Control performance monitoring has attracted great attention in both academia and industry over the past two decades. However, most research efforts have been devoted to the performance monitoring of linear control sy...Control performance monitoring has attracted great attention in both academia and industry over the past two decades. However, most research efforts have been devoted to the performance monitoring of linear control systems, without considering the pervasive nonlinearities(e.g. valve stiction) present in most industrial control systems. In this work, a novel probability distribution distance based index is proposed to monitor the performance of non-linear control systems. The proposed method uses Hellinger distance to evaluate change of control system performance. Several simulation examples are given to illustrate the effectiveness of the proposed method.展开更多
The NSLS-II (National Synchrotron Light Source II) is a state-of-the-art 3 GeV third generation light source currently under integrated testing and commissioning at Brook_haven National Laboratory. The vacuum system...The NSLS-II (National Synchrotron Light Source II) is a state-of-the-art 3 GeV third generation light source currently under integrated testing and commissioning at Brook_haven National Laboratory. The vacuum systems are monitored by vacuum gauges and ion pump current. The gate valves are controlled by PLC (programmable logic controllers) using voting scheme. EPICS (Experimental Physics and Industrial Control System) application codes provide the high level monitoring and control through the input-output controllers. This paper will discuss the commissioning status of the various aspects of vacuum control system.展开更多
基金Supported by the National Natural Science Foundation of China(61134007,61203157)the National Science Fund for Outstanding Young Scholars(61222303)+1 种基金the Fundamental Research Funds for the Central Universities(22A20151405)Shanghai R&D Platform Construction Program(13DZ2295300)
文摘Control performance monitoring has attracted great attention in both academia and industry over the past two decades. However, most research efforts have been devoted to the performance monitoring of linear control systems, without considering the pervasive nonlinearities(e.g. valve stiction) present in most industrial control systems. In this work, a novel probability distribution distance based index is proposed to monitor the performance of non-linear control systems. The proposed method uses Hellinger distance to evaluate change of control system performance. Several simulation examples are given to illustrate the effectiveness of the proposed method.
文摘The NSLS-II (National Synchrotron Light Source II) is a state-of-the-art 3 GeV third generation light source currently under integrated testing and commissioning at Brook_haven National Laboratory. The vacuum systems are monitored by vacuum gauges and ion pump current. The gate valves are controlled by PLC (programmable logic controllers) using voting scheme. EPICS (Experimental Physics and Industrial Control System) application codes provide the high level monitoring and control through the input-output controllers. This paper will discuss the commissioning status of the various aspects of vacuum control system.