Stomatal conductance was found to change from steady-state to a slate of oscillations during daytime when vapour pressure deficit (VPD) increased to a value of 1 kPa in Glycyrrhiza inflata Batalin grown under the cond...Stomatal conductance was found to change from steady-state to a slate of oscillations during daytime when vapour pressure deficit (VPD) increased to a value of 1 kPa in Glycyrrhiza inflata Batalin grown under the conditions of arid desert in north-west China. The injected metabolic inhibitors (NaN3 or carbonyl cyanide-m-chlorophenyl-hydrazone (CCCP)) slightly reduced the stomatal conductance but did not significantly decrease the intensity of stomatal oscillations (amplitude/average). The oscillation intensity was found to he significantly correlated with VPD and root resistance, but not with the respiration rate. There might exist a minimum threshold of VPD (0.8 kPa) and root resistance (1/4 relative value) that induced stomatal oscillations. These results suggested that stomatal oscillations induced by atmospheric drought stress and root resistance were mainly a type of hydropassive movement.展开更多
A single-axis normal-tracking measurement system is proposed, which can solve the problem of measuring large curved surface. According to Collins formula, the tilt dependent error of the measurement system is studied,...A single-axis normal-tracking measurement system is proposed, which can solve the problem of measuring large curved surface. According to Collins formula, the tilt dependent error of the measurement system is studied, which uses Gaussian beam as the light source. By theoretical analysis and numerical simulation, the influence of the error is presented. The results show that there is the difference between point source and Gaussian beam for differential confocal microscopy. The opti-mal diameter of pinhole can be determined by the mathematical model and the actual parameters of the measurement system. The optimal pinhole diameter of this measurement system is 20 to 35 pm for 633 nm wavelength light source.展开更多
文摘Stomatal conductance was found to change from steady-state to a slate of oscillations during daytime when vapour pressure deficit (VPD) increased to a value of 1 kPa in Glycyrrhiza inflata Batalin grown under the conditions of arid desert in north-west China. The injected metabolic inhibitors (NaN3 or carbonyl cyanide-m-chlorophenyl-hydrazone (CCCP)) slightly reduced the stomatal conductance but did not significantly decrease the intensity of stomatal oscillations (amplitude/average). The oscillation intensity was found to he significantly correlated with VPD and root resistance, but not with the respiration rate. There might exist a minimum threshold of VPD (0.8 kPa) and root resistance (1/4 relative value) that induced stomatal oscillations. These results suggested that stomatal oscillations induced by atmospheric drought stress and root resistance were mainly a type of hydropassive movement.
基金Quantity Dissemination and Quality Safety Project of AQSIQ(No.ALC1501)National Key Scientific Instrument and Equipment Development Projects,China(No.2013YQ170539)
文摘A single-axis normal-tracking measurement system is proposed, which can solve the problem of measuring large curved surface. According to Collins formula, the tilt dependent error of the measurement system is studied, which uses Gaussian beam as the light source. By theoretical analysis and numerical simulation, the influence of the error is presented. The results show that there is the difference between point source and Gaussian beam for differential confocal microscopy. The opti-mal diameter of pinhole can be determined by the mathematical model and the actual parameters of the measurement system. The optimal pinhole diameter of this measurement system is 20 to 35 pm for 633 nm wavelength light source.