As a seed transmitted pathogen, pea seed_borne mosaic virus (PSbMV) not only replicates in embryonic cells but can also withstand seed desiccation. To understand the mechanism of PSbMV tolerance to seed desiccation, ...As a seed transmitted pathogen, pea seed_borne mosaic virus (PSbMV) not only replicates in embryonic cells but can also withstand seed desiccation. To understand the mechanism of PSbMV tolerance to seed desiccation, the authors compared the stability of viral coat protein (CP) and the distribution of viral particles in the cotyledon cells of pea (Pisum sativum L.) embryos collected before and after the dehydration process. Before dehydration, when the embryo was fresh and immature, degradation of CP was observed and a predominantly perinuclear distribution of viral particles in the cotyledon cells was evident. After dehydration, when the embryo was dry and mature, degradation of CP did not occur and the perinuclear viral distribution disappeared. Instead, aggregates containing PSbMV CP were found in the cytoplasm. Electron microscopy showed that these aggregates were composed of PSbMV particles. The formation of PSbMV particle aggregates is apparently triggered by seed dehydration and may be favorable to the virus survival in the desiccated embryonic cells.展开更多
Blood pumps have been adopted to treat heart failure over the past decades. A novel blood pump adopting the rotor with splitter blades and tandem cascade stator was developed recently. A particle image velocimetry (...Blood pumps have been adopted to treat heart failure over the past decades. A novel blood pump adopting the rotor with splitter blades and tandem cascade stator was developed recently. A particle image velocimetry (P1V) experiment was carried out to verify the design of the blood pump based on computational fluid dynamics (CFD) and further analyze the flow properties in the rotor and stator. The original sized pump model with an acrylic housing and an experiment loop were constructed to perform the optical measurement. The PIV testing was carried out at the rotational speed of 6952±50 r/rain with the flow rate of 3.1 l/rain and at 8186±50 r/min with 3.5 l/rain, respectively. The velocity and the Reynolds shear stress distributions were investigated by PIV and CFD, and the comparisons between them will be helpful for the future blood pump design.展开更多
文摘As a seed transmitted pathogen, pea seed_borne mosaic virus (PSbMV) not only replicates in embryonic cells but can also withstand seed desiccation. To understand the mechanism of PSbMV tolerance to seed desiccation, the authors compared the stability of viral coat protein (CP) and the distribution of viral particles in the cotyledon cells of pea (Pisum sativum L.) embryos collected before and after the dehydration process. Before dehydration, when the embryo was fresh and immature, degradation of CP was observed and a predominantly perinuclear distribution of viral particles in the cotyledon cells was evident. After dehydration, when the embryo was dry and mature, degradation of CP did not occur and the perinuclear viral distribution disappeared. Instead, aggregates containing PSbMV CP were found in the cytoplasm. Electron microscopy showed that these aggregates were composed of PSbMV particles. The formation of PSbMV particle aggregates is apparently triggered by seed dehydration and may be favorable to the virus survival in the desiccated embryonic cells.
基金supported by the National Natural Science Foundation of China (Grant Nos.50676004 and 50736007)the Science Foundation of Fuwai hospital (Grant No:2009F-010)the Key Subject Foundation of Beijing:Fluid Machinery and Engineering
文摘Blood pumps have been adopted to treat heart failure over the past decades. A novel blood pump adopting the rotor with splitter blades and tandem cascade stator was developed recently. A particle image velocimetry (P1V) experiment was carried out to verify the design of the blood pump based on computational fluid dynamics (CFD) and further analyze the flow properties in the rotor and stator. The original sized pump model with an acrylic housing and an experiment loop were constructed to perform the optical measurement. The PIV testing was carried out at the rotational speed of 6952±50 r/rain with the flow rate of 3.1 l/rain and at 8186±50 r/min with 3.5 l/rain, respectively. The velocity and the Reynolds shear stress distributions were investigated by PIV and CFD, and the comparisons between them will be helpful for the future blood pump design.