We estimate the correction of relativistic center-of-mass vector on electric polarizability of an equal-mass quark-antiquark system numerically. Effect on the system confined by different interactive potentials is ana...We estimate the correction of relativistic center-of-mass vector on electric polarizability of an equal-mass quark-antiquark system numerically. Effect on the system confined by different interactive potentials is analysed. A great improvement for the electric polarizability of pion meson is obtained.展开更多
A new image reconstruction method was developed for a Compton camera. A simulation to determine a γ-ray source position was performed by using the simulation tool, GEANT4. An image reconstruction was made in two step...A new image reconstruction method was developed for a Compton camera. A simulation to determine a γ-ray source position was performed by using the simulation tool, GEANT4. An image reconstruction was made in two steps. First, a three dimensional image was constructed and projected in one selected plane, then the points from each ellipse was picked up by taking the peak points of a density distribution of crossing points between the ellipse and the first step image. The second step procedure improved the accuracy and the spatial resolution of a position de- termination significantly, comparing with the image obtained by only the first step. The accuracy and the resolution for a point source were obtained to be about 0.02 mm and (1.35±0.15) mm, respectively. The same procedure was applied to an imaging of the distributed γ-ray source.展开更多
基金国家自然科学基金,the Institute of Theoretical Physics,中国科学院知识创新工程项目
文摘We estimate the correction of relativistic center-of-mass vector on electric polarizability of an equal-mass quark-antiquark system numerically. Effect on the system confined by different interactive potentials is analysed. A great improvement for the electric polarizability of pion meson is obtained.
文摘A new image reconstruction method was developed for a Compton camera. A simulation to determine a γ-ray source position was performed by using the simulation tool, GEANT4. An image reconstruction was made in two steps. First, a three dimensional image was constructed and projected in one selected plane, then the points from each ellipse was picked up by taking the peak points of a density distribution of crossing points between the ellipse and the first step image. The second step procedure improved the accuracy and the spatial resolution of a position de- termination significantly, comparing with the image obtained by only the first step. The accuracy and the resolution for a point source were obtained to be about 0.02 mm and (1.35±0.15) mm, respectively. The same procedure was applied to an imaging of the distributed γ-ray source.