电信机房节能研究及可行性分析 被引量:8
1
作者 王泽 《电信工程技术与标准化》 2006年第6期37-39,共3页
新风在春、秋、冬季是一种天然的冷源。通信机房空调节能运行方案充分利用环境的自然资源,其本身能耗低,从其技术及改造工艺来看是成熟的,可靠性高,稳定性好。在经济技术上都是可行的。必将给电信企业带来巨大的经济效益和社会效益。
关键词 室外冷空气 机房专用空调 节能
下载PDF
Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air 被引量:5
2
作者 丁研 田喆 朱能 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期735-746,共12页
The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the ded... The hybrid system with radiant cooling and dedicated outdoor air not only possesses high energy efficiency, but also creates a healthy and comfortable indoor environment. Indoor air quality will be improved by the dedicated outdoor air system(DOAS) and indoor thermal comfort can be enhanced by the radiant cooling system(RCS). The optimal air-supply mode of the hybrid system and the corresponding design approach were investigated. A full-scale experimental chamber with various air outlets and the ceiling radiant cooling panels(CRCP) was designed and established. The performances of different air-supply modes along with CRCPs were analyzed by multi-index evaluations. Preliminary investigations were also conducted on the humidity stratification and the control effect of different airflow modes to prevent condensation on CRCP. The overhead supply air is recommended as the best combination mode for the hybrid system after comprehensive comparison of the experiment results. The optimal proportion of CRCP accounting for the total cooling capacities in accord with specific cooling loads is found, which may provide valuable reference for the design and operation of the hybrid system. 展开更多
关键词 air-supply mode hybrid system radiant cooling humidity stratification
下载PDF
Analysis of Cooling Characteristics in Datacenter Using Outdoor Air Cooling 被引量:1
3
作者 Yoshiyuki Inoue Hirofumi Hayama +2 位作者 Taro Mori Koki Kikuta Noriyuki Toyohara 《Journal of Energy and Power Engineering》 2015年第1期16-24,共9页
Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increas... Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness). 展开更多
关键词 Data center cooling characteristics outdoor air cooling PUE.