期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Effects of tissue absorption on calculation of mean photon path length using modified Beer-Lambert law 被引量:1
1
作者 尚禹 桂志国 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第2期110-114,100,共6页
The mean path length(MPL)of photons is a critical parameter to calculate tissue absorption coefficient as well as blood oxygenation using modified Beer-Lambert law,where in the differential path factor(DPF)is often as... The mean path length(MPL)of photons is a critical parameter to calculate tissue absorption coefficient as well as blood oxygenation using modified Beer-Lambert law,where in the differential path factor(DPF)is often assumed as constant over range of tissue absorption.By utilizing the Monte Carlo(MC)simulation of photon migrations in the leg,this study used four approaches to estimate MPL,and compared them with that determined by the MPL definition.The simulation results indicate that the DPF is remarkably affected by tissue absorption,at approximate 10% variation.A linear model is suggested to calculate MPL for measurements of tissue absorption as well as blood oxygenation using modified Beer-Lambert law. 展开更多
关键词 mean path length(MPL) photon Monte Carlo(MC)simulation modified Beer-Lambert law tissue absorption
下载PDF
Experimental Research on Erbium-doped Superfluorescent Fiber Source 被引量:2
2
作者 CHENSheng-ping LUKe-cheng LIYi-gang LIJia-fang ZHUJian-ping FENGMing LIJing 《Semiconductor Photonics and Technology》 CAS 2004年第2期122-126,共5页
The effects of the variations in fiber length,fiber mirror reflectance on efficiency and output power are experimentally investigated for erbium-doped double pass backward superfluorescent fiber sources (SFSs).The inf... The effects of the variations in fiber length,fiber mirror reflectance on efficiency and output power are experimentally investigated for erbium-doped double pass backward superfluorescent fiber sources (SFSs).The influence of fiber length on mean wavelength stability (MWS) has also been demonstrated.By incorporating a short section of un-pumped erbium-doped fiber (EDF) at the output port,the pump power dependent on MWS becomes independent of pumped EDF length.This is a novel phenomenon that hasn’t been reported up to now,and should be helpful to SFS fabrication and theory analysis.By using a fiber Michelson interferometer as spectrum slicing component,a multi-wavelength fiber source (MWFS) with ~20 channels (from 1 542 nm to 1 559 nm) is got.The MWFS has a channel spacing of ~0.8 nm which satisfies ITU-standard.The intensity fluctuation among channels is less than 0.5 dB,and the extinction ratio of all channels is above 14 dB.This kind of MWFS should be useful to wavelength division multiplexing systems. 展开更多
关键词 Superfluorescent fiber source Erbium-doped fiber Double pass backward configuration Mean wavelength stability Multi-wavelength fiber source
下载PDF
近红外光谱组织血氧检测结果的定量化方法 被引量:7
3
作者 相韶霞 林凌 +1 位作者 王艳秋 李刚 《光学技术》 CAS CSCD 2001年第5期451-454,458,共5页
近红外光谱组织血氧检测技术可实现生物组织氧代谢的无创、连续、实时监测 ,具有广泛的应用前景。由于光在生物组织中的散射行为 ,近红外光谱组织血氧检测结果的定量问题一直是这一技术能否得到广泛应用的一个关键。文章从近红外光谱组... 近红外光谱组织血氧检测技术可实现生物组织氧代谢的无创、连续、实时监测 ,具有广泛的应用前景。由于光在生物组织中的散射行为 ,近红外光谱组织血氧检测结果的定量问题一直是这一技术能否得到广泛应用的一个关键。文章从近红外光谱组织血氧定量检测技术的理论基础和具体演算方法两方面总结至今所提出的各种算法 ,分析各种算法的特点和相应的局限性 。 展开更多
关键词 组织血氧 近红外光谱 平均光路长 光散射
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部