针对10 k V及以下电压等级配电网线路检修或改造过程中临时挂接地线检测问题,研究一种变频信号注入检测方法,并开发基于DSP2812的防带地线合闸检测装置,装置生成变频电压检测信号,并不断注入到检测回路中,回路由装置、线路、接地线和大...针对10 k V及以下电压等级配电网线路检修或改造过程中临时挂接地线检测问题,研究一种变频信号注入检测方法,并开发基于DSP2812的防带地线合闸检测装置,装置生成变频电压检测信号,并不断注入到检测回路中,回路由装置、线路、接地线和大地等构成,检测回路的三相电压、电流信号不断被采样,经调理后输入至CPU进行综合判断分析,从而对线路是否存在三相接地线、两相接地线、单相接地线和无接地线情况进行有效检测,并对线路相间短路情况进行识别。装置基于模块化设计,采用高速数据处理芯片,利用FFT算法分别求解基波和谐波成分,不仅可有效判断出有用信号,还可以判断线路中感应信号的强弱,现场试验表明其在技术上可有效避免"带地线合闸"这一恶性事故,有一定的参考价值。展开更多
Sensing structure of grid strip capacitors can be used in the design of capacitive micro-electromechanical system (MEMS) resonators, accelerometers etc. A grid strip structure consists of nonentirely overlap plates ...Sensing structure of grid strip capacitors can be used in the design of capacitive micro-electromechanical system (MEMS) resonators, accelerometers etc. A grid strip structure consists of nonentirely overlap plates so that the capacitor fringe effect cannot be neglected in the design. Electricmagnetic Finite Element Method (FEM) software ANSOFF-Maxwell is employed to analyze the fringe effect of a grid strip capacitor. The analysis includes capacitance changes with change of overlap length, overlap width, plate thickness, grid strip density etc. The results show that fringe effect leads to non-linear change of grid strip capacitance with the change of overlap length and width, that the capacitance increases with the increase of grid strip width and plate thickness, and that sensitivity can be improved through the increase of grid strip density in the condition of identical total overlap area, but linearity is reduced.展开更多
Based on the climate factors data and surface vapor pressure (SVP) data of 44 weather stations in Tianshan Mountains during the years 1961-2011, this paper establishes a water vapor content (WVC) estimation model ...Based on the climate factors data and surface vapor pressure (SVP) data of 44 weather stations in Tianshan Mountains during the years 1961-2011, this paper establishes a water vapor content (WVC) estimation model according to the relationship between monthly WVC of radiosonde and corresponding SVP and analyzes the spatial and temporal variability of WVC and their causes. The results show that the WVC is linearly and negatively related to the elevation and longitude (Vertical zonality and Longitude zonality), while it was not linearly related to the latitude. The westerly wind, geographical situation and sea level elevation composed complex surface conditions to influence the spatial distribution of WVC in the Tianshan Mountains. The Mann-Kendall (M-K) statistical test shows a significant increasing trend in the mean annual WVC in Tianshan Mountains during 1961- 2011(P 〈 0.001), with a rate of 0.23 mm/decade, and indicates an abrupt turning point in 1985 (P.〈0.001). Correlation analysis shows that the WVC are significantly correlated to the temperature, especially during the winter, but the summer WVC are significantly correlated to the precipitation. In addition, the North Atlantic Oscillation Index (NAOI) and the Arctic Oscillation Index (AOI) are significantly correlated to the winter WVC in the Tianshan Mountains. As a new Microwave radiometric profilers (MWRPs) instrument, the MP- 3000A provides continuous, real-time and high temporal resolution atmospheric profiles up to 10 km. In order to monitor water vapor and atmosphere profiles in Tianshan Mountains, an MP-3000A was established in Urumqi (43.8°N, 87.58°N) in May 2008. The results indicated that the MP-3oooA was applicable to this area, and the evolutionary process of water vapor and the WVC peak values of MP- 3000A were a strong signal for rainstorm and flood forecasts for Urumqi and the Tianshan Mountains.展开更多
This paper studies and analyzes the response of helical stairs as helicoidal shells in earthquake zones. The response of helical stairs under gravity loads was analyzed by both the membrane theory and finite element m...This paper studies and analyzes the response of helical stairs as helicoidal shells in earthquake zones. The response of helical stairs under gravity loads was analyzed by both the membrane theory and finite element methods. The non-linear response of helical stairs, when subjected to UBC (Uniform Building Code) dynamic and static equivalent earthquake loads, were obtained using finite element models. These responses were compiled and analyzed in order to draw recommendations for the preliminary design of helical stairs in earthquake zones. The analysis of the results obtained showed that helical stairs are stiffer and lighter than regular ones.展开更多
文摘针对10 k V及以下电压等级配电网线路检修或改造过程中临时挂接地线检测问题,研究一种变频信号注入检测方法,并开发基于DSP2812的防带地线合闸检测装置,装置生成变频电压检测信号,并不断注入到检测回路中,回路由装置、线路、接地线和大地等构成,检测回路的三相电压、电流信号不断被采样,经调理后输入至CPU进行综合判断分析,从而对线路是否存在三相接地线、两相接地线、单相接地线和无接地线情况进行有效检测,并对线路相间短路情况进行识别。装置基于模块化设计,采用高速数据处理芯片,利用FFT算法分别求解基波和谐波成分,不仅可有效判断出有用信号,还可以判断线路中感应信号的强弱,现场试验表明其在技术上可有效避免"带地线合闸"这一恶性事故,有一定的参考价值。
基金Supported by the National Natural Science Foundation of China ( No. 60903195 ) and the Key Technological Problems Tackling Project of Wuhan (No. 200750499172).
文摘Sensing structure of grid strip capacitors can be used in the design of capacitive micro-electromechanical system (MEMS) resonators, accelerometers etc. A grid strip structure consists of nonentirely overlap plates so that the capacitor fringe effect cannot be neglected in the design. Electricmagnetic Finite Element Method (FEM) software ANSOFF-Maxwell is employed to analyze the fringe effect of a grid strip capacitor. The analysis includes capacitance changes with change of overlap length, overlap width, plate thickness, grid strip density etc. The results show that fringe effect leads to non-linear change of grid strip capacitance with the change of overlap length and width, that the capacitance increases with the increase of grid strip width and plate thickness, and that sensitivity can be improved through the increase of grid strip density in the condition of identical total overlap area, but linearity is reduced.
基金sponsored by the Natural Science Foundation of China (Grant No. 41375101)the Special Fund for Meteorology-scientific Research in the Public Interest of China (Grant No. GYHY201006012)+2 种基金the Cooperation Program of National International Technological (Grant No. 2010DFA92720-14)Ministry of Water Resources Special Funds for Scientific Research on Public Causes (No.201301103)the Program for Innovative Research Team in University (Grant No. IRT1180)
文摘Based on the climate factors data and surface vapor pressure (SVP) data of 44 weather stations in Tianshan Mountains during the years 1961-2011, this paper establishes a water vapor content (WVC) estimation model according to the relationship between monthly WVC of radiosonde and corresponding SVP and analyzes the spatial and temporal variability of WVC and their causes. The results show that the WVC is linearly and negatively related to the elevation and longitude (Vertical zonality and Longitude zonality), while it was not linearly related to the latitude. The westerly wind, geographical situation and sea level elevation composed complex surface conditions to influence the spatial distribution of WVC in the Tianshan Mountains. The Mann-Kendall (M-K) statistical test shows a significant increasing trend in the mean annual WVC in Tianshan Mountains during 1961- 2011(P 〈 0.001), with a rate of 0.23 mm/decade, and indicates an abrupt turning point in 1985 (P.〈0.001). Correlation analysis shows that the WVC are significantly correlated to the temperature, especially during the winter, but the summer WVC are significantly correlated to the precipitation. In addition, the North Atlantic Oscillation Index (NAOI) and the Arctic Oscillation Index (AOI) are significantly correlated to the winter WVC in the Tianshan Mountains. As a new Microwave radiometric profilers (MWRPs) instrument, the MP- 3000A provides continuous, real-time and high temporal resolution atmospheric profiles up to 10 km. In order to monitor water vapor and atmosphere profiles in Tianshan Mountains, an MP-3000A was established in Urumqi (43.8°N, 87.58°N) in May 2008. The results indicated that the MP-3oooA was applicable to this area, and the evolutionary process of water vapor and the WVC peak values of MP- 3000A were a strong signal for rainstorm and flood forecasts for Urumqi and the Tianshan Mountains.
文摘This paper studies and analyzes the response of helical stairs as helicoidal shells in earthquake zones. The response of helical stairs under gravity loads was analyzed by both the membrane theory and finite element methods. The non-linear response of helical stairs, when subjected to UBC (Uniform Building Code) dynamic and static equivalent earthquake loads, were obtained using finite element models. These responses were compiled and analyzed in order to draw recommendations for the preliminary design of helical stairs in earthquake zones. The analysis of the results obtained showed that helical stairs are stiffer and lighter than regular ones.