The air permeability of airbag fabrics was measured at high pressure differential up to 200 kPa. It was found that permeability varied with pressure differential nonlinearly. The relationship between air permeability ...The air permeability of airbag fabrics was measured at high pressure differential up to 200 kPa. It was found that permeability varied with pressure differential nonlinearly. The relationship between air permeability and the pressure differential was fitted well with power law curve. The study revealed that the coefficient c and exponent b in the power law equation had a strong correlation with porosity, which was chosen to characterize the airbag fabrics.展开更多
Experimental investigations were conducted on the process of combustion and explosion vent in a 200 mm (diame- ter)×400 mm (length) vertical cylindrical vessel. When CH4-air mixture gases were used and the vent d...Experimental investigations were conducted on the process of combustion and explosion vent in a 200 mm (diame- ter)×400 mm (length) vertical cylindrical vessel. When CH4-air mixture gases were used and the vent diameter was 55 mm, conditions of Φ (equivalent ratio)=0.8, Φ=1.0 and Φ=1.3 and two ignition positions (at the cylinder center and bottom) were selected. The venting processes and the correlated factors are discussed in this paper.展开更多
The KHNP (Korea Hydro & Nuclear Power Co.) has developed a multipurpose nuclear safety analysis code called SPACE (the safety and performance analysis code) for nuclear power plants. SPACE code is a best-estimate...The KHNP (Korea Hydro & Nuclear Power Co.) has developed a multipurpose nuclear safety analysis code called SPACE (the safety and performance analysis code) for nuclear power plants. SPACE code is a best-estimated two-phase three-field thermal-hydraulic analysis code used to analyze the safety and performance of pressurized water reactors. In this paper, LOFT (loss of fluid test) L9-3 experiment using the SPACE code was selected to confirm the capability of SPACE code and the results calculated by the SPACE code are compared with those measured through the experiment. The results were compared with the experimental data and those of the other code simulations. Throughout the simulation result, it was concluded that the SPACE code can effectively simulate LOFT L9-3 experiment.展开更多
The original internal flooding probabilistic safety analysis (PSA) study of Krsko Nuclear Power Plant (two-loop Pressurized Water Reactor (PWR) plant of Westinghouse design) was performed in mid nineties and lim...The original internal flooding probabilistic safety analysis (PSA) study of Krsko Nuclear Power Plant (two-loop Pressurized Water Reactor (PWR) plant of Westinghouse design) was performed in mid nineties and limited to reactor core damage risk (Level 1 PSA). In 2003, it was, together with other safety and hazard analyses, subject to the Periodic Safety Review (PSR). In the PSR, it was stated that methodological PSA approaches and guidelines have evoluted during the past decade and several observations were provided, concerning the area screening process, residual risk and treatment of plant damage states and risk from radioactivity releases (i.e., Level 2 PSA). In order to address the PSR observations, upgrade ofKrsko NPP internal flooding PSA was undertaken. The area screening process was revisited in order to cover the areas without automatic reactor trip equipment. The model was extended to Level 2. Residual risk was estimated at both Level 1 and Level 2, in terms of core damage frequency (CDF) and large early release frequency (LERF), respectively.展开更多
With the promotion of agricultural ecological civilization construction in China, agricultural ecological security has received increasing attention. How to ensure agricultural ecological security has become a great c...With the promotion of agricultural ecological civilization construction in China, agricultural ecological security has received increasing attention. How to ensure agricultural ecological security has become a great concern for many scholars. As an important agricultural province in China, Hubei is of great significance to Chinese food security and agricultural sustainable development. This paper aims to establish an index system of agricultural ecological security and security classification of Hubei via Analytic Hierarchy Process and Pressure-State-Response methods. An evaluation of agricultural ecological security in Hubei, with a base of the national average value in 2015, reveals that the security degree has increased by 0.07566 from 0.90150 in 2005 to 0.97716 in 2015. Results show that agricultural ecological security in Hubei has improved but failed to reach the national average and there is still large space for improvement of the security level, considering a trend of deterioration in some indexes, such as per capita water resources, population density, per unit area pesticide load of farmland, forest coverage, grassland degradation rate and average annual precipitation. Influencing factors, especially population spatial distribution, misconduct in agricultural production, insufficient ability in agricultural natural disaster prevention, deficiency of agro-ecological technology of agricultural ecological security in Hubei are analyzed. For improvement of the degree of agricultural ecological security in Hubei, some countermeasures and suggestions are discussed.展开更多
基金This work was supported by the Excellence Young Teachers Program of Ministry of Education,P.R.C
文摘The air permeability of airbag fabrics was measured at high pressure differential up to 200 kPa. It was found that permeability varied with pressure differential nonlinearly. The relationship between air permeability and the pressure differential was fitted well with power law curve. The study revealed that the coefficient c and exponent b in the power law equation had a strong correlation with porosity, which was chosen to characterize the airbag fabrics.
基金Project (No. 19832030) supported by the National Natural Science Foundation of China
文摘Experimental investigations were conducted on the process of combustion and explosion vent in a 200 mm (diame- ter)×400 mm (length) vertical cylindrical vessel. When CH4-air mixture gases were used and the vent diameter was 55 mm, conditions of Φ (equivalent ratio)=0.8, Φ=1.0 and Φ=1.3 and two ignition positions (at the cylinder center and bottom) were selected. The venting processes and the correlated factors are discussed in this paper.
文摘The KHNP (Korea Hydro & Nuclear Power Co.) has developed a multipurpose nuclear safety analysis code called SPACE (the safety and performance analysis code) for nuclear power plants. SPACE code is a best-estimated two-phase three-field thermal-hydraulic analysis code used to analyze the safety and performance of pressurized water reactors. In this paper, LOFT (loss of fluid test) L9-3 experiment using the SPACE code was selected to confirm the capability of SPACE code and the results calculated by the SPACE code are compared with those measured through the experiment. The results were compared with the experimental data and those of the other code simulations. Throughout the simulation result, it was concluded that the SPACE code can effectively simulate LOFT L9-3 experiment.
文摘The original internal flooding probabilistic safety analysis (PSA) study of Krsko Nuclear Power Plant (two-loop Pressurized Water Reactor (PWR) plant of Westinghouse design) was performed in mid nineties and limited to reactor core damage risk (Level 1 PSA). In 2003, it was, together with other safety and hazard analyses, subject to the Periodic Safety Review (PSR). In the PSR, it was stated that methodological PSA approaches and guidelines have evoluted during the past decade and several observations were provided, concerning the area screening process, residual risk and treatment of plant damage states and risk from radioactivity releases (i.e., Level 2 PSA). In order to address the PSR observations, upgrade ofKrsko NPP internal flooding PSA was undertaken. The area screening process was revisited in order to cover the areas without automatic reactor trip equipment. The model was extended to Level 2. Residual risk was estimated at both Level 1 and Level 2, in terms of core damage frequency (CDF) and large early release frequency (LERF), respectively.
基金Key Project of National Social Science Fund of China(15AZD062)Graduate Education Innovation Program Fund of Zhongnan University of Economics and Law(2016Y1054)
文摘With the promotion of agricultural ecological civilization construction in China, agricultural ecological security has received increasing attention. How to ensure agricultural ecological security has become a great concern for many scholars. As an important agricultural province in China, Hubei is of great significance to Chinese food security and agricultural sustainable development. This paper aims to establish an index system of agricultural ecological security and security classification of Hubei via Analytic Hierarchy Process and Pressure-State-Response methods. An evaluation of agricultural ecological security in Hubei, with a base of the national average value in 2015, reveals that the security degree has increased by 0.07566 from 0.90150 in 2005 to 0.97716 in 2015. Results show that agricultural ecological security in Hubei has improved but failed to reach the national average and there is still large space for improvement of the security level, considering a trend of deterioration in some indexes, such as per capita water resources, population density, per unit area pesticide load of farmland, forest coverage, grassland degradation rate and average annual precipitation. Influencing factors, especially population spatial distribution, misconduct in agricultural production, insufficient ability in agricultural natural disaster prevention, deficiency of agro-ecological technology of agricultural ecological security in Hubei are analyzed. For improvement of the degree of agricultural ecological security in Hubei, some countermeasures and suggestions are discussed.