In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline....In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline. The main methods for the detection are UHF signal amplitude difference (DOA) and time difference (TOF). We analyze the localization error by using TE and TEM component and high order TE mode component in electromagnetic coaxial wave guide theory. Research and field test prove the DOA detection error can meet the requirements of real-time online diagnosis and for history tracking analysis. The error of TOF detection method can be controlled within 3% and can be applied to the site.展开更多
Objective: To assess the correlation between five anthropometric parameters and the distance from tibial tuberosity to medial malleolus in 100 volunteers. Methods: Six anthropometric parameters were measured in 50 m...Objective: To assess the correlation between five anthropometric parameters and the distance from tibial tuberosity to medial malleolus in 100 volunteers. Methods: Six anthropometric parameters were measured in 50 male and 50 female medical students using a metallic scale: medial knee joint line to ankle joint line (K-A), medial knee joint line to medial malleolus (K-MM), tibial tuberosity to ankle joint (TT-A), tibial tuberosity to medial malleolus (TT- MM), olecranon to 5th metacarpal head (O-MH) and body height (BH). Nail size predicted based upon Tr-MM measurement was chosen as ideal nail size. A constant was derived for each of the six anthropometric parameters which was either added or subtracted to each measurement to derive nail size. A regression equation was applied to BH measurements. Nail sizes calculated were compared with that obtained from TI'-MM measurement and accuracy was evaluated. Accuracy of O-MH and BH regression equations recommended by other authors were calculated in our data. Results: Adding 11 mm to Tr-A distance had highest accuracy (81%) and correlation (0.966) in predicting nails correctly. Subtracting 33 mm from K-MM measurement and 25 mm from K-A distance derived accurate sizes in 69% and 76% respectively. Adding 6 mm to O-MH distance had a poor accuracy of 51%. Nail size prediction based upon body height regression equation derived correct nail sizes in only 34% of the cases. Regression equation analysis by other authors based on O-MH and BH distances yielded correct sizes in 11% and 5% of the cases respectively. Conclusion: TT-A, K-A and K-MM measurements can be used simultaneously to increase accuracy of nail size prediction. This method would be helpful in determining nail size preoperatively especially when one anatomic landmark is difficult to palpate.展开更多
文摘In the long distance GIL under certain conditions, this paper researches and realizes detection of PD characters and accurate fault localization through UHF coupling sensors at different positions of the GIL pipeline. The main methods for the detection are UHF signal amplitude difference (DOA) and time difference (TOF). We analyze the localization error by using TE and TEM component and high order TE mode component in electromagnetic coaxial wave guide theory. Research and field test prove the DOA detection error can meet the requirements of real-time online diagnosis and for history tracking analysis. The error of TOF detection method can be controlled within 3% and can be applied to the site.
文摘Objective: To assess the correlation between five anthropometric parameters and the distance from tibial tuberosity to medial malleolus in 100 volunteers. Methods: Six anthropometric parameters were measured in 50 male and 50 female medical students using a metallic scale: medial knee joint line to ankle joint line (K-A), medial knee joint line to medial malleolus (K-MM), tibial tuberosity to ankle joint (TT-A), tibial tuberosity to medial malleolus (TT- MM), olecranon to 5th metacarpal head (O-MH) and body height (BH). Nail size predicted based upon Tr-MM measurement was chosen as ideal nail size. A constant was derived for each of the six anthropometric parameters which was either added or subtracted to each measurement to derive nail size. A regression equation was applied to BH measurements. Nail sizes calculated were compared with that obtained from TI'-MM measurement and accuracy was evaluated. Accuracy of O-MH and BH regression equations recommended by other authors were calculated in our data. Results: Adding 11 mm to Tr-A distance had highest accuracy (81%) and correlation (0.966) in predicting nails correctly. Subtracting 33 mm from K-MM measurement and 25 mm from K-A distance derived accurate sizes in 69% and 76% respectively. Adding 6 mm to O-MH distance had a poor accuracy of 51%. Nail size prediction based upon body height regression equation derived correct nail sizes in only 34% of the cases. Regression equation analysis by other authors based on O-MH and BH distances yielded correct sizes in 11% and 5% of the cases respectively. Conclusion: TT-A, K-A and K-MM measurements can be used simultaneously to increase accuracy of nail size prediction. This method would be helpful in determining nail size preoperatively especially when one anatomic landmark is difficult to palpate.