The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along ...The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.展开更多
基金Supported by the National Science Foundation of Zhejiang Province.
文摘The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.