The properties of anti-seismic HRB400 steel bars with 25 mm diameter were systematically investigated. The results showed that the properties of the HRB400 reinforced steel bars had been greatly enhanced comparing wit...The properties of anti-seismic HRB400 steel bars with 25 mm diameter were systematically investigated. The results showed that the properties of the HRB400 reinforced steel bars had been greatly enhanced comparing with HRB335 steel bars, i.e. coordination of strength and ductility, strain-aging sensibility, low temperature impact toughness, weld ability and high strain low cycle fatigue. The ductile-brittle transit temperatures of hot-rolled and strain-aged steel bars were evaluated as –17 °C and ?8 °C respectively, and the low temperature impact toughness of HRB400 steel bars remains to be improved. Transmission electron microscopy (TEM) and electron diffraction showed little vanadium existed in ferrite as VN, most of which existed in pearlite as alloy cementite which resulted in the declination of impact toughness. Methods were suggested to improve the anti- seismic properties of steel bars.展开更多
Based on a shaking table experiment of 1 :25 scale frame-shearwall structure model with steel transfer trusses,the dynamic characteristics,seismic responses in elastic and elastic-plastic phases with de- structive for...Based on a shaking table experiment of 1 :25 scale frame-shearwall structure model with steel transfer trusses,the dynamic characteristics,seismic responses in elastic and elastic-plastic phases with de- structive forms of the structure were studied.It was observed that cracks were developed with earthquake wave acceleration increasing,but no severe crack was developed in the structure during the experiment.In the seismic responses caused by artificial wave,site wave and E1 Centro wave,that caused by the artificial wave is the most intense one.Displacement angle between steel transfer trusses is large,which means the transfer stories might be weak.However,the seismic performance of the steel transfer trusses is good and the overall structure can satisfy seismic fortification requirements in the region of intensity 6.展开更多
In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the who...In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the whole structure. Obviously, it would be of special importance for the designer to know during the design process the extent of damage that the structure will suffer under the seismic action specified by the design spectrum and also the probability of occurrence of different states of behavior. The incremental nonlinear static analysis procedure used in this paper allows formulating a new, simplified, seismic damage index and damage thresholds associated with five limit states. The seismic behavior of a set of regular reinforced concrete buildings designed according to the EC-2/EC-8 prescriptions for a high seismic hazard level is then studied using the proposed damage index and damage states. Fragility curves and damage probability matrices corresponding to the performance point are calculated for the studied buildings. The obtained results show that the collapse damage state is not reached in the buildings designed according to the prescriptions of EC-2/EC-8 and also that the damage does not exceed the irreparable damage limit state.展开更多
Experience from recent earthquakes such as Gilan, Zanjan, Bam and Lorestan earthquakes in Iran indicated that the constructed buildings are vulnerable against earthquake. Vulnerability of these structures is due to va...Experience from recent earthquakes such as Gilan, Zanjan, Bam and Lorestan earthquakes in Iran indicated that the constructed buildings are vulnerable against earthquake. Vulnerability of these structures is due to various reasons such as designing without considering seismic regulations, problems of regulations (design goals), implementation problems, changing of the building occupancy class, increasing the weight of building stories, adding new stories to the building and changing in architecture of building without considering structural system. So the main objective of this research is to examine the features of building configuration and their effects as for the damages to buildings in past earthquakes. For this purpose, initially four occurred earthquakes in Iran are selected as case study. Then three types of buildings (steel structure, concrete structure and masonry buildings) are analyzed with details. Results showed that the most of damages are occurred in the old steel structures and masonry buildings which their ages are more than 25 years. The study showed that most of the buildings in the study area are steel structure and masonry buildings while concrete structures are infrequent which most of them had no or slight damages. Therefore, the importance and need to enhance the performance of available buildings against earthquake forces by rehabilitating methods would be more important than before. Also results indicated that the decisions related to architectural plan which have significant effect on seismic performance of buildings, can be divided into three categories: configuration of building, restrictive formal architectural plan and dangerous structural components, as these categories are not obstacle of each other, it is possible that each category has an influential effect on others. So organizing the design decisions in this way is very important so as to manage their effects and interdependencies.展开更多
The paper set up 3D solid overall superstructure model of Foundation and Box foundation on Rock Slope Subgrade base using the ABAQUS, and the establish the infinite element boundary, superstructure displacement of Box...The paper set up 3D solid overall superstructure model of Foundation and Box foundation on Rock Slope Subgrade base using the ABAQUS, and the establish the infinite element boundary, superstructure displacement of Box foundation and foundation at Rock Slope Subgrade was studied by inputting different direction of earthquake response. The results show that, for the mountain frame structure, influence on the horizontal displacement of the vertical under the action of alone big earthquake, and vertical seismic action on horizontal displacement effect is smaller by mutual function of horizontal and vertical seismic, basically is same as response under the action of horizontal earthquake alone; for step shaped box foundation, the change trend of mutual function of horizontal and vertical earthquake was the complete opposite of the maximum story drift each layer under the one-way horizontal earthquake, which indicate the presence of vertical earthquake wave effect on the box foundation displacement cannot be ignored.展开更多
An ongoing project at McGill University is aimed at developing an adapted seismic screening method for schools in the province of Qu6bec, Canada. As part of this project the "FEMA 154 Rapid Visual Screening of Buildi...An ongoing project at McGill University is aimed at developing an adapted seismic screening method for schools in the province of Qu6bec, Canada. As part of this project the "FEMA 154 Rapid Visual Screening of Buildings for Potential Seismic Hazard" and the "NRC92 Manual for Screening of Buildings for Seismic Investigation" were used to assess 102 school buildings located in the city of Montr6al. Results for both methods are in reasonable agreement, with 65% of the buildings requiring a detailed evaluation according to FEMAI54 and 50% according to NRC92. Findings highlighted the particular characteristics of educational facilities: they are low rise buildings with high incidence of structural irregularities. Accounting for them in the screening phase is essential, and is better achieved by NRC92. However, this method is largely based on expert opinion, which makes it difficult to update, while FEMA154 uses a rational methodology for calculating vulnerability scores based on the capacity spectrum approach. The FEMA154 analytical procedure allows updating and adapting the method to its use outside its intended scope.展开更多
In recent years the application of friction-based passive energy dissipation devices have been proven very effective in reducing structural response to earthquake excitations and also implemented for a large number of...In recent years the application of friction-based passive energy dissipation devices have been proven very effective in reducing structural response to earthquake excitations and also implemented for a large number of buildings. Their design heavily relies on numerical simulations to model the influence of the energy dissipation devices. The modeling of friction forces must be accurate for realistic simulation of the influence of these devices. In state-of-the-practice, the hysteretic behavior of friction devices has been typically modeled with Coulomb friction having a constant coefficient of friction. However, the basic laws for typical sliding materials and experimental investigations show non-linear relationship between friction and sliding velocity, which includes stiction and Stribeck effect. The influence of stiction and Stribeck effect may be significant and can not be ignored in simulating the dynamic responses of structures with friction-based energy dissipation devices. In this paper the optimal performance of dry friction device in shear-frame buildings when subjected to earthquake ground motions has been investigated. The focus of this paper is on the optimal minimization of response of the shear-frame building. Since buildings with friction devices behave in a highly nonlinear manner, nonlinear response-history analysis considering comprehensive sliding friction models has been carried out. The performance has also been evaluated using the various response measures: the maximum absolute acceleration, the maximum base shear, and the maximum inter-story drift. Different performance indices have been used to quantify the influence of the device properties.展开更多
The seismic behaviors of an integral concreting frame, a light steel storey-adding frame and a storeyadding frame strengthened with carbon fiber reinforced polymer(CFRP)were investigated under low-cycle and repeated l...The seismic behaviors of an integral concreting frame, a light steel storey-adding frame and a storeyadding frame strengthened with carbon fiber reinforced polymer(CFRP)were investigated under low-cycle and repeated load(scale 1∶3). The failure characteristics, hysteretic behavior, rigidity degeneracy, deflection ductility and energy-dissipation capacity of the three specimens were compared. The test results reveal that chemicallybonded rebar technique can meet the requirements of storey-adding engineering. The carrying capacity, the deflection ductility, the energy-dissipating capacity and seismic performance of the light steel storey-adding frame are higher than those of the integral concreting frame, and they are the highest in the storey-adding frame strengthened with CFRP.展开更多
文摘The properties of anti-seismic HRB400 steel bars with 25 mm diameter were systematically investigated. The results showed that the properties of the HRB400 reinforced steel bars had been greatly enhanced comparing with HRB335 steel bars, i.e. coordination of strength and ductility, strain-aging sensibility, low temperature impact toughness, weld ability and high strain low cycle fatigue. The ductile-brittle transit temperatures of hot-rolled and strain-aged steel bars were evaluated as –17 °C and ?8 °C respectively, and the low temperature impact toughness of HRB400 steel bars remains to be improved. Transmission electron microscopy (TEM) and electron diffraction showed little vanadium existed in ferrite as VN, most of which existed in pearlite as alloy cementite which resulted in the declination of impact toughness. Methods were suggested to improve the anti- seismic properties of steel bars.
文摘Based on a shaking table experiment of 1 :25 scale frame-shearwall structure model with steel transfer trusses,the dynamic characteristics,seismic responses in elastic and elastic-plastic phases with de- structive forms of the structure were studied.It was observed that cracks were developed with earthquake wave acceleration increasing,but no severe crack was developed in the structure during the experiment.In the seismic responses caused by artificial wave,site wave and E1 Centro wave,that caused by the artificial wave is the most intense one.Displacement angle between steel transfer trusses is large,which means the transfer stories might be weak.However,the seismic performance of the steel transfer trusses is good and the overall structure can satisfy seismic fortification requirements in the region of intensity 6.
文摘In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the whole structure. Obviously, it would be of special importance for the designer to know during the design process the extent of damage that the structure will suffer under the seismic action specified by the design spectrum and also the probability of occurrence of different states of behavior. The incremental nonlinear static analysis procedure used in this paper allows formulating a new, simplified, seismic damage index and damage thresholds associated with five limit states. The seismic behavior of a set of regular reinforced concrete buildings designed according to the EC-2/EC-8 prescriptions for a high seismic hazard level is then studied using the proposed damage index and damage states. Fragility curves and damage probability matrices corresponding to the performance point are calculated for the studied buildings. The obtained results show that the collapse damage state is not reached in the buildings designed according to the prescriptions of EC-2/EC-8 and also that the damage does not exceed the irreparable damage limit state.
文摘Experience from recent earthquakes such as Gilan, Zanjan, Bam and Lorestan earthquakes in Iran indicated that the constructed buildings are vulnerable against earthquake. Vulnerability of these structures is due to various reasons such as designing without considering seismic regulations, problems of regulations (design goals), implementation problems, changing of the building occupancy class, increasing the weight of building stories, adding new stories to the building and changing in architecture of building without considering structural system. So the main objective of this research is to examine the features of building configuration and their effects as for the damages to buildings in past earthquakes. For this purpose, initially four occurred earthquakes in Iran are selected as case study. Then three types of buildings (steel structure, concrete structure and masonry buildings) are analyzed with details. Results showed that the most of damages are occurred in the old steel structures and masonry buildings which their ages are more than 25 years. The study showed that most of the buildings in the study area are steel structure and masonry buildings while concrete structures are infrequent which most of them had no or slight damages. Therefore, the importance and need to enhance the performance of available buildings against earthquake forces by rehabilitating methods would be more important than before. Also results indicated that the decisions related to architectural plan which have significant effect on seismic performance of buildings, can be divided into three categories: configuration of building, restrictive formal architectural plan and dangerous structural components, as these categories are not obstacle of each other, it is possible that each category has an influential effect on others. So organizing the design decisions in this way is very important so as to manage their effects and interdependencies.
文摘The paper set up 3D solid overall superstructure model of Foundation and Box foundation on Rock Slope Subgrade base using the ABAQUS, and the establish the infinite element boundary, superstructure displacement of Box foundation and foundation at Rock Slope Subgrade was studied by inputting different direction of earthquake response. The results show that, for the mountain frame structure, influence on the horizontal displacement of the vertical under the action of alone big earthquake, and vertical seismic action on horizontal displacement effect is smaller by mutual function of horizontal and vertical seismic, basically is same as response under the action of horizontal earthquake alone; for step shaped box foundation, the change trend of mutual function of horizontal and vertical earthquake was the complete opposite of the maximum story drift each layer under the one-way horizontal earthquake, which indicate the presence of vertical earthquake wave effect on the box foundation displacement cannot be ignored.
文摘An ongoing project at McGill University is aimed at developing an adapted seismic screening method for schools in the province of Qu6bec, Canada. As part of this project the "FEMA 154 Rapid Visual Screening of Buildings for Potential Seismic Hazard" and the "NRC92 Manual for Screening of Buildings for Seismic Investigation" were used to assess 102 school buildings located in the city of Montr6al. Results for both methods are in reasonable agreement, with 65% of the buildings requiring a detailed evaluation according to FEMAI54 and 50% according to NRC92. Findings highlighted the particular characteristics of educational facilities: they are low rise buildings with high incidence of structural irregularities. Accounting for them in the screening phase is essential, and is better achieved by NRC92. However, this method is largely based on expert opinion, which makes it difficult to update, while FEMA154 uses a rational methodology for calculating vulnerability scores based on the capacity spectrum approach. The FEMA154 analytical procedure allows updating and adapting the method to its use outside its intended scope.
文摘In recent years the application of friction-based passive energy dissipation devices have been proven very effective in reducing structural response to earthquake excitations and also implemented for a large number of buildings. Their design heavily relies on numerical simulations to model the influence of the energy dissipation devices. The modeling of friction forces must be accurate for realistic simulation of the influence of these devices. In state-of-the-practice, the hysteretic behavior of friction devices has been typically modeled with Coulomb friction having a constant coefficient of friction. However, the basic laws for typical sliding materials and experimental investigations show non-linear relationship between friction and sliding velocity, which includes stiction and Stribeck effect. The influence of stiction and Stribeck effect may be significant and can not be ignored in simulating the dynamic responses of structures with friction-based energy dissipation devices. In this paper the optimal performance of dry friction device in shear-frame buildings when subjected to earthquake ground motions has been investigated. The focus of this paper is on the optimal minimization of response of the shear-frame building. Since buildings with friction devices behave in a highly nonlinear manner, nonlinear response-history analysis considering comprehensive sliding friction models has been carried out. The performance has also been evaluated using the various response measures: the maximum absolute acceleration, the maximum base shear, and the maximum inter-story drift. Different performance indices have been used to quantify the influence of the device properties.
基金Supported by the National Natural Science Foundation of China(No.51379142)
文摘The seismic behaviors of an integral concreting frame, a light steel storey-adding frame and a storeyadding frame strengthened with carbon fiber reinforced polymer(CFRP)were investigated under low-cycle and repeated load(scale 1∶3). The failure characteristics, hysteretic behavior, rigidity degeneracy, deflection ductility and energy-dissipation capacity of the three specimens were compared. The test results reveal that chemicallybonded rebar technique can meet the requirements of storey-adding engineering. The carrying capacity, the deflection ductility, the energy-dissipating capacity and seismic performance of the light steel storey-adding frame are higher than those of the integral concreting frame, and they are the highest in the storey-adding frame strengthened with CFRP.