Based on comparative test of two transfer story models, in one of which the transfer beam and basement column is constructed of steel reinforced concrete, and the other is constructed of ordinary reinforced concrete, ...Based on comparative test of two transfer story models, in one of which the transfer beam and basement column is constructed of steel reinforced concrete, and the other is constructed of ordinary reinforced concrete, its force behavior, ductility and failure mechanism under vertical and horizontal loads are studied. The results show that loading bearing and seismic behavior of transfer story structure with steel reinforced concrete beam and basement column is good. The relative design suggestion is put forward.展开更多
This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm ...This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm in diameter with 10 mm spacing. The aim is to increase bonding capacity by having small studs. Five beams with the dimension of 100 mm x 200 mm x 3,000 mm were tested where one of the beams was used as control beam (unstrengthened). The remaining beams were strengthened with different configurations before tested to failure under four-point loading. The results showed that the ductility was increased as the percentage of CFRP increased. The ductility was dramatically improved where the highest ductility index based on deflection method was 2.2 where the percentage increase was 37.5%, whereas the highest ductility index based on energy method was 3.2 where the percentage increase was 88.2%. From this study, it was found that 0.3% is the optimum value of CFRP area to achieve maximum ductility index. Ductility index obtained from energy method gives higher values when compared to deflection method. All beams in this study did not fail due to peel off or debonding. It was also proved that the spikes that have been made at the wood surface were very effective for bonding.展开更多
Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crashing of ro...Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crashing of roof concrete, respectively. The ductility indexes of the box girder and hollow slab were 1.99 and 1.23, respectively, according to the energy viewpoint. Based on the horizontal section hypothesis, the nonlinear computation procedure was established using the limited banding law, and it could carry out the entire performance analysis including the unloading, mainly focusing on the ways to achieve the unloading curves computation through stress-strain, moment-curvature and load-displacement curves. Through the procedure, parameters that influence on the bearing capacity, deformation performance and ductility of the structures were analyzed. Those parameters were quantity of prestressed reinforcement and tension coefficients of prestressed reinforcement. From the analysis, some useful conclusions can be obtained.展开更多
文摘Based on comparative test of two transfer story models, in one of which the transfer beam and basement column is constructed of steel reinforced concrete, and the other is constructed of ordinary reinforced concrete, its force behavior, ductility and failure mechanism under vertical and horizontal loads are studied. The results show that loading bearing and seismic behavior of transfer story structure with steel reinforced concrete beam and basement column is good. The relative design suggestion is put forward.
文摘This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm in diameter with 10 mm spacing. The aim is to increase bonding capacity by having small studs. Five beams with the dimension of 100 mm x 200 mm x 3,000 mm were tested where one of the beams was used as control beam (unstrengthened). The remaining beams were strengthened with different configurations before tested to failure under four-point loading. The results showed that the ductility was increased as the percentage of CFRP increased. The ductility was dramatically improved where the highest ductility index based on deflection method was 2.2 where the percentage increase was 37.5%, whereas the highest ductility index based on energy method was 3.2 where the percentage increase was 88.2%. From this study, it was found that 0.3% is the optimum value of CFRP area to achieve maximum ductility index. Ductility index obtained from energy method gives higher values when compared to deflection method. All beams in this study did not fail due to peel off or debonding. It was also proved that the spikes that have been made at the wood surface were very effective for bonding.
基金National Natural Science Foundation of China(No.50678063)
文摘Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crashing of roof concrete, respectively. The ductility indexes of the box girder and hollow slab were 1.99 and 1.23, respectively, according to the energy viewpoint. Based on the horizontal section hypothesis, the nonlinear computation procedure was established using the limited banding law, and it could carry out the entire performance analysis including the unloading, mainly focusing on the ways to achieve the unloading curves computation through stress-strain, moment-curvature and load-displacement curves. Through the procedure, parameters that influence on the bearing capacity, deformation performance and ductility of the structures were analyzed. Those parameters were quantity of prestressed reinforcement and tension coefficients of prestressed reinforcement. From the analysis, some useful conclusions can be obtained.