期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
一种降低导流壳式离心泵关死点扬程的方法
1
作者 李中双 符伟 +1 位作者 唐丽丽 张美芝 《水泵技术》 北大核心 2015年第2期20-22,共3页
离心泵的关死点扬程与泵的水力元件紧密相关,尤其是与叶轮和导流部件的形状有关,本文通过一个设计实例验证了一种降低导流壳式离心泵关死点扬程的设计方法。
关键词 导流壳式离心 关死点扬程 降低方法 模型 实型泵
下载PDF
Numerical and Experimental Research on the Influence of the Centrifugal Pumps Rotor Damage on Their Natural Frequency Response
2
作者 Marek Dudziński, Andrzej Grzadziela +3 位作者 Marcin Kluczyk Janusz Musial Lukasz Muslewski Michal Pajak 《Journal of Environmental Science and Engineering(B)》 2015年第3期119-124,共6页
The paper presents process of creating a centrifugal pump rotor model in CAD environment. Modeling of a virtual object was divided into two stages, modeling of the efficient pump and the simulated failure of one of th... The paper presents process of creating a centrifugal pump rotor model in CAD environment. Modeling of a virtual object was divided into two stages, modeling of the efficient pump and the simulated failure of one of the impeller's blades. Comparison of the results of the resonance frequency obtained from the model analysis, with those obtained from measurements on the actual object was shown. Measurements and simulations were conducted on the pump before and after the simulated damaged of the rotor. In order to verify the model the rotor of pump was weighted and compared with the masses of the respective components obtained from the virtual object. In the second stage genuine rotor was subjected to the experimental modal analysis. 展开更多
关键词 Centrifugal pump experimental modal analysis numerical calculations.
下载PDF
Bubble Pump Models Verification Based on the Experimental Results
3
作者 Bella Gurevich 《Journal of Energy and Power Engineering》 2017年第10期665-669,共5页
DAR (diffusion absorption refrigeration) cycle is driven by heat and has no moving parts. It is based on refrigerant and absorbent as the working fluid together with hydrogen as an auxiliary inert gas. To circulate ... DAR (diffusion absorption refrigeration) cycle is driven by heat and has no moving parts. It is based on refrigerant and absorbent as the working fluid together with hydrogen as an auxiliary inert gas. To circulate the working fluid without a mechanical pump, the diffusion absorption cycle relies on a bubble pump. Experimental system was designed and operated. Its aim was to investigate the performance of a bubble pump operating with three lifting tubes. The experimental results of the system were compared to existing models. The comparison showed that there was a bad agreement between the experimental and the theoretical results. 展开更多
关键词 Bubble pump DAR cycle multiple lift tubes binary solution.
下载PDF
上一页 1 下一页 到第