An optical closure study on bio-optical relationships was carried out using radiative transfer model matrix operator method developed by Freie Universitat Berlin. As a case study, the optical closure of bio-optical re...An optical closure study on bio-optical relationships was carried out using radiative transfer model matrix operator method developed by Freie Universitat Berlin. As a case study, the optical closure of bio-optical relationships empirically parameterized with in situ data for the East China Sea was examined. Remote-sensing reflectance (Rrs) was computed from the inherent optical properties predicted by these biooptical relationships and compared with published in situ data. It was found that the simulated Rrs was overestimated for turbid water. To achieve optical closure, bio-optical relationships for absorption and scattering coefficients for suspended particulate matter were adjusted. Furthermore, the results show that the Fournier and Forand phase functions obtained from the adjusted relationships perform better than the Petzold phase function. Therefore, before bio-optical relationships are used for a local sea area, the optical closure should be examined.展开更多
We label-free and real-time detected three interaction processes of antigen-antibodies,Human Immunoglobulin G(IgG),Rabbit IgG,and Mouse IgG as the targets,and Goat Anti-human IgG,Goat Anti-rabbit IgG,and Goat Anti-mou...We label-free and real-time detected three interaction processes of antigen-antibodies,Human Immunoglobulin G(IgG),Rabbit IgG,and Mouse IgG as the targets,and Goat Anti-human IgG,Goat Anti-rabbit IgG,and Goat Anti-mouse IgG as the probe,by the Oblique-incidence Reflectivity Difference(OIRD) method.The interaction dynamic curves of the OIRD signal,corresponding to the interaction processes of antigen-antibodies,are generated.The reaction times from beginning to equilibrium state are about 1800,900,and 1200 s for Human IgG,Rabbit IgG,and Mouse IgG,respectively.The experimental results demonstrate that the OIRD method not only can distinguish biomolecular interactions,but also can be used in real-time detection of interactions and dynamic processes of biomolecules.展开更多
Calibration coefficients validation is the foundation for ascertaining the sensor performance and carrying out the quantitative application.Based on the analysis of the differences between the calibration and validati...Calibration coefficients validation is the foundation for ascertaining the sensor performance and carrying out the quantitative application.Based on the analysis of the differences between the calibration and validation,two calibration coefficients validation methods were introduced in this paper.Taking the HJ-1A satellite CCD1 camera as an example,the uncertainties of calibration coefficients validation were analyzed.The calibration coefficients validation errors were simulated based on the measured data at an Inner Mongolia test site.The result showed that in the large view angle,the ground directional reflectance variation and the atmospheric path variation were the main error sources in calibration coefficients validation.The ground directional reflectance correction and atmospheric observation angle normalization should be carried out to improve the validation accuracy of calibration coefficients.展开更多
Selected Mouse IgG of 1 mg/mL as target was fabricated on microarray for 500 sample dots.Label-free and real-time reaction dynamic processes were detected between the microarrays with Goat Anti-mouse IgG of 0.02 mg/mL...Selected Mouse IgG of 1 mg/mL as target was fabricated on microarray for 500 sample dots.Label-free and real-time reaction dynamic processes were detected between the microarrays with Goat Anti-mouse IgG of 0.02 mg/mL using the obliqueincidence reflectivity difference(OIRD)method.We obtained the reaction results and the reaction dynamic curves of 500 protein dots.In addition,we also used label-free detection of protein microarrays of 10080 sample dots,including BSA and different concentrations of Mouse IgG and Rabbit IgG,by OIRD.The obtained reaction results between the protein microarray with 1 mg/mL Goat Anti-mouse IgG and 1 mg/mL Goat Anti-rabbit IgG are reported herein.Experimental results show that OIRD can be not only label-free high-throughput detection method for biological microarrays but also label-free real-time detection in the interaction processes of biomolecules.展开更多
基金Supported by the State Scholarship Fund of the China Scholarship Councilthe National Natural Science Foundation of China(Nos.60638020,41206006,41176021,41276028,41306035)+1 种基金the National Basic Research Program of China(973 Program)(No.2011CB409803,2011CB403503)the State Key Laboratory Program(No.SOED1206)
文摘An optical closure study on bio-optical relationships was carried out using radiative transfer model matrix operator method developed by Freie Universitat Berlin. As a case study, the optical closure of bio-optical relationships empirically parameterized with in situ data for the East China Sea was examined. Remote-sensing reflectance (Rrs) was computed from the inherent optical properties predicted by these biooptical relationships and compared with published in situ data. It was found that the simulated Rrs was overestimated for turbid water. To achieve optical closure, bio-optical relationships for absorption and scattering coefficients for suspended particulate matter were adjusted. Furthermore, the results show that the Fournier and Forand phase functions obtained from the adjusted relationships perform better than the Petzold phase function. Therefore, before bio-optical relationships are used for a local sea area, the optical closure should be examined.
基金supported by the National Basic Research Program of China (Grant No. 2007CB935701)
文摘We label-free and real-time detected three interaction processes of antigen-antibodies,Human Immunoglobulin G(IgG),Rabbit IgG,and Mouse IgG as the targets,and Goat Anti-human IgG,Goat Anti-rabbit IgG,and Goat Anti-mouse IgG as the probe,by the Oblique-incidence Reflectivity Difference(OIRD) method.The interaction dynamic curves of the OIRD signal,corresponding to the interaction processes of antigen-antibodies,are generated.The reaction times from beginning to equilibrium state are about 1800,900,and 1200 s for Human IgG,Rabbit IgG,and Mouse IgG,respectively.The experimental results demonstrate that the OIRD method not only can distinguish biomolecular interactions,but also can be used in real-time detection of interactions and dynamic processes of biomolecules.
基金supported by the International Science and Technology Cooperation Program of China(Grant No.2008DFA21540)the National Hi-Tech Research and Development Program of China(Grant No.2006AA12Z113)+1 种基金the Chinese Defense Advance Research Program of Science and Technologythe Young Talents Filed Special Project of Institute of Remote Sensing and Application of Chinese Academy of Sciences
文摘Calibration coefficients validation is the foundation for ascertaining the sensor performance and carrying out the quantitative application.Based on the analysis of the differences between the calibration and validation,two calibration coefficients validation methods were introduced in this paper.Taking the HJ-1A satellite CCD1 camera as an example,the uncertainties of calibration coefficients validation were analyzed.The calibration coefficients validation errors were simulated based on the measured data at an Inner Mongolia test site.The result showed that in the large view angle,the ground directional reflectance variation and the atmospheric path variation were the main error sources in calibration coefficients validation.The ground directional reflectance correction and atmospheric observation angle normalization should be carried out to improve the validation accuracy of calibration coefficients.
基金supported by the National Basic Research Program of China(Grant No.2007CB35710)
文摘Selected Mouse IgG of 1 mg/mL as target was fabricated on microarray for 500 sample dots.Label-free and real-time reaction dynamic processes were detected between the microarrays with Goat Anti-mouse IgG of 0.02 mg/mL using the obliqueincidence reflectivity difference(OIRD)method.We obtained the reaction results and the reaction dynamic curves of 500 protein dots.In addition,we also used label-free detection of protein microarrays of 10080 sample dots,including BSA and different concentrations of Mouse IgG and Rabbit IgG,by OIRD.The obtained reaction results between the protein microarray with 1 mg/mL Goat Anti-mouse IgG and 1 mg/mL Goat Anti-rabbit IgG are reported herein.Experimental results show that OIRD can be not only label-free high-throughput detection method for biological microarrays but also label-free real-time detection in the interaction processes of biomolecules.