期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
一种带验电功能的10kV户外接地线方法
1
作者 李一雯 虞越 +2 位作者 周聪 项伟伟 叶菁 《集成电路应用》 2020年第6期56-57,共2页
设计一种集成接触式验电和感应验电的10 kV户外接地线。接地线本体仍然是常用的10 kV双鸭舌式接地线,对于验电部分,在接地线夹的顶部位置加装了接触式验电器,具有实时验电的功能。在接地线夹手柄部分加装了电场感应式语音验电报警器。
关键词 户外接地 功能 语音 报警器 实时验电
下载PDF
Design and validation of real-time dynamic spectrum management in OFDM-based HNPLC systems 被引量:2
2
作者 刘雯静 Guo Jingbo +1 位作者 Yan Yanxin Zhang Tongfei 《High Technology Letters》 EI CAS 2015年第4期379-387,共9页
Time-varying frequency selective attenuation and colored noises are unfavorable characteristics of power line communication(PLC) channels of the low voltage networks.To overcome these disadvantages,a novel real-time d... Time-varying frequency selective attenuation and colored noises are unfavorable characteristics of power line communication(PLC) channels of the low voltage networks.To overcome these disadvantages,a novel real-time dynamic spectrum management(DSM) algorithm in orthogonal frequency division multiplexing(OFDM)-based high-speed narrow-band power line communication(HNPLC) systems is proposed,and the corresponding FPGA circuit is designed and realized.Performance of the proposed DSM is validated with a large amount of network experiments under practical PLC circumstance.As the noise in each narrow subcarrier is approximately Gaussian,the proposed DSM adopts the BER/SER expression formulized via the AWGN channel to provide a handy and universal strategy for power allocation.The real-time requirement is guaranteed by choosing subcarriers in group and employing the same modulation scheme within each transmission.These measures are suitable for any modulation scheme no matter the system criterion is to maximize data rate or minimize power/BER.Algorithm design and hardware implementation of the proposed DSM are given with some flexible and efficient conversions.The DSM circuit is carried out with Xilinx KC705.Simulation and practical experiments validate that the proposed real-time DSM significantly improves system performance. 展开更多
关键词 real-time dynamic spectrum management high-speed narrowband power line com-munication (HNPLC) subcarrier grouping rate adaptive MULTI-CARRIER
下载PDF
Automatic Voltage Regulator Test of Three Gorges Right Bank Hydropower Station 被引量:1
3
作者 Wu Tao Zhou Ji +5 位作者 Pu Jun Su Weimin Xie Huan Huo Chengxiang Deng Xiaojun Yao Qian 《Electricity》 2012年第3期24-29,共6页
Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the... Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results. 展开更多
关键词 power system stabilizers (PSS) angular speed oscillating reactance real-time digital simulation (RTDS)
下载PDF
Experimental Investigation of Solar Chimney Power Plant
4
作者 Oboetswe Motsamai Lesedi Bafetanye +1 位作者 Kobamelo Mashaba Oaitse Kgaswane 《Journal of Energy and Power Engineering》 2013年第10期1980-1984,共5页
The paper investigated the performance of a solar chimney, by measuring the chimney air temperature and velocity. A short solar chimney prototype was designed and constructed at Botswana Technology Center. A wind turb... The paper investigated the performance of a solar chimney, by measuring the chimney air temperature and velocity. A short solar chimney prototype was designed and constructed at Botswana Technology Center. A wind turbine was installed to rotate a small DC generator. Temperatures and velocities were measured at different times of the day with thermocouples and hotwire anemometer, respectively. Irradiance was measured with pyranometer. A Delta-T data logger was used to store data at intervals of 30 s. Various graphs depicting the influence of irradiance on temperature, velocity and power have been plotted. Irradiance was found to affect the chimney temperature and subsequently affects chimney air velocity and power produced. Ambient air (wind) velocity was found to have influence on the performance of the solar chimney by increasing chimney air velocity. 展开更多
关键词 Solar chimney PERFORMANCE TURBINE TEMPERATURE velocity.
下载PDF
Modeling, Experimental Study on the Heat Transfer Characteristics of Thermoelectric Generator 被引量:5
5
作者 Ze-Guang Zhou Dong-Sheng Zhu +1 位作者 Hong-Xia Wu Hong-Sheng Zhang 《Journal of Thermal Science》 SCIE EI CAS CSCD 2013年第1期48-54,共7页
This paper investigates the heat transfer characteristics of a thermoelectric generator. The influence of heat dissipation intensity to the sub-thermal resistances distribution is experimentally studied. Based on the ... This paper investigates the heat transfer characteristics of a thermoelectric generator. The influence of heat dissipation intensity to the sub-thermal resistances distribution is experimentally studied. Based on the thermal network analysis and finite time thermodynamics, an analytical model including all thermal resistances (in both thermocouples and external heat exchangers) is developed to predict the performance of the generator. The results show that the computed values of output power agree well with the experimental values. The heat transfer enhancement on the generator cold side greatly reduces the cold side temperature and thermal resistance, and obviously improves the output power. Compare with air natural convection cooling, the main thermal resistance changes from the resistance between the fins and the ambient to the thermal contact resistances between the generator and the heat sink at the conditions of forced convection and water cooling. This study may be guide the optimization of generator structure. 展开更多
关键词 thermoelectric generator thermal network thermal resistance analytical model heat transfercharacteristic output power
原文传递
A Method for Eliminating the Impact of Microwave Sweeper Power Fluctuation in BOTDA System 被引量:2
6
作者 Shuo Jiang Jun Chang +7 位作者 Sasa Zhang Zongliang Wang Sha Luo Boning Sun Xiaohui Liu Yongning Liu Junqiang Tian Chuanwu Jia 《Photonic Sensors》 SCIE EI CAS 2014年第1期86-91,共6页
The impact of microwave sweeper power fluctuation in the BOTDA system has been theoretically analyzed and experimentally tested. And a novel method comparing real-time acquisition of probe wave power with a new algori... The impact of microwave sweeper power fluctuation in the BOTDA system has been theoretically analyzed and experimentally tested. And a novel method comparing real-time acquisition of probe wave power with a new algorithm to realize probe wave power normalization for eliminating this impact was proposed. The principle of the proposed method was described theoretically. And the contrast test between our new method and conventional one was carried out. The experiment results indicated that the temperature accuracy was effectively improved from +5 C to 2 C. 展开更多
关键词 Distributed temperature sensor microwave sweeper power fluctuation temperature accuracy
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部