We proposed a scheme of fiber Bragg grating (FBG) sensor interrogation system based on all fiber Mach-Zehnder Interferometer (MZI) edge filter and tunable-FBG. The equal power signals from FBG sensor and tunable F...We proposed a scheme of fiber Bragg grating (FBG) sensor interrogation system based on all fiber Mach-Zehnder Interferometer (MZI) edge filter and tunable-FBG. The equal power signals from FBG sensor and tunable FBG are coupled into port 1 and port 2 of MZI respectively. The experimental results show that the interrogation precision of the proposed system is 0.02 nm in a range of I nm. Furthermore, the precision can be improved by adjusting the two interference arms of the filter.展开更多
A new modulator for the optical signal in a fiber based on multi-beam interference is designed.In the experiment,the distance of a couple of abutted fibers was modulated through a piezoelectric ceramic pipe driven by ...A new modulator for the optical signal in a fiber based on multi-beam interference is designed.In the experiment,the distance of a couple of abutted fibers was modulated through a piezoelectric ceramic pipe driven by 50 Hz AC voltage,so that the amplitude of the transmitted optical signal was modulated.The modulation ratio is about 10%,S/N ratio is about 60 dB and the bandwidth is about 200 KHz.展开更多
An interferometer based optical sensor for displacement measurement is reported. This method requires quite simple signal processing as well as least electronic components. Referring to this technique, two photodiodes...An interferometer based optical sensor for displacement measurement is reported. This method requires quite simple signal processing as well as least electronic components. Referring to this technique, two photodiodes spatially shifted by 90 degrees were used. The output of photodiodes was converted into rectangular signals which were extracted in LabVIEW using the data acquisition card without using an analog to digital converters (ADC). We have also processed the signals in C++ after acquiring via parallel port. A Michelson interferometer configuration was used to produce linear fringes for the detection of displacements. The displacement less than 100nm could be measured using this technique.展开更多
基金This study is supported by National Natural Science Foundation ofChina (No.60507007)National Basic Research Program of China(No. 2003CB314900)Program for New Century ExcellentTalents in University (NCET, Min Zhang 2007).
文摘We proposed a scheme of fiber Bragg grating (FBG) sensor interrogation system based on all fiber Mach-Zehnder Interferometer (MZI) edge filter and tunable-FBG. The equal power signals from FBG sensor and tunable FBG are coupled into port 1 and port 2 of MZI respectively. The experimental results show that the interrogation precision of the proposed system is 0.02 nm in a range of I nm. Furthermore, the precision can be improved by adjusting the two interference arms of the filter.
基金Supported by the National Nature Science Foundation of China(Grant No.60208002) the Undergraduate Innovation Projecof Nankai University.
文摘A new modulator for the optical signal in a fiber based on multi-beam interference is designed.In the experiment,the distance of a couple of abutted fibers was modulated through a piezoelectric ceramic pipe driven by 50 Hz AC voltage,so that the amplitude of the transmitted optical signal was modulated.The modulation ratio is about 10%,S/N ratio is about 60 dB and the bandwidth is about 200 KHz.
文摘An interferometer based optical sensor for displacement measurement is reported. This method requires quite simple signal processing as well as least electronic components. Referring to this technique, two photodiodes spatially shifted by 90 degrees were used. The output of photodiodes was converted into rectangular signals which were extracted in LabVIEW using the data acquisition card without using an analog to digital converters (ADC). We have also processed the signals in C++ after acquiring via parallel port. A Michelson interferometer configuration was used to produce linear fringes for the detection of displacements. The displacement less than 100nm could be measured using this technique.