The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process...The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process of"IRABF + high-efficiency fiber filtering + disinfection" to make the wastewater quality comply with the quality of recycled cooling water, so that the technique for reused petrochemical wastewater was more reliable technically and more reasonable economically,展开更多
TOR (Tema oil refinery) is the only petroleum refinery in Ghana. To assess the quality of the wastewater, wastewater samples taken from three points of discharge into the treatment plant and the treated effluent wer...TOR (Tema oil refinery) is the only petroleum refinery in Ghana. To assess the quality of the wastewater, wastewater samples taken from three points of discharge into the treatment plant and the treated effluent were analyzed for physico-chemical characteristics. The levels of the pH, temperature, conductivity, COD (Chemical Oxygen Demand), TDS (Total Dissolved Solids), TSS (Total Suspended Solids) and phenol were assessed from January to June, 2011. The results obtained indicate varied levels of contaminants in both the untreated and treated wastewater. The average values of the treated effluent parameters analyzed were 38 ℃, 6,258 μs.cm-1, 314 mg-L-1, 115 mg.L-1, 2,689 mg-L-1 and 1 mg.L-1 for the temperature, conductivity, COD, TDS, TSS and phenol, respectively. The results suggest that both the raw wastewater and the treated effluent did not meet the discharge limit set by Ghana Environmental Protection Agency. Therefore, the treated effluent required additional treatment before it can be discharged into the environment. This suggests that the wastewater treatment plant of TOR is ineffective for the type of wastewater produced.展开更多
文摘The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process of"IRABF + high-efficiency fiber filtering + disinfection" to make the wastewater quality comply with the quality of recycled cooling water, so that the technique for reused petrochemical wastewater was more reliable technically and more reasonable economically,
文摘TOR (Tema oil refinery) is the only petroleum refinery in Ghana. To assess the quality of the wastewater, wastewater samples taken from three points of discharge into the treatment plant and the treated effluent were analyzed for physico-chemical characteristics. The levels of the pH, temperature, conductivity, COD (Chemical Oxygen Demand), TDS (Total Dissolved Solids), TSS (Total Suspended Solids) and phenol were assessed from January to June, 2011. The results obtained indicate varied levels of contaminants in both the untreated and treated wastewater. The average values of the treated effluent parameters analyzed were 38 ℃, 6,258 μs.cm-1, 314 mg-L-1, 115 mg.L-1, 2,689 mg-L-1 and 1 mg.L-1 for the temperature, conductivity, COD, TDS, TSS and phenol, respectively. The results suggest that both the raw wastewater and the treated effluent did not meet the discharge limit set by Ghana Environmental Protection Agency. Therefore, the treated effluent required additional treatment before it can be discharged into the environment. This suggests that the wastewater treatment plant of TOR is ineffective for the type of wastewater produced.