[Objection] The aim was to study application of channels constructed wetland in treatment of domestic sewages in new countryside. [Method] Supported by construction of new rural areas project in China, we surveyed on ...[Objection] The aim was to study application of channels constructed wetland in treatment of domestic sewages in new countryside. [Method] Supported by construction of new rural areas project in China, we surveyed on new rural areas in Gannan, Jiangxi Province, summarized source, characteristics and treatment of domestic sewage in countryside, and designed channels constructed wetland for sewage treatment. [Result] The technique is proven effective in sewage treatment. After the technique was conducted for a trial run for four months, removal rates of COD, TP and TN averaged 73.07%, 73.25% and 72.36%, respectively. After contin- uous sampling for six times, effluent COD was analyzed 20-35 mg/L, TP was 0.60- 1.19 mg/L and TN was 6.88-11.21 mg/L, better than that of Standard 1B ruled by Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant. [Conclusion] Thanks for low investment, channels constructed wetland can be built by trans- formation of bottom land, proving a good way for treatment of diffuse pollution source and control of water non-point pollution.展开更多
基金Supported by Project of the National Eleventh-Five Year Research Program of China(2008BAD96B04)~~
文摘[Objection] The aim was to study application of channels constructed wetland in treatment of domestic sewages in new countryside. [Method] Supported by construction of new rural areas project in China, we surveyed on new rural areas in Gannan, Jiangxi Province, summarized source, characteristics and treatment of domestic sewage in countryside, and designed channels constructed wetland for sewage treatment. [Result] The technique is proven effective in sewage treatment. After the technique was conducted for a trial run for four months, removal rates of COD, TP and TN averaged 73.07%, 73.25% and 72.36%, respectively. After contin- uous sampling for six times, effluent COD was analyzed 20-35 mg/L, TP was 0.60- 1.19 mg/L and TN was 6.88-11.21 mg/L, better than that of Standard 1B ruled by Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant. [Conclusion] Thanks for low investment, channels constructed wetland can be built by trans- formation of bottom land, proving a good way for treatment of diffuse pollution source and control of water non-point pollution.