A narrow channel setup was established and experiments were conducted to study the pre-ignition characteristics of wire insulation under overload conditions in weak buoyancy environment.The pre-ignition temperature va...A narrow channel setup was established and experiments were conducted to study the pre-ignition characteristics of wire insulation under overload conditions in weak buoyancy environment.The pre-ignition temperature variation trend of both the wire insulation and its nearby temperature monitoring points,the movement characteristics of smoke produced from the wire insulation and the ignition delay time of wire insulation were investigated.The results indicated that the narrow channel setup with a height of 10-15 mm was effective to suppress the effect of buoyancy,and the pre-ignition characteristics of wire insulation in microgravity could be predicted well by the narrow channel method.展开更多
A 25-channel 200 GHz arrayed waveguide grating (AWG) based on Si nanowire wavegnides is designed, simulated and fab- ricated. Transfer function method is used in the simulation and error analysis of AWG with width f...A 25-channel 200 GHz arrayed waveguide grating (AWG) based on Si nanowire wavegnides is designed, simulated and fab- ricated. Transfer function method is used in the simulation and error analysis of AWG with width fluctuations. The 25-channel 200 GHz AWG exhibits central channel insertion loss of 6.7 dB, crosstalk of-13 dB, and central wavelength of 1 560.55 nm. The error analysis can explain the experimental results of 25-channel 200 GHz AWG well. By using deep ul- traviolet lithography (DUV) and inductively coupled plasma etching (ICP) technologies, the devices are fabricated on sili- con-on-insulator (SOI) substrate.展开更多
Peristaltic flow of a conducting Jeffrey fluid in an inclined asymmetric channel is investigated. The channel asymmetry is produced by considering a peristaltic wave train on the flexible walls of the channel with dif...Peristaltic flow of a conducting Jeffrey fluid in an inclined asymmetric channel is investigated. The channel asymmetry is produced by considering a peristaltic wave train on the flexible walls of the channel with different amplitudes and phases. The nonlinear governing equations are solved analytically by a perturbation technique. The expressions for the stream function, axial velocity and the pressure rise per wavelength are determined in terms of the Jeffrey number λ1, the Froude number Fr, the perturbation parameter 5, the angle of inclination θ and the phase difference Ф. Effects of the physical parameters on the velocity field and the pumping characteristics are discussed. It is observed that the size of the trapping bolus increase with an increase in the magnetic parameter and the volume flow rate. That is, the magnetic parameter and the volume flow rate have strong influence on the trapping bolus phenomenon.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 50976115)the Pilot Special Programs of Chinese Academy of Sciences (Grant Nos. XDA04020208 and XDA04073202)
文摘A narrow channel setup was established and experiments were conducted to study the pre-ignition characteristics of wire insulation under overload conditions in weak buoyancy environment.The pre-ignition temperature variation trend of both the wire insulation and its nearby temperature monitoring points,the movement characteristics of smoke produced from the wire insulation and the ignition delay time of wire insulation were investigated.The results indicated that the narrow channel setup with a height of 10-15 mm was effective to suppress the effect of buoyancy,and the pre-ignition characteristics of wire insulation in microgravity could be predicted well by the narrow channel method.
基金supported by the National Key Research and Development Program of China(No.2016YFB0402504)the National Natural Science Foundation of China(Nos.61435013 and 61405188)
文摘A 25-channel 200 GHz arrayed waveguide grating (AWG) based on Si nanowire wavegnides is designed, simulated and fab- ricated. Transfer function method is used in the simulation and error analysis of AWG with width fluctuations. The 25-channel 200 GHz AWG exhibits central channel insertion loss of 6.7 dB, crosstalk of-13 dB, and central wavelength of 1 560.55 nm. The error analysis can explain the experimental results of 25-channel 200 GHz AWG well. By using deep ul- traviolet lithography (DUV) and inductively coupled plasma etching (ICP) technologies, the devices are fabricated on sili- con-on-insulator (SOI) substrate.
文摘Peristaltic flow of a conducting Jeffrey fluid in an inclined asymmetric channel is investigated. The channel asymmetry is produced by considering a peristaltic wave train on the flexible walls of the channel with different amplitudes and phases. The nonlinear governing equations are solved analytically by a perturbation technique. The expressions for the stream function, axial velocity and the pressure rise per wavelength are determined in terms of the Jeffrey number λ1, the Froude number Fr, the perturbation parameter 5, the angle of inclination θ and the phase difference Ф. Effects of the physical parameters on the velocity field and the pumping characteristics are discussed. It is observed that the size of the trapping bolus increase with an increase in the magnetic parameter and the volume flow rate. That is, the magnetic parameter and the volume flow rate have strong influence on the trapping bolus phenomenon.