The virtual reality based motion simulation of the guide wire and the catheter inside specific vascular structures can benefit a lot for the endovascular intervention. A fast and well-performed collision cancellation ...The virtual reality based motion simulation of the guide wire and the catheter inside specific vascular structures can benefit a lot for the endovascular intervention. A fast and well-performed collision cancellation algorithm is proposed based on the geometric analysis and the angular propagation (AP), and a 3-D real-time interactive system is developed for the motion simulation of the guide wire and the catheter inside the specific patient vascular. The guide wire or the catheter is modeled as the "multi-body" representation and properties are defined by its intrinsic characteristics. The motion of the guide wire or the catheter inside the vascular is guided by the collision detection and the collision cancellation algorithm. Finally, a relaxation procedure is used to achieve more realistic status. Experimental results show that the behavior of the guide wire or the catheter depends on the defined parameters. The real-time simulation can be achieved. The result shows that the simulation system is effective and promising.展开更多
In this paper we consider the stationary multijunction device model with the avalanche effect. Using the singular perturbation method, an approximation to the current voltage curve is obtained. The cause and the condi...In this paper we consider the stationary multijunction device model with the avalanche effect. Using the singular perturbation method, an approximation to the current voltage curve is obtained. The cause and the condition for the occurrence of saturation current is analyzed. Especially, it is pointed that the avalanche effect is responsible for the blowing up of the saturation current. We prove the existence of multiple steady state solution when the ionization rate is relatively small. Finally, some numerical examples are presented to show the reliability of the theoretical results.展开更多
The effect of a guide vane installed at the elbow on flow-induced noise and vibration is investigated in the range of Reynolds numbers from 1.70×10^5 to 6.81×10^5, and the position of guide vane is determine...The effect of a guide vane installed at the elbow on flow-induced noise and vibration is investigated in the range of Reynolds numbers from 1.70×10^5 to 6.81×10^5, and the position of guide vane is determined by publications. The turbulent flow in the piping elbow is simulated with large eddy simulation (LES). Following this, a hybrid method of combining LES and Lighthill's acoustic analogy theory is used to simulate the hydrodynamic noise and sound sources are solved as volume sources in code Actran. In addition, the flow-induced vibration of the piping elbow is investigated based on a fluid-structure interaction (FSI) code. The LES results indicate that the range of vortex zone in the elbow without the guide vane is larger than the case with the guide vane, and the guide vane is effective in reducing flow-induced noise and vibration in the 90° piping elbow at different Reynolds numbers.展开更多
Two kinds of monolithically fabricated circuits are demonstrated in GaAs-based material systems using resonant tunneling diodes(RTD) and metal-semiconductor-metal photo detectors(MSM PD). The electronic characteri...Two kinds of monolithically fabricated circuits are demonstrated in GaAs-based material systems using resonant tunneling diodes(RTD) and metal-semiconductor-metal photo detectors(MSM PD). The electronic characteristics of these fabricated RTD devices,MSM devices,and integrated circuits are tested at room temperature. The results show that the current peak-to-valley ratio is 4,and the photocurrent at 5V is enhanced by a factor of nearly 9,from 2 to about 18μA by use of recessed electrodes. The working theory and logical functions of the circuits are validated.展开更多
文摘The virtual reality based motion simulation of the guide wire and the catheter inside specific vascular structures can benefit a lot for the endovascular intervention. A fast and well-performed collision cancellation algorithm is proposed based on the geometric analysis and the angular propagation (AP), and a 3-D real-time interactive system is developed for the motion simulation of the guide wire and the catheter inside the specific patient vascular. The guide wire or the catheter is modeled as the "multi-body" representation and properties are defined by its intrinsic characteristics. The motion of the guide wire or the catheter inside the vascular is guided by the collision detection and the collision cancellation algorithm. Finally, a relaxation procedure is used to achieve more realistic status. Experimental results show that the behavior of the guide wire or the catheter depends on the defined parameters. The real-time simulation can be achieved. The result shows that the simulation system is effective and promising.
文摘In this paper we consider the stationary multijunction device model with the avalanche effect. Using the singular perturbation method, an approximation to the current voltage curve is obtained. The cause and the condition for the occurrence of saturation current is analyzed. Especially, it is pointed that the avalanche effect is responsible for the blowing up of the saturation current. We prove the existence of multiple steady state solution when the ionization rate is relatively small. Finally, some numerical examples are presented to show the reliability of the theoretical results.
基金Supported by the Independent Innovation Foundation for National Defense of Huazhong University of Science and Technology(No.01-18-140019)
文摘The effect of a guide vane installed at the elbow on flow-induced noise and vibration is investigated in the range of Reynolds numbers from 1.70×10^5 to 6.81×10^5, and the position of guide vane is determined by publications. The turbulent flow in the piping elbow is simulated with large eddy simulation (LES). Following this, a hybrid method of combining LES and Lighthill's acoustic analogy theory is used to simulate the hydrodynamic noise and sound sources are solved as volume sources in code Actran. In addition, the flow-induced vibration of the piping elbow is investigated based on a fluid-structure interaction (FSI) code. The LES results indicate that the range of vortex zone in the elbow without the guide vane is larger than the case with the guide vane, and the guide vane is effective in reducing flow-induced noise and vibration in the 90° piping elbow at different Reynolds numbers.
文摘Two kinds of monolithically fabricated circuits are demonstrated in GaAs-based material systems using resonant tunneling diodes(RTD) and metal-semiconductor-metal photo detectors(MSM PD). The electronic characteristics of these fabricated RTD devices,MSM devices,and integrated circuits are tested at room temperature. The results show that the current peak-to-valley ratio is 4,and the photocurrent at 5V is enhanced by a factor of nearly 9,from 2 to about 18μA by use of recessed electrodes. The working theory and logical functions of the circuits are validated.