A surface electromyography(sEMG)signal acquisition circuit based on high-order filtering is designed.We use a two-stage adjustable amplifier and a high-order Sallen-Key bandpass filter to solve the problems of non-adj...A surface electromyography(sEMG)signal acquisition circuit based on high-order filtering is designed.We use a two-stage adjustable amplifier and a high-order Sallen-Key bandpass filter to solve the problems of non-adjustable amplification gain and low filtering order in traditional acquisition circuits.The experimental results show that the designed sEMG signal acquisition device can eliminate power frequency interference effectively,the stopband drop of the filtering part reaches approximately-100 dB/dec,which can effectively extract useful signals between 20-500 Hz,and the amplification gain reaches 60 dB.展开更多
In this paper,we propose a securityoriented transmission scheme with the help of multiple relays in Cognitive Radio(CR).To maximise the Secrecy Capacity(SC)of the source-destination link in CR,both beamforming and coo...In this paper,we propose a securityoriented transmission scheme with the help of multiple relays in Cognitive Radio(CR).To maximise the Secrecy Capacity(SC)of the source-destination link in CR,both beamforming and cooperative jamming technologies are used to improve the performance of the Secondary User(SU)and protect the Primary User(PU).The effectiveness of the proposed scheme is demonstrated using extensive simulation.Both theoretical analyses and simulation results reveal that the proposed scheme contributes to the secure transmission of the SU with acceptable attenuation of the Signal-to-Noise Ratio(SNR)at the PU receiver,and the upper bound of the SC at the SU receiver is able to exploit the power allocation strategy.展开更多
基金Science and Technology Plan Project of Weinan City(No.2020ZDYF-JCYJ-177)Power Supply Technology Innovation Team of Shaanxi Railway Engineering Vocational and Technical College(No.KJTD201901)Graduate Program Funded Project of Shaanxi Railway Engineering Vocational and Technical College Scientific Research Fund(No.KY2018-77)。
文摘A surface electromyography(sEMG)signal acquisition circuit based on high-order filtering is designed.We use a two-stage adjustable amplifier and a high-order Sallen-Key bandpass filter to solve the problems of non-adjustable amplification gain and low filtering order in traditional acquisition circuits.The experimental results show that the designed sEMG signal acquisition device can eliminate power frequency interference effectively,the stopband drop of the filtering part reaches approximately-100 dB/dec,which can effectively extract useful signals between 20-500 Hz,and the amplification gain reaches 60 dB.
基金supported by the National Natural Science Foundation of China under Grants No. 61201150, No. 61171097the Fundamental Research Funds for the Central Universities of BUPT under Grant No. 2013RC0202the State Major Science and Technology Special Projects under Grant No. 2012ZX03004001
文摘In this paper,we propose a securityoriented transmission scheme with the help of multiple relays in Cognitive Radio(CR).To maximise the Secrecy Capacity(SC)of the source-destination link in CR,both beamforming and cooperative jamming technologies are used to improve the performance of the Secondary User(SU)and protect the Primary User(PU).The effectiveness of the proposed scheme is demonstrated using extensive simulation.Both theoretical analyses and simulation results reveal that the proposed scheme contributes to the secure transmission of the SU with acceptable attenuation of the Signal-to-Noise Ratio(SNR)at the PU receiver,and the upper bound of the SC at the SU receiver is able to exploit the power allocation strategy.