地铁引起钢结构住宅楼盖振动舒适度分析 被引量:4
1
作者 连军 曹吴臻 朱伟华 《建筑结构》 CSCD 北大核心 2022年第S02期894-897,共4页
随着经济的发展、城市化的逐步加快,地铁作为缓解交通压力的重要工具,在城市中的数量也越来越多,对其周边建筑物的振动影响也越来越引起大家的重视,以上海某紧邻地铁的拟建钢结构住宅项目为依托,通过测量场地地面振动加速度数据,并把测... 随着经济的发展、城市化的逐步加快,地铁作为缓解交通压力的重要工具,在城市中的数量也越来越多,对其周边建筑物的振动影响也越来越引起大家的重视,以上海某紧邻地铁的拟建钢结构住宅项目为依托,通过测量场地地面振动加速度数据,并把测得的外部激励输入结构整体计算模型,分析了结构的动力响应,采用规范规定的振动标准评价方法和基于烦恼率的振动评价方法对该房屋楼板跨中节点的振动情况进行了舒适度评价。 展开更多
关键词 地铁 室外振动 钢结构住宅 舒适度 烦恼率
下载PDF
Vibrational characteristics of piping system in air conditioning outdoor unit 被引量:17
2
作者 S. K. LOH W. F. FARIS +1 位作者 M. HAMDI W. M. CHIN 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第5期1154-1168,共15页
The modal analysis of piping system in air conditioner (AC) outdoor unit is essential to investigate the vibration properties of the system. In view of the growing significance of numerical finite element (FE) model f... The modal analysis of piping system in air conditioner (AC) outdoor unit is essential to investigate the vibration properties of the system. In view of the growing significance of numerical finite element (FE) model for vibration behaviour prediction, the AC piping elastic end support characterization has been explored. The axial and radial stiffness variables (ka, kr1, kr2) of the compressor-piping mounting are obtained and represented by dynamic stiffness of compressor grommet. They are obtained from dynamic load deflection test based on compressor operating condition such as excitation frequency and amplitude. The unknown stiffness variables of the other tube end (chassis-piping mounting) are determined by parameter fine tuning. An experimental modal analysis using impact hammer test has also been employed to determine the vibration properties such as natural frequencies, mode shapes and damping ratio of the piping structures. The modal parameters acquisition using SCADAS mobile acquisition system and LMS Impact Testing software is compared with the corresponding simulated modal properties using Abaqus. Most of the simulated natural frequencies achieve good correlation with the measured frequencies and it is reasonably a good prediction model to predict vibration behaviour of AC piping structures. 展开更多
关键词 air conditioning outdoor unit PIPING modal analysis vibration characteristics
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部