期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
“滨海292”轮艉侧推更新安装工艺
1
作者 吕军 《中国修船》 2002年第2期20-21,23,共3页
文章通过对“滨海 2 92”轮海损事故中艉侧推装置遭到严重破坏情况的分析 ,提出了侧推装置的选型及倒流筒体的安装 ,特别是对新老轴线与筒体的找正拉线均做了详细的工艺流程。实践证明这一工艺方法对工程降低成本 。
关键词 安装工艺 侧推装置 导流筒体 膜片式弹性联轴器 修理工艺 拖轮 船舶 “滨海292”轮
下载PDF
Effect of Mass Ratio on Hydrodynamic Response of a Flexible Cylinder
2
作者 Haoyang Cen Rupp Carriveau David S-K Ting 《Journal of Marine Science and Application》 CSCD 2016年第1期50-62,共13页
The effect of the mass ratio on the flow-induced vibration (FIV) of a flexible circular cylinder is experimentally investigated in a towing tank. A Tygon tube with outer and inner diameters of 7.9 mm and 4.8 mm, res... The effect of the mass ratio on the flow-induced vibration (FIV) of a flexible circular cylinder is experimentally investigated in a towing tank. A Tygon tube with outer and inner diameters of 7.9 mm and 4.8 mm, respectively, was employed for the study. The tube was connected to a carriage and towed from rest to a steady speed up to 1.6 m/s before slowing down to rest again over a distance of 1.6 m in still water. Reynolds number based on the cylinder's outer diameter was 800-13,000, and the reduced velocity (velocity normalized by the cylinder's natural frequency and outer diameter) spanned from 2 to 25. When connected, the cylinder was elongated from 420 mm to 460 mm under an axial pre-tension of 11 N. Based on the cylinder's elongated length, the aspect ratio (ratio of the cylinder's length to outer diameter) was calculated as 58. Three mass ratios (ratio of the cylinder's structural mass to displaced fluid mass, m*) of 0.7, 1.0, and 3.4 were determined by filling the cylinder's interior with air, water, and alloy powder (nickel-chromium-boron matrix alloy), respectively. An optical method was adopted for response measurements. Multi-frequency vibrations were observed in both in-line (IL) and cross-flow (CF) responses; at high Reynolds number, vibration modes up to the 3rd one were identified in the CF response. The mode transition was found to occur at a lower reduced velocity for the highest tested mass ratio. The vibration amplitude and frequency were quantified and expressed with respect to the reduced velocity. A significant reduced vibration amplitude was found in the IL response with increasing mass ratios, and only initial and upper branches existed in the IL and CF response amplitudes. The normalized response frequencies were revealed to linearly increase with respect to the reduced velocity, and slopes for linear relations were found to be identical for the three cases tested. 展开更多
关键词 flow-induced vibration low mass ratio flexible cylinder multi-frequency response hydrodynamic response
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部