The capacities of natural and modified Brazilian bentonite samples as adsorbents to remove hexavalent metal chromium were investigated under several conditions in batch and column methods. The raw material, Ca-bentoni...The capacities of natural and modified Brazilian bentonite samples as adsorbents to remove hexavalent metal chromium were investigated under several conditions in batch and column methods. The raw material, Ca-bentonite, was modified by anchorament of 3-aminopropyltrietoxisilane (APS) and 3,2- aminoethylaminopropyltrimetoxisilane (AEAPS) in the surface of bentonite sample: This type of new occurrence of bentonite is suitable as a raw material for adsorption process. Adsorption behavior of three bentonite types was strongly depending on pH of adsorbate solution, contact time adsorbent/adsorbate, and initial concentration of Cr(VI). The results were confirmed by column method and reveals that the adsorption process of materials accorded by the Redlich-Peterson, Sips, Dubinin-Radushkevich, and tang- muir isotherm models. The exothermic entbalpic values reflected a favorable energetic process for chro- mium ions anchored in the material surfaces. The negative Gibbs free energy results supported the spontaneity of three adsorption reactions with Cr(VI) ions.展开更多
This study is to understand the impact of operating condition, especially initial operation temperature (Tini) which is set in high temperature range, on the temperature profile of the interface between PEM (polyme...This study is to understand the impact of operating condition, especially initial operation temperature (Tini) which is set in high temperature range, on the temperature profile of the interface between PEM (polymer electrolyte membrane) and catalyst layer at the cathode (i.e., the reaction surface) in a single PEFC (polymer electrolyte fuel cell). A 1D multi-plate heat transfer model based on the temperature data of separator measured using thermograph in a power generation experiment was developed to evaluate the reaction surface temperature (Treact). This study investigated the effects of flow rate, relative humidity and type of supply gas as well as Tini on the temperature distribution on reaction surface. The results obtained in 02 supply case show that, the temperature rise at the segments near the outlet of cell decreases with increasing Tini irrespective of relative humidity of supply gas (RH), while it is not seen in air supply case. Regarding the segments except near the outlet in 02 supply case, Treact - Tini increases with increasing Tini for 40% RH. The temperature distribution on reaction surface in 02 supply case is wider with increasing Tini as well as decreasing RH, though that in air supply case is relatively even.展开更多
The purpose of this study is to verify an 1D multi-plate heat-transfer model estimating the temperature distribution on the interface between polymer electrolyte membrane and catalyst layer at cathode in single cell o...The purpose of this study is to verify an 1D multi-plate heat-transfer model estimating the temperature distribution on the interface between polymer electrolyte membrane and catalyst layer at cathode in single cell of polymer electrolyte fuel cell, which is named as reaction surface in this study, with a 3D numerical simulation model solving many governing equations on the coupling phenomena in the cell. The results from both models/simulations agreed well. The effects of initial operation temperature, flow rate, and relative humidity of supply gas on temperature distribution on the reaction surface were also investigated. It was found in both 1D and 3D simulations that, the temperature rise (i.e., Treact-Tini) of the reaction surface from initial operation temperature at 70℃ was higher than that at 80℃ irrespective of flow rate of supply gas. The effect of relative humidity of supply gas on Treact- Tini near the inlet of the cell was small. Compared to the previous studies conducted under the similar operation conditions, the Treact - Tini calculated by 1D multi-plate heat-transfer model in this study as well as numerical simulation using 3D model was reasonable.展开更多
基金MCT, CNPq, and CAPES for financial supports and fellowships
文摘The capacities of natural and modified Brazilian bentonite samples as adsorbents to remove hexavalent metal chromium were investigated under several conditions in batch and column methods. The raw material, Ca-bentonite, was modified by anchorament of 3-aminopropyltrietoxisilane (APS) and 3,2- aminoethylaminopropyltrimetoxisilane (AEAPS) in the surface of bentonite sample: This type of new occurrence of bentonite is suitable as a raw material for adsorption process. Adsorption behavior of three bentonite types was strongly depending on pH of adsorbate solution, contact time adsorbent/adsorbate, and initial concentration of Cr(VI). The results were confirmed by column method and reveals that the adsorption process of materials accorded by the Redlich-Peterson, Sips, Dubinin-Radushkevich, and tang- muir isotherm models. The exothermic entbalpic values reflected a favorable energetic process for chro- mium ions anchored in the material surfaces. The negative Gibbs free energy results supported the spontaneity of three adsorption reactions with Cr(VI) ions.
文摘This study is to understand the impact of operating condition, especially initial operation temperature (Tini) which is set in high temperature range, on the temperature profile of the interface between PEM (polymer electrolyte membrane) and catalyst layer at the cathode (i.e., the reaction surface) in a single PEFC (polymer electrolyte fuel cell). A 1D multi-plate heat transfer model based on the temperature data of separator measured using thermograph in a power generation experiment was developed to evaluate the reaction surface temperature (Treact). This study investigated the effects of flow rate, relative humidity and type of supply gas as well as Tini on the temperature distribution on reaction surface. The results obtained in 02 supply case show that, the temperature rise at the segments near the outlet of cell decreases with increasing Tini irrespective of relative humidity of supply gas (RH), while it is not seen in air supply case. Regarding the segments except near the outlet in 02 supply case, Treact - Tini increases with increasing Tini for 40% RH. The temperature distribution on reaction surface in 02 supply case is wider with increasing Tini as well as decreasing RH, though that in air supply case is relatively even.
文摘The purpose of this study is to verify an 1D multi-plate heat-transfer model estimating the temperature distribution on the interface between polymer electrolyte membrane and catalyst layer at cathode in single cell of polymer electrolyte fuel cell, which is named as reaction surface in this study, with a 3D numerical simulation model solving many governing equations on the coupling phenomena in the cell. The results from both models/simulations agreed well. The effects of initial operation temperature, flow rate, and relative humidity of supply gas on temperature distribution on the reaction surface were also investigated. It was found in both 1D and 3D simulations that, the temperature rise (i.e., Treact-Tini) of the reaction surface from initial operation temperature at 70℃ was higher than that at 80℃ irrespective of flow rate of supply gas. The effect of relative humidity of supply gas on Treact- Tini near the inlet of the cell was small. Compared to the previous studies conducted under the similar operation conditions, the Treact - Tini calculated by 1D multi-plate heat-transfer model in this study as well as numerical simulation using 3D model was reasonable.