the mineralogical characteristics. Therefore, in engi- neering practice, workers should consider using an envi- ronmental friendly aqueous proline solution cover to achieve the in-situ control of pollutant releases from coal gangue dumps.展开更多
A novel and simple method to generate low timing jitter and discrete tunable dual-wavelength optical pulses at arbitrary repetition rates is demonstrated in this paper.Two multiple quantum wells distributed feedback l...A novel and simple method to generate low timing jitter and discrete tunable dual-wavelength optical pulses at arbitrary repetition rates is demonstrated in this paper.Two multiple quantum wells distributed feedback laser diodes,were used as the external seeding sources to inject the external photons into a gain-switched Fabry-Perot laser diode.The output wavelengths can be tuned discretely to coincide with any two lasing modes in the gain spectra range of the Fabry-Perot Laser diode,and the output side mode suppression ratio was better than 25 dB.Moreover,the timing jitter of optical pulses was reduced from 1.89 ps to 0.83 ps.It was empirically found that the lowest timing jitter operation occurred when the injected light wavelength is 0.2-0.3 nm shorter than the locked mode of the Fabry-Perot laser diode.To our knowledge,this is the first report of using two DFB laser diodes as a seeding source to reduce pulses jitter and select lasing dual-wavelength simultaneously.展开更多
文摘Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
文摘Objective: To study the pharmacokinetics of native r SAK in rabbit's femoral artery thrombosis model, the “lytic circle' method was used to determine plasma levels of r SAK. Methods: Thirty New Zealand rabbits were randomly assigned to the control (saline 10 ml, 30 min), r SAK low dose (0.25 mg/kg, 30 min), medial dose (0.50 mg/kg, 30 min), high dose (1.00 mg/kg, 30 min), single bolus (0.50 mg/kg, 2 min) and conjunctive therapy (initiated with heparin 200 U/kg, followed by infusion of r SAK 0.50 mg/kg for 30 min, and subsequently infused heparin 50 U/(kg·h) to endpoint) groups. The right femoral artery thrombosis model in rabbit was made by balloon injury, then the thrombolytic agents were infused through parallel ear vein and the blood samples were collected pre thrombolysis and at different time post thrombolysis to determine the plasma levels of r SAK by “lytic circle' method, the plasma levels of r SAK were processed by pharmacokinetic computing procedure to fit the model. Results: The plasma levels of r SAK and the diameters of lytic circles showed a pretty good linear correlation under the scope of 2.0×10 4 2.0×10 6 U/L, and the averaged recycle rate was (96.05±11.35)%(RSD =±11.82%).All peak concentration time in each infusion group was 30 min, and the peak concentrations positively correlated with the doses administrated in infusion groups(r=0.999 98, P <0.000 1). In single bolus group, Peak concentration time was 2 min, and the peak concentration reached (5.16±1.02) mg/L, which was significant higher than that in the same dose r SAK infusion group ( P <0.01). In conjunctive therapy group, the peak concentration showed no significant difference from that in the same dose r SAK infusion group ( P >0.05). The plasma levels of r SAK fit in two compartment model as processed by pharmacokinetic computing procedure in each group. Conclusion: The “lytic circle' method is a simple, practical and reliable method to determine the plasma level of r SAK, and the pharmacokinetics of native r SAK infusion fits in two compartment model in rabbit's femoral artery thrombosis model.
基金National Natural Science Foundation of China (GrantNo.30430760)the 985 projects (Phase II) of the State Key Labo-ratory of Natural and Biomimetic Drugs (Peking University, China).
文摘Aim To prepare a self-emulsifying microemulsion of 9-nitrocamptothecin (9-NC ME) for intravenous injection and investi- gation of its pharmacokinetic profiles in normal SD rats. Methods 9-NC ME was optimized in terms of droplet size and lack of drug precipitation following aqueous dilution using a pseudo-ternary phase diagram. Physicochemical properties of 9-NC ME were evaluated. 9-NC ME was intravenously administered via tail vein in healthy rats. Results A stable microemulsion was formulated consisted of soybean oil as oil phase, EPC/Tween-80 as emulsifier, and anhydrous ethanol as co-emulsifier. The droplets of the microemulsion were spherical shape with mean diameter of 38.3 ± 4.0 nm after 1:20 dilution with 5% glucose injection. The pharmacokinetic parameters of 9-NC ME after intravenous administration in rats were t1/2 of 0.97 ± 0.14 h, A UC0-8 of 372.77 ±49.62 ng·h·mL^-1 and MRT of 1.40 ± 0.21 h which were 1.4-fold, 1.65-fold, and 1.4-fold more than those of 9-NC solution (P〈0.01). Conclusion The results suggested that 9-NC ME was a promising drug delivery system and it was expected to provide a novel 9-NC injection for cancer patients.
基金Project(51371114)supported by the National Natural Science Foundation of ChinaProject(2012CB619600)supported by the National Basic Research Program of China+1 种基金Project(10SG15)supported by the Dawn Program of Shanghai Education Commission,ChinaProject(12XD1402800)supported by Shanghai Science and Technology Committee,China
文摘The effects of current pulsing on the microstructure, hardness and tensile properties at different temperatures of gas tungsten arc (GTA) weldments of titanium matrix composites were studied. Full-penetration butt joints were made with or without current pulsing. Optical microscopy, hardness test and scanning electron microscopy were employed to evaluate the metallurgical characteristics of welded joints. Tensile properties of weldments at different temperatures were studied and correlated with the microstructure. The results exhibit that current pulsing leads to the refinement of the weld microstrucmre and TiB whisker and the redistribution of reinforcements resulting in higher hardness, tensile strength and ductility of weldments in the as-welded condition.
基金Project (No. 50477033) supported by the National Natural Science Foundation of China
文摘The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.
文摘AIM: To identify the criteria for the differentiation of hilar cholangiocarcinoma (HCCA) from benign strictures. METHODS: A total of 68 patients underwent resection of lesions suspicious for HCCA between 1998 and 2006. The results of laboratory investigations, imaging studies and brush cytology were collected. These fi ndings were analyzed to obtain the fi nal diagnosis. RESULTS: Histological examination of the resected specimens confirmed HCCA in 58 patients (85%, group Ⅰ) whereas 10 patients (15%, groupⅡ) were diagnosed to have benign strictures. The most common presenting symptom was obstructive jaundice in 77% patients (79% group Ⅰvs 60% group Ⅱ P = 0.23). Laboratory findings showed greater elevation of transaminase levels in group Ⅰcompared to group Ⅱ The various imaging modalities showed vascular involvement exclusively in the malignant group (36%,P < 0.05). Brush cytology was positive for malignant cells in only 50% patients in group Ⅰ whereas none in group Ⅱ showed malignant cells. CONCLUSION: Despite improvements in imaging techniques, 10 patients (15%) with a presumptive diagnosis of HCCA were ultimately found to have benign strictures. Except for vascular involvement which was associated significantly with malignancy, there were no conclusive features of malignancy on regular imaging modalities. This uncertainty should be taken into account when patients with a suspicious lesion at the liver hilum are considered for resection.
基金Sponsored by the National Eleventh Five-year Plan Key Project of Ministry of Science and Technology of China(Grant No.2006BAJ03A05)and SpecialFunds for Research of Scientific and Technological Innovation Talents in Harbin(Grant No.RC2006XK007001).
文摘This paper proposes a kind of least square modeling method based on typical signal response to enhance modeling accuracy of heat engineering process and adapts the environment that modeling experiment conditions are limited. The principle of this method is, under the condition of known typical pulse, step and slope signal response and model structure, to give algorithm of model parameters of identified continuous system by least square mode through derivation. The method is applied to the identification of heat exchange process for a consumer substation, and identification result obtained is compared with that of other conventional methods. After the comparison the result shows that identification accuracy is improved obviously. In addition to the good identification accuracy, this method has the characteristics such as it can identify directly continuous system model, pure lagging time, and is not sensitive to data length in the identification process. All these characteristics show that this method is simple, easy to implement and has good practicability.
基金The Science Technology Program of Beijing Education Committee: KM200810025002
文摘AIM: To prospectively assess the changes in parameters of computed tomography (CT) perfusion pre- and post-transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) in different treatment response groups, and to correlate the changes with various responses of HCC to TACE. METHODS: Thirty-nine HCC patients underwent CT perfusion examinations pre-(1 d before TACE) and post-treatment (4 wk after TACE). The response evaluation criteria for solid tumors (RECIST) were referred to when treatment responses were distributed. Wilcoxon-signed ranks test was used to compare the differences in CT perfusion parameters pre- and post- TACE for different response groups. RESULTS: Only one case had treatment response to CR and the CT perfusion maps of post-treatment lesion displayed complete absence of signals. In the PR treatment response group, hepatic artery perfusion (HAP), hepatic arterial fracture (HAF) and hepatic blood volume (HBV) of viable tumors post-TACE were reduced compared with pre-TACE (P = 0.001, 0.030 and 0.001, respectively). In the SD group, all CT perfusion parameters were not significantly different pre- and post-TACE. In the PD group, HAP, HAl=, portal vein perfusion (PVP) and hepatic blood flow (HBF) of viable tumors post-TACE were significantly increased compared with pre-TACE (P = 0.005, 0.012, 0.035 and 0.005, respectively). CONCLUSION: Changes in CT perfusion parameters of viable tumors are correlated with different responses of HCC to TACE. Therefore, CT perfusion imaging is a feasible technique for monitoring response of HCC to TACE.
基金funded by a grant from the United Fund of Guizhou Province GovernmentNational Natural Science Foundation of China(No.U1612442-3)the Project of the Education Department of Guizhou Province(Nos.KY 2016011,GZZ201607,and ZDXK201611)
文摘Batch experiments tively evaluate the inhibition were conducted to compara- effects and mechanisms of a low-concentration (1%) proline solution cover on the release of pollutants from high-sulfur coal gangue. High- sulfur coal gangue was continuously immersed in a proline solution and in deionized water (as a control treatment) for 540 days. The results showed that the coal gangue in the control treatment was oxidized and generated leachate with poor water qualities, i.e., the leachate exhibited lower pH values, higher redox potential values, higher pollutant concentrations (804^2-, Fe, Mn, Cu, and Zn), and high levels of acidophilic sulfur-oxidizing bacteria. However, compared to the control treatment, the addition of the proline solution (1%) significantly improved the water quality of the leachate by significantly reducing the Eh values, the pollutant concentrations (804^2-, Fe^2+, Fe, Mn, Cu, and Zn), and the activity of acidophilic sulfur-oxidiz- ing bacteria and by significantly increasing the pH value to neutral. The proline treatment significantly inhibited the oxidation of coal gangue and the release of pollutants, mainly by inhibiting the activity of acidophilic sulfur-ox- idizing bacteria and by altering the heavy metal fractions and the mineralogical characteristics. Therefore, in engi- neering practice, workers should consider using an envi- ronmental friendly aqueous proline solution cover to achieve the in-situ control of pollutant releases from coal gangue dumps.
文摘A novel and simple method to generate low timing jitter and discrete tunable dual-wavelength optical pulses at arbitrary repetition rates is demonstrated in this paper.Two multiple quantum wells distributed feedback laser diodes,were used as the external seeding sources to inject the external photons into a gain-switched Fabry-Perot laser diode.The output wavelengths can be tuned discretely to coincide with any two lasing modes in the gain spectra range of the Fabry-Perot Laser diode,and the output side mode suppression ratio was better than 25 dB.Moreover,the timing jitter of optical pulses was reduced from 1.89 ps to 0.83 ps.It was empirically found that the lowest timing jitter operation occurred when the injected light wavelength is 0.2-0.3 nm shorter than the locked mode of the Fabry-Perot laser diode.To our knowledge,this is the first report of using two DFB laser diodes as a seeding source to reduce pulses jitter and select lasing dual-wavelength simultaneously.