期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
伪邻近点法分析薄膜磁致伸缩测试中异常数据 被引量:1
1
作者 唐军 杨仕清 +3 位作者 张万里 蒋洪川 彭斌 陈志川 《计量学报》 EI CSCD 北大核心 2007年第1期74-76,共3页
采用伪邻近点法,对薄膜磁致伸缩系数测试试验中得到的不同性质的测试数据分别进行处理,发现它们具有确定性的特征,从而可得测试中异常状态基本由系统本身引起,这样通过调节及改进测试系统就能减小其影响,得到较为可靠的光点位移数据。
关键词 计量学 磁致伸缩 伪邻近点法 白噪声 延时重构 嵌入维数
下载PDF
Nonlinear characteristics and functional analysis of masseter electromyography
2
作者 胡昕 吴箫博 +3 位作者 邹波 傅予力 喻意 卢广文 《Journal of Central South University》 SCIE EI CAS 2011年第3期834-839,共6页
The C-C method was adopted to analyze the nonlinear characteristics of masseter electromyography (EMG) signals and the chaotic degree by the largest Lyapunov exponent (LLE) of different genders and sides. First, t... The C-C method was adopted to analyze the nonlinear characteristics of masseter electromyography (EMG) signals and the chaotic degree by the largest Lyapunov exponent (LLE) of different genders and sides. First, the embedding dimension and the delay time were obtained through this method, then the phase space was reconstructed to resume the chaotie attractor and determine the LLE. The result shows that the trajectory of attractor is denser than Chen's attractor, and the LLE is positive, which means that not only the signal has the character of chaos, but also the chaotic degree of masseter EMG is relatively high. According to the value of the LLE, the chaotic degree of men's masseter EMG is higher than that of women's; when the dentition is normal, the chaotic degree of two sides is almost the same. Then, a conclusion can be deduced that if the LLE of both sides are in great difference, the unilateral mastication is likely to exist, which means that the nonlinear characteristics of masseter EMG can be applied to predict the unilateral mastication. 展开更多
关键词 nonlinear characteristic masseter electromyograph C-C Method phase space reconstruction ATTRACTOR Lyapunovexponent
下载PDF
Determination of delay time in individual transfer function for central aortic pressure reconstruction
3
作者 YU DanYang XIANG HaiYan +2 位作者 LI DeYu WANG YuQi YU MengSun 《Science China(Life Sciences)》 SCIE CAS 2014年第10期1034-1038,共5页
In previous research, time-delay (△t) was a more important parameter than the reflection coefficient in the individual transfer function of central aortic pressure reconstruction. The At can be obtained by electroc... In previous research, time-delay (△t) was a more important parameter than the reflection coefficient in the individual transfer function of central aortic pressure reconstruction. The At can be obtained by electrocardiography (ECG) or phonocardiography (PCG). Because the pre-ejection period remains an uncertain factor, the present study used ECG and PCG to define the delay time and analyzed the accuracy of the reconstruction results. The △tpre is the actual delay time derived from the aorta to the carotid pressure wave, △tpco is the time delay between the aortic valve component of the second heart sound and the dicrotic incisura of the carotid pressure wave, and AtEcc represents the delay from the interval of the ECG R-peak to the foot of the carotid pressure wave. Compared with the measured aortic pressure, the reconstruction result obtained by △t=△tpcslightly differed from the best result estimated by △t=△tpre. However, the differences between the result obtained by △t=△tEco and the best result were significant in terms of the diastolic blood pressure, and pulse pressure, and especially in terms of the augmentation index and root-mean-square-error. Thus, the At should be determined by PCG for central aortic pressure reconstruction in practice. 展开更多
关键词 central aortic pressure delay time PCG ECG
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部