The micro-cantilever beam with a twin long period optic fiber grating sensitive to the strain and the vibration is designed to use as the sensor head.The micro-displacement of wavelength caused by strain or vibration ...The micro-cantilever beam with a twin long period optic fiber grating sensitive to the strain and the vibration is designed to use as the sensor head.The micro-displacement of wavelength caused by strain or vibration is amplified in the system.Special cladding material is used to eliminate the interference brougth about the temperature.The designing structure is enabled to detect the micro-information.展开更多
Aiming at the higher bit-rate occupation of motion vector encoding and more time load of full-searching strategies, a multi-resolution motion estimation and compensation algorithm based on adjacent prediction of frame...Aiming at the higher bit-rate occupation of motion vector encoding and more time load of full-searching strategies, a multi-resolution motion estimation and compensation algorithm based on adjacent prediction of frame difference was proposed.Differential motion detection was employed to image sequences and proper threshold was adopted to identify the connected region.Then the motion region was extracted to carry out motion estimation and motion compensation on it.The experiment results show that the encoding efficiency of motion vector is promoted, the complexity of motion estimation is reduced and the quality of the reconstruction image at the same bit-rate as Multi-Resolution Motion Estimation(MRME) is improved.展开更多
To meet the seism detection' s require of high accuracy, high resolving power, the measurement technique of Laser Doppler and detection technique of faint signal are further researched. A differential demodulation...To meet the seism detection' s require of high accuracy, high resolving power, the measurement technique of Laser Doppler and detection technique of faint signal are further researched. A differential demodulation system of Laser Doppler is designed. Phase grating is adopt to obtain same intensity measured beams with big separative angle in the system, and by focusing the waists of two Gauss beams on the measured object with extender and collimating lens group, the smallest speckle and the superposition of plane waves are obtained. And because the big diameter lens is used to collect scattered light,the Doppler signal of high SNR is obtained. It's measured range of frequency and amplitude respectively are 0.3~1000 Hz, 1.5~5mm. And the measure accuracy of amplitude and frequency respectively are 1% and 0.4%.展开更多
文摘The micro-cantilever beam with a twin long period optic fiber grating sensitive to the strain and the vibration is designed to use as the sensor head.The micro-displacement of wavelength caused by strain or vibration is amplified in the system.Special cladding material is used to eliminate the interference brougth about the temperature.The designing structure is enabled to detect the micro-information.
基金Supported by the National Natural Science Foundation of China (No. 60803036)the Scientific Research Fund of Heilongjiang Provincial Education Department (No.11531013)
文摘Aiming at the higher bit-rate occupation of motion vector encoding and more time load of full-searching strategies, a multi-resolution motion estimation and compensation algorithm based on adjacent prediction of frame difference was proposed.Differential motion detection was employed to image sequences and proper threshold was adopted to identify the connected region.Then the motion region was extracted to carry out motion estimation and motion compensation on it.The experiment results show that the encoding efficiency of motion vector is promoted, the complexity of motion estimation is reduced and the quality of the reconstruction image at the same bit-rate as Multi-Resolution Motion Estimation(MRME) is improved.
文摘To meet the seism detection' s require of high accuracy, high resolving power, the measurement technique of Laser Doppler and detection technique of faint signal are further researched. A differential demodulation system of Laser Doppler is designed. Phase grating is adopt to obtain same intensity measured beams with big separative angle in the system, and by focusing the waists of two Gauss beams on the measured object with extender and collimating lens group, the smallest speckle and the superposition of plane waves are obtained. And because the big diameter lens is used to collect scattered light,the Doppler signal of high SNR is obtained. It's measured range of frequency and amplitude respectively are 0.3~1000 Hz, 1.5~5mm. And the measure accuracy of amplitude and frequency respectively are 1% and 0.4%.