Well-cubic perovskite lanthanum aluminate (LaAlO3) film on (110) silicon substrate was fabricated by sol-gel method with corresponding inorganic salts. Lanthanum acetate and aluminum acetate glacial acetic acid solut...Well-cubic perovskite lanthanum aluminate (LaAlO3) film on (110) silicon substrate was fabricated by sol-gel method with corresponding inorganic salts. Lanthanum acetate and aluminum acetate glacial acetic acid solutions were prepared via ligand exchange starting from lanthanum nitrate hexahydrate and aluminum nitrate hexahydrate after being refluxed. (CH3CO)2O removed nitrates and the crystallized H2O completely, acetylacetone (AcAc) was partially bidentated with metallic ion of the metallic acetates and formed La(OAc)3 (AcAc)x, which were hydrolyzed into La(AcAc)3 (OH)x by ?x ?x adding 10 ml 0.4% methyl cellulose (MCL) solution. The La(AcAc)3 (OH)x, polymerizing and combining with MCL, ?x formed the LaAlO3 sol precursor with heteropolymeric structure and formed film easily. The epitaxial LaAlO3 film on Si(110) substrate was crystallized after being annealed in thermal annealing furnace for 650?750 °C/30 min. The mor- phologies and microstructures were characterized. The refractive index of the LAO film was 1.942 to 2.007; the dielectric constant and the dissipation factors were estimated to be 23?26 and 2.1×10?4 ? 2.4×10?4 respectively.展开更多
Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is ...Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is first application of the method to visualization of water flow in soil.We describe the principles behind the method,and then demonstrate its use with a simple laboratory infiltration experiment.32 ECVT sensors were installed on the sides of an empty PVC column.Water was poured into the column at a constant rate,and ECVT data were collected every second.The column was then packed with dry sand and again supplied with water at a constant rate with data collected every second.Data were analyzed to give bulk average water contents,which proved consistent with the water supply rates.Data were also analyzed to give 3D images(216 voxels) allowing visualization of the water distribution during the experiments.Result of this work shows that water infiltration into the soil,wall flow,progress of the unstable wetting front and the final water distribution are clearly visible.展开更多
文摘Well-cubic perovskite lanthanum aluminate (LaAlO3) film on (110) silicon substrate was fabricated by sol-gel method with corresponding inorganic salts. Lanthanum acetate and aluminum acetate glacial acetic acid solutions were prepared via ligand exchange starting from lanthanum nitrate hexahydrate and aluminum nitrate hexahydrate after being refluxed. (CH3CO)2O removed nitrates and the crystallized H2O completely, acetylacetone (AcAc) was partially bidentated with metallic ion of the metallic acetates and formed La(OAc)3 (AcAc)x, which were hydrolyzed into La(AcAc)3 (OH)x by ?x ?x adding 10 ml 0.4% methyl cellulose (MCL) solution. The La(AcAc)3 (OH)x, polymerizing and combining with MCL, ?x formed the LaAlO3 sol precursor with heteropolymeric structure and formed film easily. The epitaxial LaAlO3 film on Si(110) substrate was crystallized after being annealed in thermal annealing furnace for 650?750 °C/30 min. The mor- phologies and microstructures were characterized. The refractive index of the LAO film was 1.942 to 2.007; the dielectric constant and the dissipation factors were estimated to be 23?26 and 2.1×10?4 ? 2.4×10?4 respectively.
文摘Electrical capacitance volume tomography(ECVT) is a recently-developed technique for real-time,non-invasive 3D monitoring of processes involving materials with strong contrasts in dielectric permittivity.This work is first application of the method to visualization of water flow in soil.We describe the principles behind the method,and then demonstrate its use with a simple laboratory infiltration experiment.32 ECVT sensors were installed on the sides of an empty PVC column.Water was poured into the column at a constant rate,and ECVT data were collected every second.The column was then packed with dry sand and again supplied with water at a constant rate with data collected every second.Data were analyzed to give bulk average water contents,which proved consistent with the water supply rates.Data were also analyzed to give 3D images(216 voxels) allowing visualization of the water distribution during the experiments.Result of this work shows that water infiltration into the soil,wall flow,progress of the unstable wetting front and the final water distribution are clearly visible.