期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
有限空间的尘浓度分布规律数值模拟研究 被引量:7
1
作者 徐陈又诗 张合 +2 位作者 查冰婷 郑震 陈璟宜 《兵工学报》 EI CAS CSCD 北大核心 2020年第3期618-624,共7页
针对激光引信抗尘干扰能力研究问题,提出一种尘实验室设计方案。在实验室条件下形成一个浓度均匀且可调节的尘实验平面,进而对激光引信抗尘干扰能力进行定量分析。采用k-ε湍流数学模型和离散相模型,基于混合差分格式和同位网格的压力... 针对激光引信抗尘干扰能力研究问题,提出一种尘实验室设计方案。在实验室条件下形成一个浓度均匀且可调节的尘实验平面,进而对激光引信抗尘干扰能力进行定量分析。采用k-ε湍流数学模型和离散相模型,基于混合差分格式和同位网格的压力耦合方程组半隐式方法,利用计算流体力学软件Fluent对尘实验室进行数值模拟,得到计算域内不同截面的尘浓度分布情况和浓度随时间的变化趋势。结果表明:尘平面均匀浓度受鼓风口风速和鼓料口质量流率的影响,与风速呈线性规律增长,与质量流率呈指数规律衰减;自然风可以加快尘的沉降速度。 展开更多
关键词 激光引信 尘实验室 浓度分布 有限空间 气体与固体两相流 数值模拟
下载PDF
Research on the Inert Dust against Phosphine Resistance of Cryptolestes Ferrugineus 被引量:1
2
作者 Yanyu Li Yang Cao Guangtao Li 《Journal of Life Sciences》 2011年第5期400-404,共5页
Laboratory tests were carried out in order to evaluate the efficacy of five inert dust (Puliangtai, G-1, G-2, G-3 and G-4) against the high level phosphine resistance Cryptolestesferrugineus (Stephens). The relati... Laboratory tests were carried out in order to evaluate the efficacy of five inert dust (Puliangtai, G-1, G-2, G-3 and G-4) against the high level phosphine resistance Cryptolestesferrugineus (Stephens). The relative phosphine resistance of two strains of Cryptolestesferrugineus (Stephens) was measured by the method of knockdown at 2 mg/L of phosphine. The insects were exposed to the five inert dust on filter paper inside petri dishes for 1 day at 30 ±1℃and 65 ±1% relative humidity. Then, the adults were held for 4 days with food at the same conditions without inert dust in surface bioassay. Also, they were placed in 25 ±1℃ and 65 ±1% relative humidity in grain bioassay. In surface bioassay, two strains (JXCF and YYCF) ofCryptolestesferrugineus (Stephens) were susceptible to the five inert dust at 0.08 g/m2 and 0.1 g/m2. G-3 appeared the most effective treatment against both strains, since its efficacy was 3-6 times higher than the other four inert dust tested. YYCF strain was more susceptible than JXCF, with 1-4 times higher mortality level. This research indicated that inert dusts were effective on phosphine-resistance Cryptolestesferrugineus (Stephens) populations. 展开更多
关键词 Inert dust Cryptolestesferrugineus PHOSPHINE resistance.
下载PDF
Effect of floor level slit exhaust ventilation system on distribution of house dust 被引量:1
3
作者 吕阳 H.Yoshino +3 位作者 R.Takaki R.Kurihara A.Mochida H.Yonekura 《Journal of Central South University》 SCIE EI CAS 2012年第3期696-702,共7页
Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and ... Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and floor was considered. Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system. The characteristics of airflow with experiments and computation fluid dynamics (CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet. Riboflavin particles were used as the house dust. For the spatial distribution of riboflavin particles in the ventilation system before operation, due to the influence of gravity, different sizes of particles show smooth decay curve. After floor level slit exhaust ventilation system is operated, the decay rate of the particles becomes faster than that after the ventilation system is powered on, and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement. 展开更多
关键词 house dust floor level slit exhaust riboflavin particles computational fluid dynamics
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部