To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,...To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ.展开更多
Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numer...Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numerically investigated. Three levels of Rayleigh number(5.8×1010, 1.0×1012 and 2.1×1012) and two values of source contaminant flux(5 mg/s and 50 mg/s) were considered. The inlet Reynolds numbers were 2×104, 5×104, 1.5×105 and 4.5×105 for DV and 5×105, 1×106, 2×106 and 4×106 for PV, respectively. From the results, it is concluded that the above parameters have very complex impacts on the conjugated heat and mass transports. From points of view of acceptable indoor air quality and ventilation efficiency, PV at Re=1×106 with side-located sources and 65% of the supply air extracted through floor level outlets is the best choice when Ra=5.8×1010. However, DVs at Re=5×104 and Re=1.5×105with center-located sources and floor-mounted air suppliers are the best choices for Ra=1.0×1012 and Ra=2.1×1012, respectively. When source contaminant flux reaches 50 mg/s, local extraction as a supplement of general ventilation is recommended. The results can be a first approximation to 3D numerical investigation and preliminary ventilation system design guidelines for high-rise industrial halls.展开更多
Indoor Environmental Quality (IEQ) deals with providing a healthy and comfortable indoor environment. Most of international sustainability rating systems consider IEQ as a key perspective for developing sustainable ...Indoor Environmental Quality (IEQ) deals with providing a healthy and comfortable indoor environment. Most of international sustainability rating systems consider IEQ as a key perspective for developing sustainable buildings. Educational buildings include large number of people which increase the need to provide appropriate IEQ. Accordingly, there is a critical need to frequently assess of IEQ in this type of buildings in order to maintain the satisfactory level of IEQ. This paper aims to develop a framework for assessing and improving the IEQ of educational buildings in Saudi Arabia through measuring the IEQ parameters and integrating these results with Building Information Modeling (BIM). The key IEQ parameters considered in this study include thermal comfort, indoor air quality and visual comfort. These parameters have been measured by comfort-sense system, indoor air quality meter and light meter respectively. The measured data are integrated with BIM model in order to track the IEQ problems, and to develop IEQ history over time. By using the proposed framework, the IEQ can be tracked and improved. The IEQ assessment framework has been implemented on educational building in Saudi Arabia as a case study to validate the process and perform the necessary modifications and improvements.展开更多
Daylighting studies in buildings are key parts of environmental analysis and can be easily conducted at the early stages of design as part of environmentally responsive building design as well as to inform the final a...Daylighting studies in buildings are key parts of environmental analysis and can be easily conducted at the early stages of design as part of environmentally responsive building design as well as to inform the final architectural layout and interior design. The main aim of this study is to demonstrate how such daylighting studies can be completed at the early stages of design and, at the same time, to show the impact of window design and positioning on building indoor environments. The paper is focused on a study of window influence on room daylighting in residential buildings and computer lighting simulations in software packages: Windows Daylighting System and Autodesk Ecotect Analysis, have been carried out for different style and positioning of windows using several case studies. The main findings clearly indicated that not only the window size and style matters, but also the positioning of windows considering external walls which would make a significant influence on room daylighting levels and, therefore, such daylight studies are very important for the early stage of environmental analysis during building design.展开更多
基金The National Natural Science Foundation of China(No.50878078)
文摘To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ.
基金Project(2011BAJ03B07)supported by National Twelve Five-year Science and Technology Support Program of ChinaProject supported by the China Scholarship Council+1 种基金Project(51276057,51376198)supported by the National Natural Science Foundation of ChinaProject(CX2014B064)supported by Hunan Provincial Innovation Foundation for Postgraduate,China
文摘Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numerically investigated. Three levels of Rayleigh number(5.8×1010, 1.0×1012 and 2.1×1012) and two values of source contaminant flux(5 mg/s and 50 mg/s) were considered. The inlet Reynolds numbers were 2×104, 5×104, 1.5×105 and 4.5×105 for DV and 5×105, 1×106, 2×106 and 4×106 for PV, respectively. From the results, it is concluded that the above parameters have very complex impacts on the conjugated heat and mass transports. From points of view of acceptable indoor air quality and ventilation efficiency, PV at Re=1×106 with side-located sources and 65% of the supply air extracted through floor level outlets is the best choice when Ra=5.8×1010. However, DVs at Re=5×104 and Re=1.5×105with center-located sources and floor-mounted air suppliers are the best choices for Ra=1.0×1012 and Ra=2.1×1012, respectively. When source contaminant flux reaches 50 mg/s, local extraction as a supplement of general ventilation is recommended. The results can be a first approximation to 3D numerical investigation and preliminary ventilation system design guidelines for high-rise industrial halls.
文摘Indoor Environmental Quality (IEQ) deals with providing a healthy and comfortable indoor environment. Most of international sustainability rating systems consider IEQ as a key perspective for developing sustainable buildings. Educational buildings include large number of people which increase the need to provide appropriate IEQ. Accordingly, there is a critical need to frequently assess of IEQ in this type of buildings in order to maintain the satisfactory level of IEQ. This paper aims to develop a framework for assessing and improving the IEQ of educational buildings in Saudi Arabia through measuring the IEQ parameters and integrating these results with Building Information Modeling (BIM). The key IEQ parameters considered in this study include thermal comfort, indoor air quality and visual comfort. These parameters have been measured by comfort-sense system, indoor air quality meter and light meter respectively. The measured data are integrated with BIM model in order to track the IEQ problems, and to develop IEQ history over time. By using the proposed framework, the IEQ can be tracked and improved. The IEQ assessment framework has been implemented on educational building in Saudi Arabia as a case study to validate the process and perform the necessary modifications and improvements.
文摘Daylighting studies in buildings are key parts of environmental analysis and can be easily conducted at the early stages of design as part of environmentally responsive building design as well as to inform the final architectural layout and interior design. The main aim of this study is to demonstrate how such daylighting studies can be completed at the early stages of design and, at the same time, to show the impact of window design and positioning on building indoor environments. The paper is focused on a study of window influence on room daylighting in residential buildings and computer lighting simulations in software packages: Windows Daylighting System and Autodesk Ecotect Analysis, have been carried out for different style and positioning of windows using several case studies. The main findings clearly indicated that not only the window size and style matters, but also the positioning of windows considering external walls which would make a significant influence on room daylighting levels and, therefore, such daylight studies are very important for the early stage of environmental analysis during building design.