The solubility and hydrolysis of carbonyl sulfide in binary mixture of diethylene glycol diethyl ether and water are studied as a function of composition. The use of an aqueous solution of diethylene glycol diethyl et...The solubility and hydrolysis of carbonyl sulfide in binary mixture of diethylene glycol diethyl ether and water are studied as a function of composition. The use of an aqueous solution of diethylene glycol diethyl ether enhances the solubility and hydrolysis rate of carbonyl sulfide compared with that in pure water. The composition of the mixture with maximum hydrolysis rate varies with temperature. The thermophysical properties including density, viscosity, and surface tension as a function of composition at 20℃ under atmospheric pressure as well as liquid-liquid equilibrium (LLE) data over the temperature range from 28℃ to 90℃ are also measured for the binary mixture.展开更多
A novel technique of flue gas desulphufization (FGD) using industrial sodium sulfide as absorbent is described to remove SO2 in flue gas. The FGD byproduct in this novel technique is sodium thiosuffate (Na2S2O3 ...A novel technique of flue gas desulphufization (FGD) using industrial sodium sulfide as absorbent is described to remove SO2 in flue gas. The FGD byproduct in this novel technique is sodium thiosuffate (Na2S2O3 · 5H2O, Hypo) which can be used as chemical raw material. Optimal operating parameters about this technique have been determined. In order to enhance productive efficiency of sodium thiosulfate, EDTA disodium additive is added into absorption solution to prevent oxidation of sodium thiosulfate. Its optimal concentration is 0. 02 wt. %. The pH value of absorption solution is set in the range of 5 ~ 6.5. Experimental results show that SO2removal efficiency averagely reach 98.72 %. The highest productive efficiency of sodium thiosulfate reaches 83.24 %. The sodium thiosulfate formed during FGD can be separated from saturated absorbent by filtration, concentration and crystallization. The filtrate after separating sodium thiosulfate will be reused as SO2 absorbent by replenishing some fresh sodium sulfide.展开更多
The "Outline of National Economic and Social Development of the 11th Five-Year Plan" has set forth the target of cutting SO2 emissions by 10% to the year 2010. To realize the target, the National Development...The "Outline of National Economic and Social Development of the 11th Five-Year Plan" has set forth the target of cutting SO2 emissions by 10% to the year 2010. To realize the target, the National Development and Reform Commission and the State Environmental Protection Administration of China jointly constituted "The 11th Five-Year Plan on SO2 Emission Control in Existing Coal-Fired Power Plants" which is not only a completing document for implementing the outline but also an important basis for the state to administer preferential policies to existing coal-fired power plants to equip desulfurization installations.展开更多
文摘The solubility and hydrolysis of carbonyl sulfide in binary mixture of diethylene glycol diethyl ether and water are studied as a function of composition. The use of an aqueous solution of diethylene glycol diethyl ether enhances the solubility and hydrolysis rate of carbonyl sulfide compared with that in pure water. The composition of the mixture with maximum hydrolysis rate varies with temperature. The thermophysical properties including density, viscosity, and surface tension as a function of composition at 20℃ under atmospheric pressure as well as liquid-liquid equilibrium (LLE) data over the temperature range from 28℃ to 90℃ are also measured for the binary mixture.
基金This research project was sponsored by National Natural Science Foundation (20877026)
文摘A novel technique of flue gas desulphufization (FGD) using industrial sodium sulfide as absorbent is described to remove SO2 in flue gas. The FGD byproduct in this novel technique is sodium thiosuffate (Na2S2O3 · 5H2O, Hypo) which can be used as chemical raw material. Optimal operating parameters about this technique have been determined. In order to enhance productive efficiency of sodium thiosulfate, EDTA disodium additive is added into absorption solution to prevent oxidation of sodium thiosulfate. Its optimal concentration is 0. 02 wt. %. The pH value of absorption solution is set in the range of 5 ~ 6.5. Experimental results show that SO2removal efficiency averagely reach 98.72 %. The highest productive efficiency of sodium thiosulfate reaches 83.24 %. The sodium thiosulfate formed during FGD can be separated from saturated absorbent by filtration, concentration and crystallization. The filtrate after separating sodium thiosulfate will be reused as SO2 absorbent by replenishing some fresh sodium sulfide.
文摘The "Outline of National Economic and Social Development of the 11th Five-Year Plan" has set forth the target of cutting SO2 emissions by 10% to the year 2010. To realize the target, the National Development and Reform Commission and the State Environmental Protection Administration of China jointly constituted "The 11th Five-Year Plan on SO2 Emission Control in Existing Coal-Fired Power Plants" which is not only a completing document for implementing the outline but also an important basis for the state to administer preferential policies to existing coal-fired power plants to equip desulfurization installations.