An optimization method for time-delayed feedback control of partially observable linear building structures subjected to seismic excitation is proposed. A time-delayed control problem of partially observable linear bu...An optimization method for time-delayed feedback control of partially observable linear building structures subjected to seismic excitation is proposed. A time-delayed control problem of partially observable linear building structure under horizontal ground acceleration excitation is formulated and converted into that of completely observable linear structure by using separation principle. The time-delayed control forces are approximately expressed in terms of control forces without time delay. The control system is then governed by Itoe stochastic differential equations for the conditional means of system states and then transformed into those for the conditional means of modal energies by using the stochastic averaging method for quasi-Hamiltonian systems. The control law is assumed to be modal velocity feedback control with time delay and the unknown control gains are determined by the modal performance indices. A three-storey building structure is taken as example to illustrate the proposal method and the numerical results are confirmed by using Monte Carlo simulation.展开更多
A new control strategy based on modal energy criterion is proposed to demonstrate the effectiveness of the control system in reducing structural earthquake responses. The modal control algorithm combining LQR(linear q...A new control strategy based on modal energy criterion is proposed to demonstrate the effectiveness of the control system in reducing structural earthquake responses. The modal control algorithm combining LQR(linear quadratic regulator) control algorithm is adopted in the discrete time-history analysis. The various modal energy forms are derived by definition of the generalized absolute displacement vector. A preliminary numerical study of the effectiveness of this control strategy is carried out on a 20-storey framed steel structural model. The controlled performance of the model is studied from the perspectives of both response and modal energy. Results show that the modal energy-based control strategy is very effective in reducing structural responses as well as in consuming a large amount of modal energy,while augmentation of additional generalized control force corresponding to the modes that contain little modal energy is unnecessary,as it does little help to improve the controlled structural performance.展开更多
Severe vibration of underground structures may be induced under blast loads. According to the characteristics of the explosion-induced ground shock wave, a new-type damper, inverse control magneto-rheological(MR) da...Severe vibration of underground structures may be induced under blast loads. According to the characteristics of the explosion-induced ground shock wave, a new-type damper, inverse control magneto-rheological(MR) damper was designed to control the vibration, The high-frequency performance test of the MR damper was carried out on the small shaking table. It is shown that the performance can be modeled by use of the modified Bouc-Wen model, and the Parameters of the model keep stable in the range of 15--50 Hz.展开更多
Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipa...Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipation devices (EMF), a 5-story steel frame model with spacious first story is designed and made according to a scale of 1/4. The magnet-friction energy dissipation devices can realize continuously varied controlling force, with rapid response and reverse recognition. Therefore, they overcome shortcomings usually found in energy dissipation devices whose force models are invariable. The two kinds of devices were fixed on the flexible first story of the structure model, and the shaking table tests have been carried out, respectively. In these tests, the performance of the devices and their effectiveness in structural control were confirmed. In this paper, the test results and analysis are discussed.展开更多
The objective of this paper is to investigate the dynamic characteristics of two adjacent building structures interconnected by viscoelastic dampers under seismic excitations. The computational procedure for an analyt...The objective of this paper is to investigate the dynamic characteristics of two adjacent building structures interconnected by viscoelastic dampers under seismic excitations. The computational procedure for an analytical model including the system model formulation, complex modal analysis and seismic time history analysis is presented for this purpose. A numerical example is also provided to illustrate the analytical model. The complex modal analysis is conducted to determine the optimal damping ratio, the optimal damper stiffness and the optimal damper damping of the viscoelastic dampers for each mode of the system. For the damper stiffness and damping with optimal values, the responses can be categorized into underdamped and critically damped vibrations. Furthermore, compared to the viscous dampers with only the energy dissipation mechanism, the viscoelastic dampers with both the energy dissipation and redistribution mechanisms are more effective for increasing the damping ratio of the system. The seismic time history analysis is conducted to assess the effectiveness of the viscoelastic dampers for vibration control. Based on the optimal damping ratio, the optimal damper stiffness, the optimal damper damping of the viscoelastic dampers for a certain mode of the system, and the viscoelastic dampers can be used to effectively suppress the root-mean-square responses as well as the peak responses of the two adjacent buildings.展开更多
基金the National Natural Science Foundation of China (Nos. 10332030 and 10772159)the Research Fund for theDoctoral Program of Higher Education of China (No. 20060335125)
文摘An optimization method for time-delayed feedback control of partially observable linear building structures subjected to seismic excitation is proposed. A time-delayed control problem of partially observable linear building structure under horizontal ground acceleration excitation is formulated and converted into that of completely observable linear structure by using separation principle. The time-delayed control forces are approximately expressed in terms of control forces without time delay. The control system is then governed by Itoe stochastic differential equations for the conditional means of system states and then transformed into those for the conditional means of modal energies by using the stochastic averaging method for quasi-Hamiltonian systems. The control law is assumed to be modal velocity feedback control with time delay and the unknown control gains are determined by the modal performance indices. A three-storey building structure is taken as example to illustrate the proposal method and the numerical results are confirmed by using Monte Carlo simulation.
基金Project (No. G20050452) supported by the Education Bureau of Zhejiang Province, China
文摘A new control strategy based on modal energy criterion is proposed to demonstrate the effectiveness of the control system in reducing structural earthquake responses. The modal control algorithm combining LQR(linear quadratic regulator) control algorithm is adopted in the discrete time-history analysis. The various modal energy forms are derived by definition of the generalized absolute displacement vector. A preliminary numerical study of the effectiveness of this control strategy is carried out on a 20-storey framed steel structural model. The controlled performance of the model is studied from the perspectives of both response and modal energy. Results show that the modal energy-based control strategy is very effective in reducing structural responses as well as in consuming a large amount of modal energy,while augmentation of additional generalized control force corresponding to the modes that contain little modal energy is unnecessary,as it does little help to improve the controlled structural performance.
基金Supported by National Nature Fund and National Civil-Defense Office
文摘Severe vibration of underground structures may be induced under blast loads. According to the characteristics of the explosion-induced ground shock wave, a new-type damper, inverse control magneto-rheological(MR) damper was designed to control the vibration, The high-frequency performance test of the MR damper was carried out on the small shaking table. It is shown that the performance can be modeled by use of the modified Bouc-Wen model, and the Parameters of the model keep stable in the range of 15--50 Hz.
文摘Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipation devices (EMF), a 5-story steel frame model with spacious first story is designed and made according to a scale of 1/4. The magnet-friction energy dissipation devices can realize continuously varied controlling force, with rapid response and reverse recognition. Therefore, they overcome shortcomings usually found in energy dissipation devices whose force models are invariable. The two kinds of devices were fixed on the flexible first story of the structure model, and the shaking table tests have been carried out, respectively. In these tests, the performance of the devices and their effectiveness in structural control were confirmed. In this paper, the test results and analysis are discussed.
文摘The objective of this paper is to investigate the dynamic characteristics of two adjacent building structures interconnected by viscoelastic dampers under seismic excitations. The computational procedure for an analytical model including the system model formulation, complex modal analysis and seismic time history analysis is presented for this purpose. A numerical example is also provided to illustrate the analytical model. The complex modal analysis is conducted to determine the optimal damping ratio, the optimal damper stiffness and the optimal damper damping of the viscoelastic dampers for each mode of the system. For the damper stiffness and damping with optimal values, the responses can be categorized into underdamped and critically damped vibrations. Furthermore, compared to the viscous dampers with only the energy dissipation mechanism, the viscoelastic dampers with both the energy dissipation and redistribution mechanisms are more effective for increasing the damping ratio of the system. The seismic time history analysis is conducted to assess the effectiveness of the viscoelastic dampers for vibration control. Based on the optimal damping ratio, the optimal damper stiffness, the optimal damper damping of the viscoelastic dampers for a certain mode of the system, and the viscoelastic dampers can be used to effectively suppress the root-mean-square responses as well as the peak responses of the two adjacent buildings.