Ground Penetrating Radar method was used in detecting the flaws of underground pipeline. The GPR layer disturbing image was summarized by using a rational method in fieldwork and the in-door interpretation of data. Th...Ground Penetrating Radar method was used in detecting the flaws of underground pipeline. The GPR layer disturbing image was summarized by using a rational method in fieldwork and the in-door interpretation of data. The mark radar images of disturbance of slight, middle, and strong were obtained. The result shows that the radar method can not only determine the position of the concrete pipeline underground, but it can detect the laying quality of pipeline as well.展开更多
AIM:To measure the normal space between the posterior wall of the vagina and the anterior wall of the respectively rectum using computed tomography(CT) and reveal its were relationship to rectocele. METHODS:A total of...AIM:To measure the normal space between the posterior wall of the vagina and the anterior wall of the respectively rectum using computed tomography(CT) and reveal its were relationship to rectocele. METHODS:A total of twenty female volunteers without rectocele were examined by CT scan.We performed a middle level continuous horizontal pelvic scan from the upper part to the lower part and collected the measurement data to analyze the results using t-test. RESULTS:Twenty volunteers were enrolled in the study. The space between the posterior wall of the vagina and the anterior wall of the rectum was measured at three levels(upper 1/3,middle,lower 1/3 level of vagina). The results showed that the space from the posterior wall of the vagina to the anterior wall of the rectum at the upper 1/3 level and the middle level was 3.896 ±0.3617 mm and 4.6575±0.3052 mm,respectively. When the two groups of data were compared,we found the space at the upper 1/3 level was shorter than at the middle level(P<0.01).Moreover,at the lower 1/3 level the space measured was 10.058±0.4534 mm.The results revealed that the space at the lower 1/3 level was longer than that at the middle level(P<0.01). CONCLUSION:These measurement data may be helpful in assessing rectocele clinical diagnosis and functional outcomes of rectocele repair.展开更多
The key factor of the sensitivity in the FBG-based pH sensor is analyzed in detail. A multi-thin-layer structure of the gel coated cover was proposed and implemented with a special process. The sensors with the coated...The key factor of the sensitivity in the FBG-based pH sensor is analyzed in detail. A multi-thin-layer structure of the gel coated cover was proposed and implemented with a special process. The sensors with the coated thickness of 420 ~m, 500 ~m, and 580 ~m were built up, respectively. The corresponding spectral shifts of 0.08nm, 0.13nm, and 0.22nm were detected when the pH sensors were soaked in the pH value of 3-9. Meanwhile, the sensor with the gel layer thickness of 580 ~tm was measured in the optimum measurement time period with the pH value changing from 3-12, in which the detected sensitivity of 52pm/pH was achieved in the pH range of 6-12.展开更多
文摘Ground Penetrating Radar method was used in detecting the flaws of underground pipeline. The GPR layer disturbing image was summarized by using a rational method in fieldwork and the in-door interpretation of data. The mark radar images of disturbance of slight, middle, and strong were obtained. The result shows that the radar method can not only determine the position of the concrete pipeline underground, but it can detect the laying quality of pipeline as well.
基金Supported by The key project of Tianjin nature science foundation, China, No07JCZDJC07800
文摘AIM:To measure the normal space between the posterior wall of the vagina and the anterior wall of the respectively rectum using computed tomography(CT) and reveal its were relationship to rectocele. METHODS:A total of twenty female volunteers without rectocele were examined by CT scan.We performed a middle level continuous horizontal pelvic scan from the upper part to the lower part and collected the measurement data to analyze the results using t-test. RESULTS:Twenty volunteers were enrolled in the study. The space between the posterior wall of the vagina and the anterior wall of the rectum was measured at three levels(upper 1/3,middle,lower 1/3 level of vagina). The results showed that the space from the posterior wall of the vagina to the anterior wall of the rectum at the upper 1/3 level and the middle level was 3.896 ±0.3617 mm and 4.6575±0.3052 mm,respectively. When the two groups of data were compared,we found the space at the upper 1/3 level was shorter than at the middle level(P<0.01).Moreover,at the lower 1/3 level the space measured was 10.058±0.4534 mm.The results revealed that the space at the lower 1/3 level was longer than that at the middle level(P<0.01). CONCLUSION:These measurement data may be helpful in assessing rectocele clinical diagnosis and functional outcomes of rectocele repair.
文摘The key factor of the sensitivity in the FBG-based pH sensor is analyzed in detail. A multi-thin-layer structure of the gel coated cover was proposed and implemented with a special process. The sensors with the coated thickness of 420 ~m, 500 ~m, and 580 ~m were built up, respectively. The corresponding spectral shifts of 0.08nm, 0.13nm, and 0.22nm were detected when the pH sensors were soaked in the pH value of 3-9. Meanwhile, the sensor with the gel layer thickness of 580 ~tm was measured in the optimum measurement time period with the pH value changing from 3-12, in which the detected sensitivity of 52pm/pH was achieved in the pH range of 6-12.