Combining separated SHPB test device of Ф50 mm with ZDKT-type 1 transient magnetic resonance test system, long drop bar of 400 mm was used to impact coal specimens at four different speeds: 1.275, 3.287, 6.251, and ...Combining separated SHPB test device of Ф50 mm with ZDKT-type 1 transient magnetic resonance test system, long drop bar of 400 mm was used to impact coal specimens at four different speeds: 1.275, 3.287, 6.251, and 7.404 m/s. The change in waveform, the dynamic mechanical properties, and the generated effect of transient field during the coal deformation and fracture under the loads were discussed and analyzed. While magnetic signals during the coal fracture firstly needed EEMD, decomposition then had a FFT with Data Demon. The main results of the experiment are the following: the main frequency of magnetic signals was between 220 and 450 kHz and the instantaneous frequency during the damage of coal would have the instantaneous jump.展开更多
The prediction method of dynamic wavelength is proposed for temperature tuning process. The temperature of the thermistor integrated in laser diode(LD) module is recorded to predict the LD chip temperature. Then accor...The prediction method of dynamic wavelength is proposed for temperature tuning process. The temperature of the thermistor integrated in laser diode(LD) module is recorded to predict the LD chip temperature. Then according to the injection current and priori tuning characteristics of the LDs, the emission wavelength is estimated in real time. The method is validated by using a 1.58 μm distributed feedback(DFB) LD. The absorption spectra of mixture gas of CO_2 and CO are measured by means of the thermal tuning gas sensing system. The center wavelength of each absorption line is compared with the data in HITRAN2012 database. The results show that the deviations are less than 5 pm. This method fully meets the needs of spectroscopic measurement, and can be applied to spectroscopy, optical communications and other fields.展开更多
文摘Combining separated SHPB test device of Ф50 mm with ZDKT-type 1 transient magnetic resonance test system, long drop bar of 400 mm was used to impact coal specimens at four different speeds: 1.275, 3.287, 6.251, and 7.404 m/s. The change in waveform, the dynamic mechanical properties, and the generated effect of transient field during the coal deformation and fracture under the loads were discussed and analyzed. While magnetic signals during the coal fracture firstly needed EEMD, decomposition then had a FFT with Data Demon. The main results of the experiment are the following: the main frequency of magnetic signals was between 220 and 450 kHz and the instantaneous frequency during the damage of coal would have the instantaneous jump.
基金supported by the National Natural Science Foundation of China(No.61505142)the Tianjin Natural Science Foundation(No.16JCQNJC02100)
文摘The prediction method of dynamic wavelength is proposed for temperature tuning process. The temperature of the thermistor integrated in laser diode(LD) module is recorded to predict the LD chip temperature. Then according to the injection current and priori tuning characteristics of the LDs, the emission wavelength is estimated in real time. The method is validated by using a 1.58 μm distributed feedback(DFB) LD. The absorption spectra of mixture gas of CO_2 and CO are measured by means of the thermal tuning gas sensing system. The center wavelength of each absorption line is compared with the data in HITRAN2012 database. The results show that the deviations are less than 5 pm. This method fully meets the needs of spectroscopic measurement, and can be applied to spectroscopy, optical communications and other fields.