Along with the emergence and ma- turity of 100Gbit/s technologies, numbers of trial and commercial 100Gbit/s Wavelength Division Multiplexing (WDM) systems have been established worldwide. The research- oriented lab...Along with the emergence and ma- turity of 100Gbit/s technologies, numbers of trial and commercial 100Gbit/s Wavelength Division Multiplexing (WDM) systems have been established worldwide. The research- oriented lab tests of 100Gbit/s WDM systems were done by China Unicorn in 2012. The 100Gbit/s technologies of polarization multi- plex-quadrature phase shift keying with co- herent detection from multiple vendors have been studied. There are some further issues to be specified before the commercial application of 100Gbit/s WDM system is implemented in large scale in backbone network, including optical pertbnnance parameters, optical per- lbrmance monitoring of 100Gbit/s system, protection mechanism, selection of client in- terfhce and comprehensive Operation, Ad- ministration and Maintenance (OAM).展开更多
The purpose of this study is to conduct the dryout point and heat transfer correlation for subcooled boiling flow in narrow annuli. First, the dryout point of subcooled flow boiling of water was measured in narrow ann...The purpose of this study is to conduct the dryout point and heat transfer correlation for subcooled boiling flow in narrow annuli. First, the dryout point of subcooled flow boiling of water was measured in narrow annular channels under the working condition of pressure ranging from 0.1 to 0.3 MPa and low mass flow rate from 6 to 60 kgm^-2 s^-1. Experimental test channels were annular and heated bilaterally with the channel gap of lmm and 1.5mm, and heated length of 1500mm.The location of the dryout was observed and measured by experiment with investigating the various system parameter effects on dryout point, and the results show that the location of dryout point is basically stable and repeating and the heat transfer coefficient increased with heat flux, mass flux and pressure, however, decreases with the gap size. Next, new correlations of CHF and critical vapor quality for narrow annular channels was proposed and calculation results shown a good agreement with the experimental data.展开更多
基金supported by the China Unicom under the project of the research on 100Gbit/s high bitrate transport technology
文摘Along with the emergence and ma- turity of 100Gbit/s technologies, numbers of trial and commercial 100Gbit/s Wavelength Division Multiplexing (WDM) systems have been established worldwide. The research- oriented lab tests of 100Gbit/s WDM systems were done by China Unicorn in 2012. The 100Gbit/s technologies of polarization multi- plex-quadrature phase shift keying with co- herent detection from multiple vendors have been studied. There are some further issues to be specified before the commercial application of 100Gbit/s WDM system is implemented in large scale in backbone network, including optical pertbnnance parameters, optical per- lbrmance monitoring of 100Gbit/s system, protection mechanism, selection of client in- terfhce and comprehensive Operation, Ad- ministration and Maintenance (OAM).
基金This work is supported by the Project of National Natural Science Foundation of China (No. 50076014) and the Project of Major State Basic Research Program (No. G2000026303).
文摘The purpose of this study is to conduct the dryout point and heat transfer correlation for subcooled boiling flow in narrow annuli. First, the dryout point of subcooled flow boiling of water was measured in narrow annular channels under the working condition of pressure ranging from 0.1 to 0.3 MPa and low mass flow rate from 6 to 60 kgm^-2 s^-1. Experimental test channels were annular and heated bilaterally with the channel gap of lmm and 1.5mm, and heated length of 1500mm.The location of the dryout was observed and measured by experiment with investigating the various system parameter effects on dryout point, and the results show that the location of dryout point is basically stable and repeating and the heat transfer coefficient increased with heat flux, mass flux and pressure, however, decreases with the gap size. Next, new correlations of CHF and critical vapor quality for narrow annular channels was proposed and calculation results shown a good agreement with the experimental data.