With the rapid development of economy, requirements on indoor environment design are getting higher and higher, but its prosperity brings ecological environment serious destruction and over consumption of resources. U...With the rapid development of economy, requirements on indoor environment design are getting higher and higher, but its prosperity brings ecological environment serious destruction and over consumption of resources. Under the global environment of the sustainable development, the principles of indoor environment design were analyzed ecologically and corresponding implementation methods were proposed to provide reference for energy-conservation and gas emission-reduction in the ecological system of indoor environment.展开更多
We propose a method to improve positioning accuracy while reducing energy consumption in an indoor Wireless Local Area Network(WLAN) environment.First,we intelligently and jointly select the subset of Access Points(AP...We propose a method to improve positioning accuracy while reducing energy consumption in an indoor Wireless Local Area Network(WLAN) environment.First,we intelligently and jointly select the subset of Access Points(APs) used in positioning via Maximum Mutual Information(MMI) criterion.Second,we propose Orthogonal Locality Preserving Projection(OLPP) to reduce the redundancy among selected APs.OLPP effectively extracts the intrinsic location features in situations where previous linear signal projection techniques failed to do,while maintaining computational efficiency.Third,we show that the combination of AP selection and OLPP simultaneously exploits their complementary advantages while avoiding the drawbacks.Experimental results indicate that,compared with the widely used weighted K-nearest neighbor and maximum likelihood estimation method,the proposed method leads to 21.8%(0.49 m) positioning accuracy improvement,while decreasing the computation cost by 65.4%.展开更多
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen...Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.展开更多
Building equipment, energy-saving systems, and claims of inappropriate indoor thermal environments were analyzed in relation to the floor area using responses to a questionnaire survey of service managers of 157 build...Building equipment, energy-saving systems, and claims of inappropriate indoor thermal environments were analyzed in relation to the floor area using responses to a questionnaire survey of service managers of 157 buildings built in Osaka, Kyoto and Hyogo prefectures in Kinki area of Japan. Results show the following: (1) In smaller buildings (〈 5,000 m2), setting temperatures are higher in summer and lower in winter, effects of "uncomfortable radiation from windows" are greater, energy-saving systems decrease indoor thermal comfort, but claims of "hot" and "cold" are fewer; (2) Claims of "hot" and "cold" are unrelated to the setting temperature and whether the air-conditioning control system is central or local; (3) The adoption rates of mitigation of dress codes ("COOL-BIZ" and "WARM-BIZ") are higher than those of temperature mitigation of air conditioning.展开更多
基金Supported by "Chen Guang"Project Launched by Shanghai Municipal Education Commission and Shanghai Education Development Foundation (09CGB09)~~
文摘With the rapid development of economy, requirements on indoor environment design are getting higher and higher, but its prosperity brings ecological environment serious destruction and over consumption of resources. Under the global environment of the sustainable development, the principles of indoor environment design were analyzed ecologically and corresponding implementation methods were proposed to provide reference for energy-conservation and gas emission-reduction in the ecological system of indoor environment.
基金the High-Tech Research and Development Program of China,the National Seience Foundation for Young Scientists of China,the China Postdoctoral Science Foundation funded project
文摘We propose a method to improve positioning accuracy while reducing energy consumption in an indoor Wireless Local Area Network(WLAN) environment.First,we intelligently and jointly select the subset of Access Points(APs) used in positioning via Maximum Mutual Information(MMI) criterion.Second,we propose Orthogonal Locality Preserving Projection(OLPP) to reduce the redundancy among selected APs.OLPP effectively extracts the intrinsic location features in situations where previous linear signal projection techniques failed to do,while maintaining computational efficiency.Third,we show that the combination of AP selection and OLPP simultaneously exploits their complementary advantages while avoiding the drawbacks.Experimental results indicate that,compared with the widely used weighted K-nearest neighbor and maximum likelihood estimation method,the proposed method leads to 21.8%(0.49 m) positioning accuracy improvement,while decreasing the computation cost by 65.4%.
基金Project(2011B061200043)supported by the Guangdong Provincial Department of Science and Technology,China
文摘Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.
文摘Building equipment, energy-saving systems, and claims of inappropriate indoor thermal environments were analyzed in relation to the floor area using responses to a questionnaire survey of service managers of 157 buildings built in Osaka, Kyoto and Hyogo prefectures in Kinki area of Japan. Results show the following: (1) In smaller buildings (〈 5,000 m2), setting temperatures are higher in summer and lower in winter, effects of "uncomfortable radiation from windows" are greater, energy-saving systems decrease indoor thermal comfort, but claims of "hot" and "cold" are fewer; (2) Claims of "hot" and "cold" are unrelated to the setting temperature and whether the air-conditioning control system is central or local; (3) The adoption rates of mitigation of dress codes ("COOL-BIZ" and "WARM-BIZ") are higher than those of temperature mitigation of air conditioning.