By measuring wetland plants chlorophyll content,malondialdehyde(MDA) content and superoxide dismutase(SOD) enzyme activity,the changes of wetland plant physiological characeristics under different power strength were ...By measuring wetland plants chlorophyll content,malondialdehyde(MDA) content and superoxide dismutase(SOD) enzyme activity,the changes of wetland plant physiological characeristics under different power strength were studied,and the mechanism of electric field on plant physiological characteristics was analyzed to provide a theoretical basis for the pollutant removal ability strengthening of artificial wetland under electricfield.The results showed that compared with the control plants,low-intensity-voltage(1 V and 3 V) had no significant effect on the normal physiological and biochemical indexes of the plants,and the growth trend was better than the control group;with the voltage increasing,plant chlorophyll content,MDA content and SOD activity were greatly affected,indicating that plants were under strong oxidative stress,and the growth was damaged.Therefore,a suitable electric field could enhance the sewage treatment effect of constructed wetland.展开更多
The results of the assessment of the influence of paper insulation on the discharge initiation in oil were presented in this paper. This assessment based on the results of performed experimental works and on the analy...The results of the assessment of the influence of paper insulation on the discharge initiation in oil were presented in this paper. This assessment based on the results of performed experimental works and on the analysis of electrical field distribution. Both types of the studies were connected with the model HV (high voltage) electrode setups covered by paper and immersed in oil. Experimental works indicated that the source of "weak points" of paper-oil model electrode setup is oil, not the surface of metal or insulation wrapping. Such hypothesis, resulting mainly from the measured times to initiations of discharges developing from bare and insulated HV electrodes, was verified by the analysis of electrical field distribution performed on the basis of finite element method applied in the COMSOL Multiphysics software. This analysis confirmed preliminary the made hypothesis. Correlation with the most stressed oil volume law was also observed.展开更多
基金Supported by Natural Science Foundation of Shanghai(10ZR1400300 )Central University Special Foundation of Basic Research and Operating expenses+1 种基金Creative Group Foundation of the National Natural Science Foundation of China (50721006)Key Discipline construction Project of Shanghai (B604)~~
文摘By measuring wetland plants chlorophyll content,malondialdehyde(MDA) content and superoxide dismutase(SOD) enzyme activity,the changes of wetland plant physiological characeristics under different power strength were studied,and the mechanism of electric field on plant physiological characteristics was analyzed to provide a theoretical basis for the pollutant removal ability strengthening of artificial wetland under electricfield.The results showed that compared with the control plants,low-intensity-voltage(1 V and 3 V) had no significant effect on the normal physiological and biochemical indexes of the plants,and the growth trend was better than the control group;with the voltage increasing,plant chlorophyll content,MDA content and SOD activity were greatly affected,indicating that plants were under strong oxidative stress,and the growth was damaged.Therefore,a suitable electric field could enhance the sewage treatment effect of constructed wetland.
文摘The results of the assessment of the influence of paper insulation on the discharge initiation in oil were presented in this paper. This assessment based on the results of performed experimental works and on the analysis of electrical field distribution. Both types of the studies were connected with the model HV (high voltage) electrode setups covered by paper and immersed in oil. Experimental works indicated that the source of "weak points" of paper-oil model electrode setup is oil, not the surface of metal or insulation wrapping. Such hypothesis, resulting mainly from the measured times to initiations of discharges developing from bare and insulated HV electrodes, was verified by the analysis of electrical field distribution performed on the basis of finite element method applied in the COMSOL Multiphysics software. This analysis confirmed preliminary the made hypothesis. Correlation with the most stressed oil volume law was also observed.