A novel dual-band planar microstrip filter using parallel coupled microstrip lines and open-loop stepped-impedance resonators(SIRs)loaded with two shunt open stubs is presented.By tuning the physical lengths of open...A novel dual-band planar microstrip filter using parallel coupled microstrip lines and open-loop stepped-impedance resonators(SIRs)loaded with two shunt open stubs is presented.By tuning the physical lengths of open-loop SIRs,parallel coupled microstrip lines and two stubs,the bandpass filter has good dual-passband performance at 2.55 and 5.35 GHz and high isolation between the two passbands.The relative bandwidths of the two passbands are 11.8% and 16.8%,respectively.Compared with the conventional open-loop SIR filters,the designed filter has a comparatively broader fractional bandwidth at the second passband.So it can cover all the wireless LAN(local area network)bands.In addition,the filter has the features of low loss,high rejection and low ripple.The measured results are in good agreement with the simulated responses by HFSS software.展开更多
AIM:To clarify features of hepatic hemangiomas on gadolinium-ethoxybenzyl-diethylenetriaminpentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) compared with enhanced computed tomography (CT). METH...AIM:To clarify features of hepatic hemangiomas on gadolinium-ethoxybenzyl-diethylenetriaminpentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) compared with enhanced computed tomography (CT). METHODS:Twenty-six patients with 61 hepatic hem- angiomas who underwent both Gd-EOB-DTPA-enhanced MRI and enhanced CT were retrospectively reviewed. Hemangioma appearances (presence of peripheral nodular enhancement, central nodular enhancement, diffuse homogenous enhancement, and arterioportal shunt during the arterial phase, fill-in enhancement during the portal venous phase, and prolonged enhancement during the equilibrium phase) on Gd-EOB-DTPA-enhanced MRI and enhanced CT were evaluated.The degree of contrast enhancement at the enhancing portion within the hemangioma was visually assessed using a five-point scale during each phase. For quantitative analysis, the tumor-muscle signal intensity ratio (SIR), the liver-muscle SIR, and the attenuation value of the tumor and liver parenchyma were calculated. The McNemar test and the Wilcoxon's signed rank test were used to assess the significance of differences in the appearances of hemangiomas and in the visual grade of tumor contrast enhancement between Gd-EOB-DTPA-enhanced MRI and enhanced CT. RESULTS:There was no significant difference between Gd-EOB-DTPA-enhanced MRI and enhanced CT in the presence of peripheral nodular enhancement (85% vs 82%), central nodular enhancement (3% vs 3%), diffuse enhancement (11% vs 16%), or arterioportal shunt (23% vs 34%) during arterial phase, or fill-in enhancement (79% vs 80%) during portal venous phase. Prolonged enhancement during equilibrium phase was observed less frequently on Gd-EOB-DTPA-enhanced MRI than on enhanced CT (52% vs 100%, P < 0.001). On visual inspection, there was significantly less contrast enhancement of the enhancing portion on Gd-EOB-DTPA-enhanced MRI than on enhanced CT during the arterial (3.94 ± 0.98 vs 4.57 ± 0.64, respectively, P < 0.001), portal venous (3.72 ± 0.82 vs 4.36 ± 0.53, respectively, P < 0.001), and equilibrium phases (2.01 ± 0.95 vs 4.04 ± 0.51, respectively, P < 0.001). In the quantitative analysis, the tumor-muscle SIR and the liver-muscle SIR observed with Gd-EOB-DTPA-enhanced MRI were 0.80 ± 0.24 and 1.28 ± 0.33 precontrast, 1.92 ± 0.58 and 1.57 ± 0.55 during the arterial phase, 1.87 ± 0.44 and 1.73 ± 0.39 during the portal venous phase, 1.63 ± 0.41 and 1.78 ± 0.39 during the equilibrium phase, and 1.10 ± 0.43 and 1.92 ± 0.50 during the hepatobiliary phase, respectively. The attenuation values in the tumor and liver parenchyma observed with enhanced CT were 40.60 ± 8.78 and 53.78 ± 7.37 precontrast, 172.66 ± 73.89 and 92.76 ± 17.92 during the arterial phase, 152.76 ± 35.73 and 120.12 ± 18.02 during the portal venous phase, and 108.74 ± 18.70 and 89.04 ± 7.25 during the equilibrium phase, respectively. Hemangiomas demonstrated peak enhancement during the arterial phase, and both the SIR with Gd-EOB-DTPA-enhanced MRI and the attenuation value with enhanced CT decreased with time. The SIR of hemangiomas was lower than that of liver parenchyma during the equilibrium and hepatobiliary phases on Gd-EOB-DTPA-enhanced MRI. However, the attenuation of hemangiomas after contrast injection was higher than that of liver parenchyma during all phases of enhanced CT. CONCLUSION:Prolonged enhancement during the equilibrium phase was observed less frequently on Gd-EOB-DTPA-enhanced MRI than enhanced CT, which may exacerbate differentiating between hemangiomas and malignant tumors.展开更多
The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed...The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed by conductivity probes to determine the liquid slug length distribution. The data covered both the slug and plug flow regimes. From experimental results, the mean liquid slug lengths were relatively insensitive to gas and liquid flow rates in the higher mixture velocity range. But in the lower mixture velocity range, the mean liquid slug length decreased and then increased with mixture velocity. It shows that the development length of slug flow was longer than x/D=1157. A slug tracking model was adapted to study the evolution of liquid slug length distribution in a horizontal pipeline. In the present model, the wake effect of elongated bubble and the pressure drop due to accel-eration are taken into account and random slug lengths are introduced at the entrance. The results of the model are compared with the measured slug length distributions of slug flow regime. It shows that the predicted mean and maximum slug lengths are in agreement with the experimental data at x/D=1157 and the form of the slug length distributions is also predicted well by the model.展开更多
Slug initiation and subsequem evolution along a 5.0 cm ID, 16m long horizomal pipe are experimentally studied. The transient characteristics of interfacial structures are described by using simultaneous measuremeres o...Slug initiation and subsequem evolution along a 5.0 cm ID, 16m long horizomal pipe are experimentally studied. The transient characteristics of interfacial structures are described by using simultaneous measuremeres of the liquid height at multiple locations along the pipe. Various effects of superficial gas and liquid velocities and pressure oscillation on the slug initiation and evolution along the pipe are illustrated. It is found that the slug is initiated by a deterministic orocess with reolenishmem and deoletion of liquid near the inlet for the superficial gas velocity USG〈3.0m·s^-1 and by a stochastic process with wave coalescence along the pipe for USG〉3.0m·s^-1.The evolution of the slugs is strongly attected by superhclal gas and liquid veloclties for USG〈3.0m·s^-1 but weakly affected by the superficial gas velocity for USG〉3.0 m·s . The suppression of pressure oscillation at the pipe inlet significantly delays the onset of slugging, with slugs forming postponed further downstream. The slug frequency at the outlet is, however, not affected by the variation in the pressure oscillation.展开更多
基金The National Natural Science Foundation of China(No.60621002,60702027,60921063)the National Basic Research Program of China(973Program)(No.2010CB327400)the National High Technology Research and Development Program of China(863Program)(No.2008ZX03005-001,2008AA01Z223,2009AA011503)
文摘A novel dual-band planar microstrip filter using parallel coupled microstrip lines and open-loop stepped-impedance resonators(SIRs)loaded with two shunt open stubs is presented.By tuning the physical lengths of open-loop SIRs,parallel coupled microstrip lines and two stubs,the bandpass filter has good dual-passband performance at 2.55 and 5.35 GHz and high isolation between the two passbands.The relative bandwidths of the two passbands are 11.8% and 16.8%,respectively.Compared with the conventional open-loop SIR filters,the designed filter has a comparatively broader fractional bandwidth at the second passband.So it can cover all the wireless LAN(local area network)bands.In addition,the filter has the features of low loss,high rejection and low ripple.The measured results are in good agreement with the simulated responses by HFSS software.
文摘AIM:To clarify features of hepatic hemangiomas on gadolinium-ethoxybenzyl-diethylenetriaminpentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) compared with enhanced computed tomography (CT). METHODS:Twenty-six patients with 61 hepatic hem- angiomas who underwent both Gd-EOB-DTPA-enhanced MRI and enhanced CT were retrospectively reviewed. Hemangioma appearances (presence of peripheral nodular enhancement, central nodular enhancement, diffuse homogenous enhancement, and arterioportal shunt during the arterial phase, fill-in enhancement during the portal venous phase, and prolonged enhancement during the equilibrium phase) on Gd-EOB-DTPA-enhanced MRI and enhanced CT were evaluated.The degree of contrast enhancement at the enhancing portion within the hemangioma was visually assessed using a five-point scale during each phase. For quantitative analysis, the tumor-muscle signal intensity ratio (SIR), the liver-muscle SIR, and the attenuation value of the tumor and liver parenchyma were calculated. The McNemar test and the Wilcoxon's signed rank test were used to assess the significance of differences in the appearances of hemangiomas and in the visual grade of tumor contrast enhancement between Gd-EOB-DTPA-enhanced MRI and enhanced CT. RESULTS:There was no significant difference between Gd-EOB-DTPA-enhanced MRI and enhanced CT in the presence of peripheral nodular enhancement (85% vs 82%), central nodular enhancement (3% vs 3%), diffuse enhancement (11% vs 16%), or arterioportal shunt (23% vs 34%) during arterial phase, or fill-in enhancement (79% vs 80%) during portal venous phase. Prolonged enhancement during equilibrium phase was observed less frequently on Gd-EOB-DTPA-enhanced MRI than on enhanced CT (52% vs 100%, P < 0.001). On visual inspection, there was significantly less contrast enhancement of the enhancing portion on Gd-EOB-DTPA-enhanced MRI than on enhanced CT during the arterial (3.94 ± 0.98 vs 4.57 ± 0.64, respectively, P < 0.001), portal venous (3.72 ± 0.82 vs 4.36 ± 0.53, respectively, P < 0.001), and equilibrium phases (2.01 ± 0.95 vs 4.04 ± 0.51, respectively, P < 0.001). In the quantitative analysis, the tumor-muscle SIR and the liver-muscle SIR observed with Gd-EOB-DTPA-enhanced MRI were 0.80 ± 0.24 and 1.28 ± 0.33 precontrast, 1.92 ± 0.58 and 1.57 ± 0.55 during the arterial phase, 1.87 ± 0.44 and 1.73 ± 0.39 during the portal venous phase, 1.63 ± 0.41 and 1.78 ± 0.39 during the equilibrium phase, and 1.10 ± 0.43 and 1.92 ± 0.50 during the hepatobiliary phase, respectively. The attenuation values in the tumor and liver parenchyma observed with enhanced CT were 40.60 ± 8.78 and 53.78 ± 7.37 precontrast, 172.66 ± 73.89 and 92.76 ± 17.92 during the arterial phase, 152.76 ± 35.73 and 120.12 ± 18.02 during the portal venous phase, and 108.74 ± 18.70 and 89.04 ± 7.25 during the equilibrium phase, respectively. Hemangiomas demonstrated peak enhancement during the arterial phase, and both the SIR with Gd-EOB-DTPA-enhanced MRI and the attenuation value with enhanced CT decreased with time. The SIR of hemangiomas was lower than that of liver parenchyma during the equilibrium and hepatobiliary phases on Gd-EOB-DTPA-enhanced MRI. However, the attenuation of hemangiomas after contrast injection was higher than that of liver parenchyma during all phases of enhanced CT. CONCLUSION:Prolonged enhancement during the equilibrium phase was observed less frequently on Gd-EOB-DTPA-enhanced MRI than enhanced CT, which may exacerbate differentiating between hemangiomas and malignant tumors.
基金Supported by the National Natural Science Foundation of China (No.50536020 and 50323001).
文摘The liquid slug length distribution is crucial for designing the downstream processing system with mul-tiphase pipeline. Experiments were conducted in a 133m long horizontal test loop. The measurements were per-formed by conductivity probes to determine the liquid slug length distribution. The data covered both the slug and plug flow regimes. From experimental results, the mean liquid slug lengths were relatively insensitive to gas and liquid flow rates in the higher mixture velocity range. But in the lower mixture velocity range, the mean liquid slug length decreased and then increased with mixture velocity. It shows that the development length of slug flow was longer than x/D=1157. A slug tracking model was adapted to study the evolution of liquid slug length distribution in a horizontal pipeline. In the present model, the wake effect of elongated bubble and the pressure drop due to accel-eration are taken into account and random slug lengths are introduced at the entrance. The results of the model are compared with the measured slug length distributions of slug flow regime. It shows that the predicted mean and maximum slug lengths are in agreement with the experimental data at x/D=1157 and the form of the slug length distributions is also predicted well by the model.
基金Supported by the National Natural Science Foundation of China (50521604) and the State Key Development Program for Basic Research of China (2007CB029804).
文摘Slug initiation and subsequem evolution along a 5.0 cm ID, 16m long horizomal pipe are experimentally studied. The transient characteristics of interfacial structures are described by using simultaneous measuremeres of the liquid height at multiple locations along the pipe. Various effects of superficial gas and liquid velocities and pressure oscillation on the slug initiation and evolution along the pipe are illustrated. It is found that the slug is initiated by a deterministic orocess with reolenishmem and deoletion of liquid near the inlet for the superficial gas velocity USG〈3.0m·s^-1 and by a stochastic process with wave coalescence along the pipe for USG〉3.0m·s^-1.The evolution of the slugs is strongly attected by superhclal gas and liquid veloclties for USG〈3.0m·s^-1 but weakly affected by the superficial gas velocity for USG〉3.0 m·s . The suppression of pressure oscillation at the pipe inlet significantly delays the onset of slugging, with slugs forming postponed further downstream. The slug frequency at the outlet is, however, not affected by the variation in the pressure oscillation.